zero each time the module receive ON command
regardless from where it comes (push button,
associated module, controller,..).
Available configuration parameters (data type is 2
Byte DEC):
default value 0
0 - Auto OFF disabled
1 - 32535 = 1second (0,01s)
– 32535 seconds
(325,35s) Auto OFF enabled with define time,
step is 1s or 10ms according to parameter
nr.15
Parameter no. 12 - Automatic turning on output
after set time
When relay is OFF it goes automatically ON after
time defined by this parameter. Timer is reset to
zero each time the module receive OFF command
regardless from where it comes (push button,
associated
module,
controller,..).
Available
configuration parameters (data type is 2 Byte
DEC):
default value 0
0 - Auto ON disabled
1 - 32535 = 1second (0,01s) - 32536 seconds
(325,35s) Auto ON enabled with define time,
step is 1s or 10ms according to parameter
nr.15
Parameter no. 15 - Automatic turning off / on
seconds or milliseconds selection
Available configuration parameters (data type is 1
Byte DEC):
default value 0
0 - seconds selected
1 - milliseconds selected
NOTE: This parameter is valid for both, turning on
and turning off parameters.
Parameter no. 30 - Saving the state of the relay
after a power failure
Available configuration parameters (data type is 1
Byte DEC):
default value 0
0 - Flush 1D relay module saves its state
before power failure (it returns to the last
position saved before a power failure)
1 - Flush 1D relay module does not save
the state after a power failure, it returns to
"off" position.
Parameter no. 63
– Output Switch selection
Set value means the type of the device that is
connected to the output. The device type can be
normally open (NO) or normally close (NC).
Available configuration parameters (data type is 1
Byte DEC):
default value 0
0 - When system is turned off the output is 0V
(NC).
1 - When system is turned off the output is
230V or 24V (NO).
Parameter no. 100
– Disable Endpoint I2 or
select Notification Type and Event
Enabling I2 means that Endpoint (I2) will be
present on UI. Disabling it will result in hiding the
endpoint according to the parameter set value.
Additionally, a Notification Type and Event can be
selected for the endpoint. Available configuration
parameters (data type is 1 Byte DEC):
Endpoint device type selection:
- notification sensor (1 - 6):
GENERIC_TYPE_SENSOR_NOTIFICATION,
SPECIFIC_TYPE_NOTIFICATION_SENSOR
default value 1
1 - Home Security; Motion Detection,
unknown location
2 - Carbon Monoxide; Carbon Monoxide
detected, unknown location.
3 - Carbon Dioxide; Carbon Dioxide detected,
unknown location.
4 - Water Alarm; Water Leak detected,
unknown location.
5 - Heat Alarm; Overheat detected, unknown
location.
6 - Smoke Alarm; Smoke detected, unknown
location.
0 - Endpoint, I2 disabled
- sensor binary (9):
GENERIC_TYPE_SENSOR_BINARY,
SPECIFIC_TYPE_NOT_USED
9 - Sensor binary
NOTE 1: After parameter change, first exclude
module (without setting parameters to default
value) and then re include the module!
NOTE 2: When the parameter is set to value 9 the
notifications are send for Home Security
.
Parameter no. 110
– Temperature sensor offset
settings
Set value is added or subtracted to actual
measured value by sensor. Available config.
parameters (data type is 2 Byte DEC):
default value 32536
32536 - offset is 0.0C
From 1 to 100 -
value from 0.1 °C to 10.0 °C is
added to actual measured temperature.
From 1001 to 1100 - value from -
0.1 °C to
-
10.0 °C is subtracted to actual measured
temperature.
Parameter no. 120
– Digital temperature sensor
reporting
If digital temperature sensor is connected, module
reports measured temperature on temperature
change defined by this parameter.
Available configuration parameters (data type is 1
Byte DEC):
default value 5 =
0,5°C
0 - Reporting disabled
1-
127 = 0,1°C - 12,7°C, step is 0,1°C
Technical Specifications
Power supply
110 -
230 VAC ±10%
50/60Hz, 24-30VDC
Rated load current of AC
output (resistive load)*
1 X 10A / 230VAC
Rated load current of DC
output (resistive load)
1 X 10A / 30VDC
Output circuit power of
AC output (resistive
load)
2300W (230VAC)
Output circuit power of
DC output (resistive
load)
240W (24VDC)
Digital temperature
sensor range (sensor
must be ordered
separately)
-50 ~ +1
25°C
Operation temperature
-10 ~ +40
°C
Distance
up to 30 m indoors
(depending on
building materials)
Dimensions (WxHxD)
(package)
41,8x36,8x15,4mm
(79x52x22mm)
Weight (Brutto with
package)
28g (34g)
Electricity consumption 0,4W
For installation in boxes
Ø ≥ 60mm or 2M
Switching
Relay
* In case of load other than resistive, pay attention
to the value of cos φ and if necessary apply load
lower than the rated load. Max current for cos
φ=0,4 is 3A at 250VAC, 3A at 24VDC L/R=7ms.
Supported loads:
Electric motor
Convent. incandescent and halogen lights
LED and CFL bulb, low voltage halogen
bulbs with electronic transformer
Low voltage halogen bulbs with
conventional transformer
Z-Wave Device Class:
ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_AL
WAYS_ON
GENERIC_TYPE_SWITCH_BINARY
SPECIFIC_TYPE_POWER_SWITCH_BINARY
Z-Wave Supported Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_BASIC
COMMAND_CLASS_SENSOR_BINARY
COMMAND_CLASS_NOTIFICATION_V5
COMMAND_CLASS_SWITCH_ALL
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_MULTI_CHANNEL_V4
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_
V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_MARK
COMMAND_CLASS_BASIC
Endpoint 1
COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_BASIC
COMMAND_CLASS_SWITCH_ALL
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_
V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2
COMMAND_CLASS_MARK
COMMAND_CLASS_BASIC
Endpoint 2 (I2):
Device Class:
ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_AL
WAYS_ON
GENERIC_TYPE_SENSOR_NOTIFICATION
SPECIFIC_TYPE_NOTIFICATION_SENSOR
Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SENSOR_BINARY
COMMAND_CLASS_BASIC
COMMAND_CLASS_NOTIFICATION_V5
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_
V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2
COMMAND_CLASS_MARK
COMMAND_CLASS_BASIC
NOTE
:
The above list is valid for the product with a
temperature sensor connected to TS terminal. In
case the sensor isn
’t connected then following
command class isn’t supported:
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
This product can be included and operated in any
Z-Wave network with other Z-Wave certified
devices from any other manufacturers. All
constantly powered nodes in the same network will
act as repeaters regardless of the vendor in order
to increase reliability of the network.
Important disclaimer
Z-Wave wireless communication is inherently not
always 100% reliable, and as such, this product
should not be used in situations in which life and/or
valuables are solely dependent on its function.
Warning!
Do not dispose of electrical appliances as unsorted
municipal waste, use separate collection facilities.
Contact your local government for information
regarding the collection systems available. If
electrical appliances are disposed of in landfills or
dumps, hazardous substances can leak into the
groundwater and get into the food chain, damaging
your health and well-being. When replacing old
appliances with new once, the retailer is legally
obligated to take back your old appliance for
disposal at least for free of charge.
This user manual is subject to change and
improvement without notice.
NOTE: User manual is valid for module with SW
version S2 (SW version is part of P/N)!
Example: P/N: ZMNHNDx H1
S2
P1
Qubino
Goap d.o.o. Nova Gorica
Ulica Klementa Juga 007
5250 Solkan
Slovenia
E-mail:
info@qubino.com
Tel: +386 5 335 95 00
Web:
www.qubino.com
Date: 18.12.2015
Document: Qubino_Flush 1D relay
PLUS user
manual_V1.2_eng