Quest 150 Dual Dehumidifier Limited Warranty 

WARRANTOR: 
Therma-Stor LLC 

4201 Lien Rd 

Madison, WI 53704 

Telephone: 1-800-533-7533
WHO IS COVERED: This warranty extends only to the original end-user of the Quest 150 Dual dehumidifier, and may 

not be assigned or transferred.
FIRST YEAR WARRANTY: Therma-Stor LLC warrants that, for one (1) year the Quest 150 Dual dehumidifier will 

operate free from any defects in materials and workmanship, or Therma-Stor LLC will, at its option, repair or replace the 

defective part(s), free of any charge.
SECOND THROUGH FIFTH YEAR WARRANTY: Therma-Stor LLC further warrants that for a period of five (5) 

years, the condenser, evaporator, and compressor of the Quest 150 Dual dehumidifier will operate free of any defects in 

material or workmanship, or Therma-Stor LLC, at its option, will repair or replace the defective part(s), provided that all 

labor and transportation charges for the part(s) shall be borne by the end-user.
END-USER RESPONSIBILITIES: Warranty service must be performed by a Servicer authorized by Therma-Stor LLC. 

If the end-user is unable to locate or obtain warranty service from an authorized Servicer, he should call Therma-Stor 

LLC at the above number and ask for the Therma-Stor LLC Service Department, which will then arrange for covered 

warranty service. Warranty service will be performed during normal working hours.
The End-user must present proof of purchase (lease) upon request, by use of the warranty card or other reasonable and 

reliable means. The end-user is responsible for normal care. This warranty does not cover any defect, malfunction, etc. 

resulting from misuse, abuse, lack of normal care, corrosion, freezing, tampering, modification, unauthorized or improper 

repair or installation, accident, acts of nature or any other cause beyond Therma-Stor LLC's reasonable control.
LIMITATIONS AND EXCLUSIONS: If any Quest 150 Dual Dehumidifier part is repaired or replaced, the new part 

shall be warranted for only the remainder of the original warranty period applicable thereto (but all warranty periods will 

be extended by the period of time, if any, that the Quest 150 Dual Dehumidifier is out of service while awaiting covered 

warranty service).
UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE Quest 150 Dual 

DEHUMIDIFIER OR ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, INCLUDING 

MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. ALL 

WARRANTIES MADE BY THERMA-STOR LLC ARE SET FORTH HEREIN, AND NO CLAIM MAY BE MADE 

AGAINST THERMA-STOR LLC BASED ON ANY ORAL WARRANTY. IN NO EVENT SHALL THERMA-STOR 

LLC, IN CONNECTION WITH THE SALE, INSTALLATION, USE, REPAIR OR REPLACEMENT OF ANY Quest 

150 Dual DEHUMIDIFIER OR PART THEREOF BE LIABLE UNDER ANY LEGAL THEORY FOR ANY SPECIAL, 

INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION WATER DAMAGE (THE 

END-USER SHOULD TAKE PRECAUTIONS AGAINST SAME), LOST PROFITS, DELAY, OR LOSS OF USE OR 

DAMAGE TO ANY REAL OR PERSONAL PROPERTY.
Some states do not allow limitations on how long an implied warranty lasts, and some do not allow the exclusion or 

limitation of incidental or consequential damages, so one or both of these limitation may not apply to you.
LEGAL RIGHTS: This warranty gives you specific legal rights, and you may also have other rights which vary from state 

to state.

Summary of Contents for 150 Dual

Page 1: ...nd function Installation Operation and Maintenance Instructions 4201 Lien Rd Phone 608 237 8400 Madison WI 53704 Toll Free 1 877 420 1330 www QuestClimate com info QuestClimate com Read and Save These...

Page 2: ...Compressor Shipping Support 5 4 2 Location 5 4 2A How to hang dehumidifier 5 4 3 Electrical Requirements 6 4 4 Install Leveling Feet 6 4 5 Condensate Water Removal 7 5 Ducting 8 5 1 Outlet Duct Kit 8...

Page 3: ...or maintenance and service DO NOT INSTALL UNIT WITH THE SERVICE PANELS INACCESSIBLE Avoid directing the discharge air at people or over the water in pool areas If used near a pool or spa be certain th...

Page 4: ...trusion or excessive fresh outside air infiltration Before installing the Quest 150 Dual water intrusion and air infiltration problems should be addressed 2 Registrations The Quest 150 Dual units conf...

Page 5: ...be installed in a variety of locations to meet the owner s needs other considerations include 1 Providing access to a 115 VAC power outlet 10 power cord is provided 2 Locating near a floor or other s...

Page 6: ...ed with your Quest 150 Dual are four leveling feet It is important to level the unit for proper draining Installing Leveling Feet See Figure 2 for installing leveling feet 1 Lay down a protective pad...

Page 7: ...er out of the corners of the machine Position the trap in the hose approximately 8 10 from the dehumidifier and make sure the highest point of the trap is still at least 2 below the black drain port a...

Page 8: ...umid 80 to 90 Relative Humidity The dehumidifier will run until the relative humidity RH is reduced to the humidity control dial setting Quality humidity meters are available from the factory and are...

Page 9: ...esult in death serious bodily injury and or property damage Only qualified service people should service this unit CAUTION If the supply cord is damaged it must be replaced by the manufacturer its ser...

Page 10: ...ssor run with fan switch AUTO 1 Unit unplugged or no power to outlet circuit breaker tripped 2 Humidity control set to Humid setting 3 Loose connection in internal wiring 4 Humidity control is defecti...

Page 11: ...fly but cycles on and off 1 Loose connection in blower circuit 2 Obstruction prevents impeller rotation 3 Defective blower 4 Defective blower switch Evaporator coil frosted continuously low dehumidify...

Page 12: ...eller 4033032 06 50mfd 370V Capacitor Compressor 4035235 10 12mfd 370V Capacitor Impeller 4026221 Leveling Foot 4031376 Defrost Thermostat 4027172 Humidity Controller 4025560 Fan Switch 4036568 Bracke...

Page 13: ...13 www QuestClimate com info QuestClimatecom 11 Wiring Diagram 115 VAC 60 Hz SINGLE PHASE BLK BLK BLU WHT GRN GRN YEL RED FAN SWITCH DEFROST THERMOSTATS IMPELLER COMPRESSOR 3 1 2 BLK BLK ORG S C R GRN...

Page 14: ...ans The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauth...

Reviews: