background image

GB100MG User Manual

   

TRACGB100MGLSUM001

   

- 13 -

3.5.

 

LED Status 

Table 4

Definition of Device status and LED 

LED

 

Device status 

LED status 

LED 

Working Normally 

Continuous on 

PDP not activated 

One flashing: 100ms On, 2s 0f 

Network not registered or SIM card not inserted 

Two  flashing:  100ms  On,  500ms  Off, 
100ms On, 2s Off... 

GNSS not fixed 

Three  flashing:  100ms  On,  500ms  off, 
100ms On, 500ms Off, 100ms On, 2s off.. 

PDP not activated and GNSS not fixed 

One  flashing  +  Three  flashing:  100ms 
On, 2s off, 100ms On, 500ms off, 100ms 
On, 500ms off, 100ms On, 2s off... 

Network not registered or SIM card not inserted and 
GNSS not fixed   

Two fl Three flashing: 100ms On, 
500ms  Off,  100ms  On,  2s  Off  100ms  On, 
500ms  off,  100ms  On,  500ms  off,  100ms 
On, 2s off... 

Device power off or sleep mode 

Extinguished 

Figure 7. GB100MG Lite LED on the case 

Queclink 

Summary of Contents for GB100MG Lite

Page 1: ...GPS Tracker GB100MG Lite User Manual TRACGB100MGLSUM001 Version R1 00 GB100MG Lite...

Page 2: ...may be in the customer s possession Furthermore system validation of this product designed by Queclink within a larger electronic system remains the responsibility of the customer or the customer s s...

Page 3: ...Reference 6 2 Product Overview 7 2 1 Check Part List 7 2 2 Part List 8 2 3 Interface Definition 8 3 Getting Started 9 3 1 Opening the Case 9 3 2 Closing the case 10 3 3 Installing SIM card 11 3 4 Powe...

Page 4: ...MG Lite User Manual TRACGB100MGLSUM001 3 Table Index TABLE 1 GB100MG LITE PROTOCOL REFERENCE 6 TABLE 2 PART LIST 8 TABLE 3 DESCRIPTION OF 2 PIN POWER CABLE 8 TABLE 4 DEFINITION OF DEVICE STATUS AND LE...

Page 5: ...EARANCE OF GB100MG LITE 7 FIGURE 2 GB100MG LITE 2 PIN POWER CABLE 8 FIGURE 3 OPENING THE CASE 9 FIGURE 4 CLOSING THE CASE 10 FIGURE 5 INSTALLING SIM CARD 11 FIGURE 6 TYPICAL POWER CONNECTION 12 FIGURE...

Page 6: ...GB100MG User Manual TRACGB100MGSUM001 5 0 Revision History Revision Date Author Description of change 1 00 2019 12 04 Young Chen Initial...

Page 7: ...1 and Cat NB1 allow the GB100MG Lite location to be monitored in real time or periodically tracked by a backend server and mobile devices Its built in 3 axis accelerometer allows motion detection 100...

Page 8: ...00MGSUM001 7 2 Product Overview 2 1 Check Part List Before starting check all the following items have been included with your GB100MG Lite If anything is missing please contact your supplier Figure 1...

Page 9: ...100MG Lite Locator 2 3 Interface Definition The GB100MG Lite has a 2 PIN power cable The pin definition of the 2 pin power cable as below Table 3 Description of 2 PIN Power Cable Index Description Com...

Page 10: ...100MG User Manual TRACGB100MGSUM001 9 3 Getting Started 3 1 Opening the Case Take out the 6pcs screws from the device and push the opener up until the case unsnapped Figure 3 Opening the case 1 2 3 4...

Page 11: ...p of front case 2nd put the power cable wire holder in the rubber groove of rear case 3rd place the cover on the bottom in the position as shown in the following figure Then press the cover until it s...

Page 12: ...s not powered and slide the holder left to open the SIM card holder put the SIM card on the holder as shown below with the gold colored contact area facing down taking care to align the cut mark slide...

Page 13: ...e device is designed to be installed in vehicles that operate on 12V 24V vehicle without the need for external transformers Figure 6 Typical Power Connection Note 1 Do not connect any external cable o...

Page 14: ...2s Off GNSS not fixed Three flashing 100ms On 500ms off 100ms On 500ms Off 100ms On 2s off PDP not activated and GNSS not fixed One flashing Three flashing 100ms On 2s off 100ms On 500ms off 100ms On...

Page 15: ...Sensor Direction GB100MG Lite has an internal 3 axis accelerometer supporting driving behavior monitoring and motion detection The following shows the direction of the motion sensor The Z axis faces...

Page 16: ...for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment...