3. Troubleshooting Guide
NOTE: If at any time your alarm fails to operate correctly (erratic or low sound, for example), or if you require further
information, please contact customer support at 1800 654 435.
Trouble Condition Visual Indications
Audible Indications
Action:
Low Battery
Amber LED blinks every
60 sec.
Model Q7DCO digital
display will show “Lb”.
Chirp every 60 sec.
* Push test button once to silence for 24 hrs.
Note: 30 days after Low Battery begins, the
* Replace batteries as soon as possible.
Fault Mode
Amber LED blinks every
30 sec.
Model Q7DCO digital
display will show “Err”.
Chirp every 30 sec.
* See Cleaning Your Alarm section.
* Push test button once to attempt to reset
the unit.
End of Unit Life
Amber LED blinks twice
every 60 sec.
Model Q7DCO digital
display will show “End”.
Two chirps every
60 sec.
* Push button once to silence for 24 hrs.
Note: 30 days after End of Unit Life begins, the
* Remove, dispose unit, and replace as soon
as possible.
MCU Failure
None.
Constant tone.
* Replace alarm.
Stuck Button
Amber LED blinks
every 5 sec.
Chirp every 5 sec.
* Push button to dislodge it from being stuck.
If button cannot be unstuck, remove, dispose
unit, and replace as soon as possible.
3. Troubleshooting Guide