ORDERING CODE 

Z-WAVE FREQUENCY 

ZMNHND1 

868,4 MHz 

ZMNHND2

 

921,4 MHz 

ZMNHND3

 

908,4 MHz 

ZMNHND4

 

869,0 MHz 

ZMNHND5

 

916,0 MHz 

 

This Z-Wave module is used for switching on or off 

the electrical device (e.g. light or fan). The module 

can be controlled either through Z-wave network or 

through the wall switch.

 

The  module  is  designed  to  be  mounted  inside  a 
“flush  mounting  box”,  hidden  behind  a  traditional 
wall switch. 

Module supports connection of digital temperature 

sensor. It is designed to act as repeater in order to 

improve range and stability of Z-wave network.

                                         

 

 

Supported switches 

Module  supports 

mono-stable

  switches  (push 

button)  and 

bi-stable

  switches.  The  module  is 

factory set to operate with bi-stable switches.   

 

Installation   

 

Before  the  installation  disconnect  power 

supply. 

 

Connect  the  module  according  to  electrical 

diagram.   

 

Locate  the  antenna  far  from  metal  elements 

(as far as possible).   

 

Do not shorten the antenna. 

 
Danger of electrocution!   

 

Module installation requires a great degree of 

skill and may be performed only by a qualified 

and licensed electrician. 

 

Even  when  the  module  is  turned  off,  voltage 

may be present on its terminals. Any work on 

configuration  changes  related  to  connection 

mode  or  load  must  be  always  performed  by 

disconnected power supply (disable the fuse). 

 
Note! 

Do  not  connect  the  module  to  loads  exceeding 

recommended values. Connect the module only in 

accordance  to  the  below  diagrams.  Improper 

connections may be dangerous.

   

Electrical  installation  must  be  protected  by  over 

current  protection  fuse  10A,  Tag  lag  T,  rated 

breaking capacity 1500V (ESKA 522.7..) according 

to wiring diagram. 

 
Package contents 

 

Flush 1D relay 

 

 

Electrical diagram 230VAC 

 

 

 

 

 

 

 

 

 

 

 
 

 

Option for different load power supply - DPLS: 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes for the diagrams: 

Electrical diagram 24VDC 
 
   
 

 
 

 
 
 
 
 

 

 

Option for different load power supply - DPLS: 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes for the diagrams: 

 

NOTE! 

 

Output contact is voltage free (dry contact), so also 

loads  with  different  power  supply  can  be 

connected to the module.

 

 
 

 

 

 

 
NOTE:  Service  button  S  can’t  be  used  when 
module is connected to 110-230V power supply. 

Durability of the module depends on applied load. 

For  resistive  load  (light  bulbs,  etc.)  and  10A 

current  consumption  of  each  individual  electrical 

device, the durability exceeds 100.000 switches of 

each individual electrical device.   

 

Module  Inclusion  (Adding  to  Z-wave 
network) 

 

Connect module to power supply (with   

temperature 

sensor 

connected 

if 

purchased), 

 

auto-inclusion  (works  for  about  5  seconds 

after connected to power supply) or 

 

press service button 

S

 for more than 2 second 

or 

 

press  push  button  I1  three times  within 3s  (3 

times change switch state within 3 seconds). 

NOTE1: For auto-inclusion procedure, first set 

main 

controller

  into  inclusion  mode  and  then  connect 

module to power supply. 

NOTE2:  When  connecting  temperature  sensor  to 

module  that has  already  been included,  you have 

to  exclude  module  first.  Switch  off  power  supply, 

connect the sensor and re-include the module. 

 

Module Exclusion/Reset (Removing from 
Z-Wave network) 

 

Connect module to power supply   

 

bring module within maximum 1 meter (3 feet) 

of the main controller, 

 

enable add/remove mode on main controller 

 

press service button 

S

 for more than 6 second 

or 

 

press push button I1

 

five times within 3s (5   

 

times change switch state within 3 seconds) in 

the  first  60  seconds  after  the  module  is 

connected to the power supply. 

By  this  function  all  parameters  of  the  module  are 

set to default values and own ID is deleted 

If service button S is pressed more than 2 and less 

than  6  seconds  (or  if  push  button  I1  is  pressed 

three  times  within  3s)  module  is  excluded,  but 

configuration  parameters  are  not  set  to  default 

values

.

   

 
Associations 

Associations  enables  Flush  1D  relay  module  to 

transfer commands inside Z-Wave network directly 

(without main controller) to other Z-Wave modules. 

Associated Groups:

   

Root device: 

Group 

1: 

Lifeline 

group 

(reserved 

for 

communication  with  the  main  controller),  1  node 

allowed. 

Group  2:  basic  on/off  (triggered  at  change  of  the 

output  state  and  reflecting  its  state)  up  to  16 

nodes. 

Group  3:  basic  on/off  (triggered  at  change  of  the 

input  I2  state  and  reflecting  its  state)  up  to  16 

nodes. 

Group  4:  Binary  Sensor  Report  (triggered  at 

change of the input I2 state and reflecting its state) 

up to 16 nodes.   

Group  5:  Notification  Report  (triggered  at  change 

of  the  input  I2  state  and  reflecting  its  state)  up  to 

16 nodes. 

Endpoint 1:

 

Group 1: Lifeline group, 0 nodes allowed. 

Group  2:  basic  on/off  (triggered  at  change  of  the 

output  state  and  reflecting  its  state)  up  to  16 

nodes. 

Endpoint 2:

 

Group 1: Lifeline group, 0 nodes allowed. 

Group  2:  basic  on/off  (triggered  at  change  of  the 

input  I2  state  and  reflecting  its  state)  up  to  16 

nodes. 

Group  3:  Binary  Sensor  Report  (triggered  at 

change of the input I2 state and reflecting its state) 

up to 16 nodes.   

Group  4:  Notification  Report  (triggered  at  change 

of  the  input  I2  state  and  reflecting  its  state)  up  to 

16 nodes.   

 

Configuration parameters 

Parameter no. 1 

– Input 1 switch type 

Available configuration parameters (data type is 1 

Byte DEC): 

 

default value 1 

 

0 - mono-stable switch type (push button) 

 

1 - bi-stable switch type   

Parameter no. 2 

– Input 2 contact type 

Available configuration parameters (data type is 1 

Byte DEC): 

 

default value 0 

 

0 - NO (normally open) input type 

 

1 - NC (normally close) input type 

Parameter  no.  10  -  Activate  /  deactivate 

functions ALL ON/ALL OFF

 

Available configuration parameters (data type is 2 

Byte DEC): 

 

default value 255 

 

255 - ALL ON active, ALL OFF active 

 

0 - ALL ON is not active ALL OFF is not active 

 

1 - ALL ON is not active ALL OFF active 

 

2 - ALL ON active ALL OFF is not active 

Flush  1D  relay  module  responds  to  commands 

ALL ON / ALL OFF  that may be sent  by the  main 

controller  or  by  other  controller  belonging  to  the 

system.   

Parameter no. 11 - Automatic turning off output 

after set time   

When relay is ON it goes  automatically  OFF after 

time  defined  by  this  parameter.  Timer  is  reset  to 

Neutral lead 

Live lead

 

Input for electrical device power supply

 

Output for electrical device

 

I2 

Input for switch /push button or sensor

 

I1 

Input for switch /push button 

 

TS 

Terminal  for  digital  temperature  sensor 

(only  for  Flush  1D  relay  module 

compatible  digital  temperature  sensor, 

which must be ordered separately).

 

+ VDC

 

- VDC

 

Input for electrical device power supply

 

Output for electrical device

 

I2 

Input for switch /push button or sensor

 

I1 

Input for switch /push button 

 

TS 

Terminal  for  digital  temperature  sensor 

(only  for  Flush  1D  relay  module 

compatible  digital  temperature  sensor, 

which must be ordered separately).

 

Service button (used to 

add or remove module 

from the Z-Wave 

network). 