1. Intended Application for Quest 70
The Quest 70 is designed to operate in temperatures between 5°C and 35°C.
In order to efficiently control humidity levels, the area in which the dehumidifier is to be operated must be free of water
intrusion or excessive fresh (outside) air infiltration. Before installing the Quest 70, water intrusion and air infiltration
problems should be addressed.
2. Registrations
The Quest 70 conforms to CE standards.
3. Specifications @ 26.7°C/60%RH
4033810-XX Quest 70
Blower:
150 CFM @ 0.0" WG
Power: (Watts)
480
Supply voltage:
230 VAC - 1 Phase - 50 Hz.
Current Draw: (Amps)
2.1
Energy Factor: (K/kWh)
2.22
Operating Temp:
5°C to 35°C
Water Removal: (L/Day)
26
Air Filter: MERV-13
Size: 23cm x 28cm x 3cm
Drain Connection:
3/4” Threaded NPT
Refrigeration Type:
Refrigerant Amount:
R410A
15oz.
Dimensions:
Width:
Height:
Length:
Weight:
Unit
31cm
31cm
54cm
25 kg
Power Cord:
20’ Fem IEC 60320-C13
4033810-01 UK Cord
BS 1363 (type G)
4033810-02 AUS Cord
AS 3112 (type I)
4033810-03 EU Cord
CEE 7/7 (type E and F)