1. Intended Application for Quest 155
The Quest 155 is designed to operate in temperatures between 5°C and 35°C.
In order to efficiently control humidity levels, the area in which the dehumidifier is to be operated must be free of water
intrusion or excessive fresh (outside) air infiltration. Before installing the Quest 155, water intrusion and air infiltration
problems should be addressed.
2. Registrations
The Quest 155 conforms to CE standards.
3. Specifications @ 26.7°C/60% RH
4037400-XX Quest 155
Blower:
415 CFM @ 0.0" WG
Power: (Watts)
800
Supply voltage:
230 VAC - 1 Phase - 50 Hz.
Current Draw: (Amps)
3.5
Energy Factor: (L/kWh)
3.74
Operating Temp:
5°C Min - 35°C Max
Water Removal: (L/Day)
71
Air Filter: MERV-13
Size: 41cm x 51cm x 5cm
Drain Connection:
3/4” Threaded NPT
Refrigeration Type:
Refrigerant Amount:
R410A
2 lbs, 1 oz
Dimensions:
Width:
Height:
Length:
Weight:
Unit
96cm
56cm
51cm
61 kg
Power Cord:
20’ Fem IEC 60320-C13
4037400-01 UK Cord
BS 1363 (type G)
4037400-02 AUS Cord
AS 3112 (type I)
4037400-03 EU Cord
CEE 7/7 (type E and F)