Safety Precautions

Read the installation, operation and maintenance instructions carefully before installing and operating  
this device. Proper adherence to these instructions is essential to obtain maximum benefit from your  
Quest DRY 115. 

READ AND SAVE THESE INSTRUCTIONS 

The Quest DRY 115 can be installed in a variety of locations to 
meet the owner’s needs as listed below.  In all cases, keep the 
following cautions in mind:
•  The Quest DRY 115 is designed to be installed 

INDOORS ONLY.

•  If used near water, the unit should be plugged into GFCI circuits
• 

DO NOT use the Quest DRY 115 as a bench or table

•  Avoid discharging the process air directly at people
•  Reactivation outlet air MUST be discharged into a location that 

can tolerate high temperature, moist air.

•  If the reactivation outlet ductwork passes through a cold space, 

the duct must be insulated to prevent condensation from forming 
inside the duct.

The Quest DRY 115 supports multi-position operation and multiple 
ducting options.  In 

EVERY case the Reactivation Outlet air MUST 

be ducted out of the drying space and to a location tolerant of high 
temperature moist air (usually outside).

Summary of Contents for DRY 115

Page 1: ...0 Madison WI 53704 Toll Free 1 800 533 7533 www QuestProtect com sales QuestProtect com Read and Save These Instructions Specifications subject to change without notice TS 397 04 12 1 Quest DRY115 Quest DRY 115 Low dewpoint operation 115 Pints Day AHAM Wide operating range 22 Amps total power consumption Factory installed 115VAC power cords 2 required 15 Amps each Simple ON OFF operation with avai...

Page 2: ...tion 5 2 1 Electrical Requirements 5 2 2 Inside Drying Space with 5 Single Reactivation Outlet Duct 2 3 Inside Drying Space with 5 Isolated Reactivation Outlet Duct 2 4 Outside Drying Space 5 3 Operation 5 4 Maintenance 5 5 Wiring Diagram 6 6 Service Parts List 7 Warranty 8 Serial No __________________________________ Purchase Date ______________________________ Dealer s Name _____________________...

Page 3: ...following cautions in mind The Quest DRY 115 is designed to be installed INDOORS ONLY If used near water the unit should be plugged into GFCI circuits DO NOT use the Quest DRY 115 as a bench or table Avoid discharging the process air directly at people Reactivation outlet air MUST be discharged into a location that can tolerate high temperature moist air If the reactivation outlet ductwork passes ...

Page 4: ...vation Duct 6 Start collars included Process Duct 8 Start collars included Range 10 F to 140 F Warranty 1 Year Parts and Labor Low temperature performance is dependent on reactivation air source Supplying warmer reactivation air will significantly increase water removal Dimensions Unit Shipping Width 20 25 Height 36 47 Depth 20 24 Weight 105 Lb 125 Lb Accessories 4026859 6 Metalized Polyester Flex...

Page 5: ... be ducted out of and back into drying space Works well if drying space is too small for mounting unit inside Reduces heat load on drying space 3 Operation The Quest DRY 115 comes complete and can be plugged in and turned on Connected this way the Quest DRY 115 will run continuously With the addition of a high or low voltage humidistat or a duty cycle timer the ON OFF switch will act as an overrid...

Page 6: ...1 800 533 7533 Quest DRY 115 Installation Operation and Maintenance Instructions 6 www QuestProtect com sales QuestProtect com quest quest 5 Wiring diagram ...

Page 7: ...SKID 18 4032315 CORD 2 PLACES Not 4026922 GASKET AND BELT REPLACEMENT KIT Shown 16 15 18 1 800 533 7533 Quest DRY 115 Installation Operation and Maintenance Instructions www thermastor com sales questprotect com quest Asset Protection and IAQ Solutions quest 9 0 8 5 6 Service Parts List Item Part No Description 1 4025076 FAN MOTORIZED IMPELLER PROCESS AIR 2 4025224 CAPACITOR RUN 15 MFD 370V DRY PR...

Page 8: ...reezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC reasonable control Limitations and Exclusions If any Quest DRY 115 Dehumidifier part is repaired or replaced the new part shall be warranted for only the remainder of the original warranty period applicable thereto but all warranty periods will be extende...

Reviews: