GL300 @Tracker Air Interface Protocol
End time
4
HHMM
0000
Check interval
<=5
5 – 86400sec
180
Send interval
<=5
5 – 86400sec
180
Ignition Check interval
<=5
5 – 86400sec
180
Ignition Send interval
<=5
5 – 86400sec
180
Report mask
<=4
0000 – FFFF
1F
Distance
<=5
50 – 65535m
1000
Mileage
<=5
50 – 65535m
1000
movement detect mode
1
0|1
0
movement speed
<=3
1-999(km/h)
5
movement distance
<=4
1-9999(m)
50
movement send
number
1 1-5
5
corner
3
0 - 180
0
Reserved 0
GEO
3
GEO
GEO
GEO ID0
1
0
0
Mode
1
0 – 3
0
Longitude <=11
±xxx.xxxxxx
0.00000
Latitude <=10
±xx.xxxxxx
0.00000
Radius
<=7
50 – 6000000m
50
Check interval
<=5
0|30 – 86400sec
0
State mode
1
0|1
0
Reserved 0
Reserved 0
Reserved 0
Reserved 0
Reserved 0
Reserved 0
Reserved 0
GEO ID1
1
1
1
Mode
1
0 – 3
0
Longitude <=11
±xxx.xxxxxx
0.00000
Latitude <=10
±xx.xxxxxx
0.00000
Radius
<=7
50 – 6000000m
50
Check interval
<=5
0|30 – 86400sec
0
State mode
1
0|1
0
Reserved 0
Reserved 0
Reserved 0
Reserved 0
Reserved 0
TRACGL300AN001
- 61 -
Queclink
Confidential