6.3. Operation and Storage Temperatures
The operation and storage temperatures of the module are listed in the following table.
Table 33: Operation and Storage Temperatures
1.
1)
Within
operation temperature range, the module is 3GPP compliant.
2.
2)
Within extended temperature range, the module remains the ability to establish and maintain a
voice, SMS, data transmission, emergency call, etc. There is no unrecoverable malfunction. There
are also no effects on radio spectrum and no harm to radio network. Only one or more parameters
like P
out
might reduce in their value and exceed the specified tolerances. When the temperature
returns to the normal operating temperature levels, the module will meet 3GPP specifications again.
6.4. Current Consumption
The following table shows current consumption of BG96 module.
Table 34: BG96 Current Consumption
USB_VBUS
USB detection
3.0
5.0
5.25
V
Parameter
Min.
Typ.
Max.
Unit
Operation Temperature Range
1)
-35
+25
+75
ºC
Extended Temperature Range
2)
-40
+85
ºC
Storage Temperature Range
-40
+90
ºC
Parameter Description
Conditions
Typ.
1)
Unit
I
VBAT
Leakage
Current
Power off mode
8
uA
PSM
Power Saving Mode @Real Network
10
uA