• 100KΩ potentiometer signal readouts, and
managing outputs
accordingly
• controlled by momentary or toggle switches
The RGBW Controller may control:
• 12 / 24VDC powered RGB strips
• 12 / 24VDC powered RGBW strips
• 12 / 24VDC powered LED strips, bulbs, etc.
• 12 / 24VDC powered halogen lights
Additional features:
• 100KΩ sensors signal readouts
• 100KΩ potentiometer signal readouts, and
managing outputs
accordingly
• controlled by momentary or toggle switches
Item
Description
Power Supply
12 / 24V DC
PWM output
frequency
488Hz
Rated output power
8A for single output channel,13A at
max.(3,25A for R.G.B.W. single
output channel is suggested)
Max load (e.g.
halogen bulbs)
At 12V- 156W combined
At 24V- 312W combined
LED Indicator
Red/Green *1
Operation
temperature
0
℃
~40
℃
Distance
up to 30 m indoors
Dimensions
(W x H x D)
40.5 mm x 32 mm x 14.5 mm
Package
dimensions
(W x H x D)
79 mm x 52 mm x 22 mm
Weight
28 g
Gross weight
(packaging included)
34 g
Electricity
consumption
12V: 0.48W; 24V: 0.72W
For installation in
boxes
Ø ≥ 60 mm or 2M
*Specification is subject to change without prior notice.
Multilevel Switch Device Information
GENERIC_TYPE_SWITCH_MULTILEVEL
SPECIFIC_TYPE_POWER_SWITCH_MULTILEVEL
Multilevel Switch Command Class
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_DEVICE_RESE
T_LOCALLY,
COMMAND_CLASS_POWERLEVEL
_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V2
COMMAND_CLASS_SWITCH_COLOR_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
Detailed description of each command class
ZWAVEPLUS INFO command class
The Z-Wave Plus Info Get Command is used to
get additional information of the Z-Wave Plus
device in question.
BASIC command class
The module will be turned ON or OFF after
receiving the BASIC_SET
command.
To be turned on:
[Command Class Basic , Basic Set, Basic
Value = 0x01~0x63 in percentage; FF set
to last value]
To be closed:
[Command Class Basic , Basic Set, Basic Value
= 0x00]
SWITCH MULTILEVEL command class
The module will be turned ON or OFF after
receiving the SWITCH_ MULTILEVEL_SET
command.
To be turned on:
[Command Class Multilevel , Multilevel Set,
Basic Value = 0x01~0x63 in percentage; FF set
to last value]
To be closed:
[Command Class Multilevel , Multilevel Set,
Basic Value = 0x00]
SWITCH COLOR command class
This class is used for Color setting.
See the following table for configuration
variables
:
DEVICE RESET LOCALLY command class
The Device Reset Locally Command Class is
used to notify central controllers that a Z-Wave
device is resetting its network specific
parameters.
VERSION command class
The user can enquire the version of the unit
using VERSION_GET
command. It will return
VERSION_REPORT Command.
Version Report Command:
[Command Class Version, Version Report, Z-
Wave Library Type, Z-Wave
Protocol Version, Z-Wave Protocol Sub
Version, Application Version, Application Sub
Version]
MANUFACTURER SPECIFIC command class
The user can use the Manufacturer Specific
Get Command to request manufacturer
specific information from another node.
CE Caution
Electromagnetic compatibility and Radio
spectrum Matters (ERM); Short Range Devices
(SRD); Radio equipment to be used in the 25
MHz to 1,000 MHz frequency range with power
levels ranging up to 500 mW; Part 2:
Harmonized EN covering essential
requirements under article 3.2 of the R&TTE
Directive.
WEEE Information
For EU (European Union) member users:
According to the
WEEE (Waste electrical and electronic
equipment) Directive, do not dispose of this
product as household waste or commercial
waste. Waste electrical and electronic
equipment should be appropriately collected and
recycled as required by practices
established for your country.
For information on recycling of this product,
please contact your local authorities, your
household waste disposal service or the shop
where you purchased the product.
Z-Wave Plus
This product can be included and operated in any
Z-Wave network with other Z-Wave certified
devices from other manufacturers and/or other
applications. All non-battery operated nodes within
the network will act as repeaters regardless of
vendor to increase reliability of the network
Goap d.o.o. Nova Gorica
Ulica Klementa Juga 007
5250 Solkan
Slovenia
E-mail:
Tel: +386 5 335 95 00
Web:
www.qubino.com
Date: 6.1.2017
Document: Qubino_Flush RGBW Dimmer PLUS
user manual_V1.1_eng
Capability ID
Color
State Level
0 (0x00)
White
0x00-0xFF
2 (0x02)
Red
0x00-0xFF
3 (0x03)
Green
0x00-0xFF
4 (0x04)
Blue
0x00-0xFF
Regulatory Compliance