background image

1-866-933-7486 

Quest Power Electric Heat EHS 31

 Pro

 

Installation, Operation and Maintenance Instructions

  

7

www.QuestProtect.com

[email protected]

quest

quest

1

6

4

0

X

Y

    PART NO.          REV.

4033034       A

W

230 VAC

50/60 HZ, 1 Ph

(BLACK)

(RED)

1

0

4

6

Yellow

Low Voltage Schematic

High Voltage Schematic

Made in U.S.A

Therma-Stor LLC, Madison, WI 53708

800-533-7533 or Local 608-222-5301

www.thermastor.com

Blower

Capacitor

Blower

Relay

Heater

Blower

Brown

Transformer

5200 Watt

10 

Contactor 

#1

Contactor 

#2

Orange

Blue

50 AMP

Receptacle

Blue

Black

Red

Black

Black

3800 Watt

14 

Contactor #2

L1

Blue

Blower

Black

230 V

24 V

Optional

Thermostat

Master

Power Switch

Pressure

Switch

140°

Thermal 

Cut-Out

Hi/Low

Power

Switch

Blower Relay 

Coil

Hour

Meter

Contactor #2

Coil

Contactor #1

Coil

Transformer

Brown

Blower

Capacitor

Blower

Relay

L2

5200 Watt

Element

Contactor #1

3800 Watt

Element

Hi-Low

Power Switch

Blower Relay

Thermostat

Connection (Optional)

Brown

Transformer

Hour Meter

Master Power 

Switch

Yellow

Contactor 

#1

Contactor 

#2

140°

Thermal

Cut-Out

Pressure

Switch

Yellow

Yellow

Red

Red

Orange

Orange

Blue

Blue

Blue

Black

Black

1-3 Sec

Time

Delay

Orange

Red

Gray

Fuse

1A

1A

Fuse

Gray

6 Wiring Diagram

5 Options and Accessories

4024750 

12” x 25’ Intake Flex Duct

4024969 

16” x 20” x 2” Pleated Media MERV-8

4021475 

16” x 20” x 2” Standard Pleated Media MERV-11

4022164 

16” x 20” x 2” Optional Pleated Media MERV-14

4027326 

25’ 240V Cord Kit

4031045 

50’ 240V Cord Kit

4031046 

75’ 240V Cord Kit

4031047 

100’ 240V Cord Kit 

4030115 

Reed LM 8000 Multi-Meter

4033669 

12” Duct Collar

4027322 

Remote Thermostat

Summary of Contents for EHS 31 Pro

Page 1: ...space Quest Power Electric Heat EHS 31 Pro Listed by ETL to UL Safety Standards NEC Compliant 30 or 50 Amp operation 18 000 BTU 31 000 BTU 30 Amp 24 Actual Amp Draw and 46ºF Temperature Rise 50 Amp 40 Actual Amp Draw and 80ºF Temperature Rise Two 8 Power Cords 1 dryer 1 range included with unit Remote Thermostat with 25 connecting wire included with unit Multiple air filter options Standard MERV 1...

Page 2: ... Remote Thermostat Connection 5 3 Maintenance 5 3 1 Air Filter 5 4 Service 6 4 1 Technical Description 6 4 2 Troubleshooting 6 5 Options and Accessories 7 6 Wiring Diagram 7 7 Service Parts 8 8 Warranty 9 Serial No ___________________________ Purchase Date ______ ______ _____ Dealer s Name ___________________________________ Read the operation and maintenance instructions carefully before using th...

Page 3: ...an area where it may fall into a bathtub or other water container DO NOT run cord under carpeting or other floor covering Arrange cord away from traffic area and where it will not be tripped over To disconnect device turn controls off then remove plug from outlet Connect ONLY to properly grounded outlets DO NOT insert or allow foreign objects to enter any ventilation or exhaust openings as this ma...

Page 4: ...2 2 Electrical Requirements The Quest Power Electric Heat EHS 31 Pro requires 220 240VAC The Power Electric Heat EHS 31 Pro outlet is 240VAC with ground When properly installed it provides a ground connection through the cord to the heater to protect the operator from electric shock The Quest Power Electric Heat EHS 31 Pro comes equipped with two 8 long cords for connection to grounded residential...

Page 5: ...at wiring Connect one wire to each terminal If the Power Electric Heat EHS 31 Pro is placed inside the space to be heated place the thermostat on top of the unit For applications where the Power Electric Heat EHS 31 Pro is placed outside the space to be heated e g ducting heat into a chamber the 25 cord allows you to place the thermostat inside the heated space In addition to the included thermost...

Page 6: ... relays and contactors For safety there is an air pressure switch that will shut the heating elements off or prevent the heating elements from coming on if airflow is restricted at either the inlet or the outlet An additional safety switch limits the incoming air temperature to 140 F This switch shuts off the heating elements and automatically resets when the temperature falls to 130 F 4 2 Trouble...

Page 7: ...Hi Low Power Switch Blower Relay Coil Hour Meter Contactor 2 Coil Contactor 1 Coil Transformer Brown Blower Capacitor Blower Relay L2 5200 Watt Element Contactor 1 3800 Watt Element Hi Low Power Switch Blower Relay Thermostat Connection Optional Brown Transformer Hour Meter Master Power Switch Yellow Contactor 1 Contactor 2 140 Thermal Cut Out Pressure Switch Yellow Yellow Red Red Orange Orange Bl...

Page 8: ...4030614 5 Pressure Switch 1 4027305 6 Blower Relay 1 4022484 7 5mf Capacitor 1 4027315 8 Heating Element 1 4027317 9 Flanged 50A Inlet 1 4027308 10 Master Power Switch 1 4027331 11 Hour Meter 1 4028795 12 High Low Power Switch 1 4027330 13 Skidplate 1 4025691 14 Wheel 2 4025676 15 Foot 2 4024073 16 Delay Timer 1 4031099 17 1A Fuse 1 4033033 12 Duct Collar not shown 1 4033669 Remote Thermostat not ...

Page 9: ...orized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control Limitation and Exclusions If any Quest Power Electric Heat EHS 31 Pro part is repaired or replaced the new part shall be warranted for only the remainder of the original warranty period applicable thereto but all warranty periods will be extended by the period of time if...