3.8. Serial interfaces
The module provides three unbalanced asynchronous serial ports including UART, Debug Port
and UART3.The module is designed as a DCE (Data Communication Equipment), following the
traditional DCE-DTE (Data Terminal Equipment) connection. Autobauding function supports
baud rate from 4800bps to 115200bps.
The UART Port:
TXD: Send data to RXD of DTE
RXD: Receive data from TXD of DTE
RTS: Requests to send
CTS: Clear to send
DTR: DTE is ready and inform DCE (this pin can wake the module up)
RI: Ring indicator (when the call, SMS, data of the module are coming, the module will
output signal to inform DTE)
DCD: Data carrier detection (The validity of this pin demonstrates the communication link is
set up)
Note: The module disables hardware flow control by default. When hardware flow control is
required, RTS and CTS should be connected to the host. AT command “AT+IFC=2,2” is used
to enable hardware flow control. AT command “AT+IFC=0,0” is used to disable the hardware
flow control. For more details, please refer to document [1].