background image

 

 

 

zero  each  time the module receive ON command 

regardless  from  where  it  comes  (push  button, 

associated module, controller,..).     

Available configuration parameters (data type is 2 

Byte DEC): 

 

default value 0 

 

0 - Auto OFF disabled   

 

1 - 32535 = 1second (0,01s) 

– 32535 seconds 

(325,35s) Auto OFF enabled with define time, 

step  is  1s  or  10ms  according  to  parameter 

nr.15 

Parameter no. 12 - Automatic turning on output 

after set time   

When relay is OFF it goes  automatically  ON after 

time  defined  by  this  parameter.  Timer  is  reset  to 

zero each time the module receive OFF command 

regardless  from  where  it  comes  (push  button, 

associated 

module, 

controller,..). 

Available 

configuration  parameters  (data  type  is  2  Byte 

DEC): 

 

default value 0 

 

0 - Auto ON disabled   

 

1 - 32535 = 1second (0,01s) - 32536 seconds 

(325,35s)  Auto  ON  enabled  with  define  time, 

step  is  1s  or  10ms  according  to  parameter 

nr.15 

Parameter  no.  15  -  Automatic  turning  off  /  on 

seconds or milliseconds selection 

Available configuration parameters (data type is 1 

Byte DEC): 

 

default value 0 

 

0 - seconds selected 

 

1 - milliseconds selected 

NOTE: This parameter is valid for both, turning on 

and turning off parameters. 

Parameter no. 30 - Saving the state of the relay 

after a power failure 

Available configuration parameters (data type is 1 

Byte DEC): 

 

default value 0 

 

0  -  Flush  1D  relay  module  saves  its  state 

before  power  failure  (it  returns  to  the  last 

position saved before a power failure) 

 

1 - Flush 1D relay module does not save   

the state after a power failure, it returns to     

"off" position. 

Parameter no. 63 

– Output Switch selection 

Set value means the type of the device that is 

connected to the output. The device type can be 

normally open (NO) or normally close (NC).   

Available configuration parameters (data type is 1 

Byte DEC): 

 

default value 0   

 

0 - When system is turned off the output is 0V 

(NC). 

 

1  -  When  system  is  turned  off  the  output  is 

230V or 24V (NO). 

Parameter no. 100 

– Disable Endpoint I2 or 

select Notification Type and Event

 

Enabling  I2  means  that  Endpoint  (I2)  will  be 

present  on  UI.  Disabling  it  will  result  in  hiding  the 

endpoint  according  to  the  parameter  set  value. 

Additionally, a Notification Type and Event can be 

selected  for  the  endpoint.  Available  configuration 

parameters (data type is 1 Byte DEC): 

Endpoint device type selection: 

-    notification sensor (1 - 6):

 

GENERIC_TYPE_SENSOR_NOTIFICATION, 

SPECIFIC_TYPE_NOTIFICATION_SENSOR 

 

default value 1 

 

1 - Home Security; Motion Detection, 

unknown location 

      2 - Carbon Monoxide; Carbon Monoxide 

detected, unknown location. 

 

3 - Carbon Dioxide; Carbon Dioxide detected, 

unknown location. 

 

4 - Water Alarm; Water Leak detected, 

unknown location. 

 

5 - Heat Alarm; Overheat detected, unknown 

location. 

 

6 - Smoke Alarm; Smoke detected, unknown 

location. 

 

0 - Endpoint, I2 disabled

 

-    sensor binary (9):

 

GENERIC_TYPE_SENSOR_BINARY, 

SPECIFIC_TYPE_NOT_USED 

 

9 - Sensor binary   

NOTE 1: After parameter change, first exclude 

module (without setting parameters to default 

value) and then re include the module! 

NOTE 2: When the parameter is set to value 9 the 

notifications are send for Home Security

.

 

Parameter no. 110 

– Temperature sensor offset 

settings 

Set  value  is  added  or  subtracted  to  actual 

measured  value  by  sensor.  Available  config. 

parameters (data type is 2 Byte DEC): 

 

default value 32536 

 

32536 - offset is 0.0C 

 

From 1 to 100 - 

value from 0.1 °C to 10.0 °C is 

added to actual measured temperature. 

 

From  1001  to  1100  -  value  from  -

0.1  °C  to 

-

10.0  °C  is  subtracted  to  actual  measured 

temperature. 

Parameter no. 120 

– Digital temperature sensor 

reporting 

If digital temperature sensor is connected, module 

reports  measured  temperature  on  temperature 

change defined by this parameter. 

Available  configuration  parameters  (data  type  is  1 

Byte DEC): 

 

default value 5 = 

0,5°C 

 

0 - Reporting disabled 

 

1- 

127 = 0,1°C - 12,7°C, step is 0,1°C 

 
Technical Specifications     

 

Power supply 

110 - 

230 VAC ±10% 

50/60Hz, 24-30VDC 

Rated load current of AC 

output (resistive load)* 

1 X 10A / 230VAC 

Rated load current of DC 

output (resistive load) 

1 X 10A / 30VDC 

Output circuit power of 

AC output (resistive 

load) 

2300W (230VAC) 

Output circuit power of 

DC output (resistive 

load) 

240W (24VDC) 

Digital temperature 

sensor range (sensor 

must be ordered 

separately)

 

-50 ~ +1

25°C 

Operation temperature 

-10 ~ +40

°C 

Distance 

up to 30 m indoors 

(depending on 

building materials) 

Dimensions (WxHxD) 

(package) 

41,8x36,8x15,4mm 

(79x52x22mm) 

Weight (Brutto with 

package) 

28g (34g) 

Electricity consumption  0,4W 

For installation in boxes 

Ø ≥ 60mm or 2M 

Switching

 

Relay 

* In case of load other than resistive, pay attention 
to the value of cos φ and if necessary apply load 
lower than the rated load. Max current for cos 
φ=0,4 is 3A at 250VAC, 3A at 24VDC L/R=7ms. 

 

Supported loads: 

 

 

Electric motor 

 

 

Convent. incandescent and halogen lights 

 

 

LED and CFL bulb, low voltage halogen 

  bulbs with electronic transformer

 

 

 

Low voltage halogen bulbs with     

  conventional transformer 

 

 

Z-Wave Device Class:   

ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_AL

WAYS_ON 

GENERIC_TYPE_SWITCH_BINARY 

SPECIFIC_TYPE_POWER_SWITCH_BINARY 

Z-Wave Supported Command Classes:   

COMMAND_CLASS_ZWAVEPLUS_INFO 

COMMAND_CLASS_VERSION_V2 

COMMAND_CLASS_MANUFACTURER_SPECIFIC 

COMMAND_CLASS_DEVICE_RESET_LOCALLY 

COMMAND_CLASS_POWERLEVEL 

COMMAND_CLASS_BASIC 

COMMAND_CLASS_SENSOR_BINARY 

COMMAND_CLASS_NOTIFICATION_V5 

COMMAND_CLASS_SWITCH_ALL 

COMMAND_CLASS_SWITCH_BINARY 

COMMAND_CLASS_SENSOR_MULTILEVEL_V7 

COMMAND_CLASS_MULTI_CHANNEL_V4 

COMMAND_CLASS_ASSOCIATION_V2 

COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_

V3 

COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 

COMMAND_CLASS_CONFIGURATION 

COMMAND_CLASS_MARK 

COMMAND_CLASS_BASIC 

Endpoint 1 

COMMAND_CLASS_ZWAVEPLUS_INFO 

COMMAND_CLASS_VERSION_V2 

COMMAND_CLASS_BASIC 

COMMAND_CLASS_SWITCH_ALL 

COMMAND_CLASS_SWITCH_BINARY 

COMMAND_CLASS_SENSOR_MULTILEVEL_V7 

COMMAND_CLASS_ASSOCIATION_V2 

COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_

V3 

COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 

COMMAND_CLASS_MARK 

COMMAND_CLASS_BASIC 

Endpoint 2 (I2): 

Device Class: 

ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_AL

WAYS_ON 

GENERIC_TYPE_SENSOR_NOTIFICATION 

SPECIFIC_TYPE_NOTIFICATION_SENSOR 

Command Classes: 

COMMAND_CLASS_ZWAVEPLUS_INFO 

COMMAND_CLASS_VERSION_V2 

COMMAND_CLASS_SENSOR_BINARY 

COMMAND_CLASS_BASIC 

COMMAND_CLASS_NOTIFICATION_V5 

COMMAND_CLASS_ASSOCIATION_V2 

COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_

V3 

COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 

COMMAND_CLASS_MARK 

COMMAND_CLASS_BASIC 

NOTE

:

 The above list is valid for the product with a 

temperature sensor connected to TS terminal. In 

case the sensor isn

’t connected then following 

command class isn’t supported: 

COMMAND_CLASS_SENSOR_MULTILEVEL_V7 

This product can be included and operated in any 

Z-Wave network with other Z-Wave certified 

devices from any other manufacturers. All 

constantly powered nodes in the same network will 

act as repeaters regardless of the vendor in order 

to increase reliability of the network. 

 

Important disclaimer

 

Z-Wave  wireless  communication  is  inherently  not 

always  100%  reliable,  and  as  such,  this  product 

should not be used in situations in which life and/or 

valuables are solely dependent on its function.

 

 
Warning! 

Do not dispose of electrical appliances as unsorted 

municipal waste, use separate collection facilities.   

Contact  your  local  government  for  information 

regarding  the  collection  systems  available.  If 

electrical appliances are disposed of in landfills or 

dumps,  hazardous  substances  can  leak  into  the 

groundwater and get into the food chain, damaging 

your  health  and  well-being.  When  replacing  old 

appliances  with  new  once,  the  retailer  is  legally 

obligated  to  take  back  your  old  appliance  for 

disposal at least for free of charge. 

 

This user manual is subject to change and 

improvement without notice.

 

 

NOTE: User manual is valid for module with SW 

version S2 (SW version is part of P/N)! 

Example: P/N: ZMNHNDx H1

S2

P1 

 

 

 

 

 

 

 

 

 

Qubino

   

Goap d.o.o. Nova Gorica 

Ulica Klementa Juga 007 

5250 Solkan 

Slovenia 

 

E-mail:  

[email protected]

   

Tel:       +386 5 335 95 00 

Web:     

www.qubino.com

     

 

Date: 18.12.2015 

Document: Qubino_Flush 1D relay 

PLUS user

 

manual_V1.2_eng                                                                   

Reviews: