connectors to connect the 4 wires from the remote sensor to the user-supplied interconnect wire. Be sure to keep
proper colors attached to each other.
3. Sensor mounting:
You will need two screws to mount the sensor. Use the two slotted holes to mount the base of the sensor to the
wall and then snap the cover into place.
4. Controller connection:
Use the provided splice connectors to connect the 4 wires from the DEH 3000R to the user-supplied interconnect
wire. Be sure to keep the proper colors attached to each other.
Continue with the installation as described in the rest of this manual.
2.5 Control Panel Wiring Instructions
WARNING!
DO NOT ALLOW THE YELLOW WIRE FROM THE QUEST DEHUMIDIFIER
TO CONTACT THE RED OR WHITE WIRES FROM THE QUEST DEHUMIDIFIER, DAMAGE TO THE 24-VOLT
TRANSFORMER WILL RESULT.
WARNING!
THE QUEST DEH 3000R DIGITAL CONTROL OPERATES ON A LOW
VOLTAGE CIRCUIT (24 VAC) AND MUST NEVER CONTACT OR BE CONNECTED TO A HIGH VOLTAGE
CIRCUIT.
WARNING!
UNPLUG THE QUEST DEHUMIDIFIER BEFORE WIRING THE DEH 3000R.
The installer must supply all field wiring, including the wiring between the QUEST dehumidifier and
the Quest DEH 3000R. Some of the control wires leaving the QUEST dehumidifier may not be used
in some control situations and should be left disconnected with wire nuts taped onto the stripped
ends.
Be sure to consult the electrical schematic in this manual or the internal electrical box of the Quest
dehumidifier before making any control connections.
WARNING!
ONLY CONNECT THE WHITE WIRE TO THE CONTROL IF IT IS WIRED IN A
CIRCUIT THROUGH AN ELECTRIC DAMPER, OTHERWISE TRANSFORMER DAMAGE MAY RESULT.