GV300CAN User Manual
TRACGV300CANUM001
- 18 -
Figure 1
3
.
Typical Connection with Relay
Figure 1
4
.
Typical Connection with LED
Note:
1. OUT1 will latch the output state during reset.
2. Many modern relays come with a flyback
diode pre-installed internal to the relay itself. If the
relay has this diode, ensure the relay polarity is properly connected. If this diode is not internal, it
should be added externally. A common diode such as a 1N4004 will work in most circumstances.