Parameter no. 65 

– Dimming time (soft on/off) 

Set value means time of  moving the Dimmer  between  min. 
and  max.  dimming values by short  press of push  button I1 
or  controlled  through  UI  (BasicSet). Available  configuration 
parameters (data type is 2 Byte DEC): 

 

default value 100 = 1s 

 

50  -  255  =  500  mseconds  -  2550  mseconds  (2,55s), 
step is 10 mseconds 

Parameter no. 66 

– Dimming time when key pressed

 

Time  of  moving  the  Dimmer  between  min.  and  max 
dimming  values  by  continues  hold  of  push  button  I1  or 
associated device. Available configuration parameters (data 
type is 2 Byte DEC): 

 

default value 3 = 3s 

 

1- 255 = 1 second 

– 255 seconds 

Parameter no. 67 

– Ignore start level 

This parameter is used with association group 3. 
A  receiving  device  SHOULD  respect  the  start  level  if  the 
Ignore Start Level bit is 0. A receiving  device MUST ignore 
the  start  level  if  the  Ignore  Start  Level  bit  is  1.  Available 
configuration parameters (data type is 1 Byte DEC): 

 

default value 0  

 

0 - respect start level 

 

1 - ignore start level 

Parameter no. 68 

– Dimming duration

 

This parameter is used with association group 3. 
The Duration field MUST specify the time that the transition 
should take from the current value to the new target value. 
A  supporting  device  SHOULD  respect  the  specified 
Duration  value.  Available  configuration  parameters  (data 
type is 1 Byte DEC): 

 

default  value  0  (dimming  duration  according  to 
parameter 66) 

 

1 - 127 (from 1 to 127 seconds) 

Parameter no. 100 

– Enable / Disable Endpoints I2 or 

select Notification Type and Event

 

Enabling I2  means that Endpoint (I2) will  be present on UI. 
Disabling it will result in hiding the endpoint according to the 
parameter  set  value.  Additionally,  a  Notification  Type  and 
Event  can  be  selected  for  the  endpoint.  Available 
configuration parameters (data type is 1 Byte DEC): 

Endpoint device type selection: 
-  notification sensor (1 - 6): 

GENERIC_TYPE_SENSOR_NOTIFICATION, 
SPECIFIC_TYPE_NOTIFICATION_SENSOR 

 

default value 0 

 

1 - Home Security; Motion Detection, unknown loc. 

 

2 - CO; Carbon Monoxide detected, unknown  loc. 

 

3 - CO2; Carbon Dioxide detected, unknown loc. 

 

4 - Water Alarm; Water Leak detected, unknown loc. 

 

5 - Heat Alarm; Overheat detected, unknown loc. 

 

6 - Smoke Alarm; Smoke detected, unknown loc. 

 

0 - Endpoint, I2 disabled

 

-  sensor binary (9):

 GENERIC_TYPE_SENSOR_BINARY, 

SPECIFIC_TYPE_NOT_USED 

 

9 - Sensor binary  

NOTE1: After parameter change, first exclude module 
(without setting parameters to default value) then wait at 
least 30s and then re include the module! 
NOTE 2: W hen the parameter is set to value 9 the 
notifications are send for Home Security. 

Parameter no. 101 

– Enable / Disable Endpoints I3 or 

select Notification Type and Event

 

Enabling I3  means that Endpoint (I3) will  be present  on UI. 
Disabling it will result in hiding the endpoint according to the 
parameter  set  value.  Additionally,  a  Notification  Type  and 
Event  can  be  selected  for  the  endpoint.  Available 
configuration parameters (data type is 1 Byte DEC): 

Endpoint device type selection: 

- notification sensor (1 - 6):

 

GENERIC_TYPE_SENSOR_NOTIFICATION, 
SPECIFIC_TYPE_NOTIFICATION_SENSOR 

 

default value 0 

 

1 - Home Security; Motion Detection, unknown loc. 

 

2 - CO; Carbon Monoxide detected, unknown  loc.. 

 

3 - CO2; Carbon Dioxide detected, unknown loc. 

 

4 - Water Alarm; Water Leak detected, unknown loc. 

 

5 - Heat Alarm; Overheat detected, unknown loc. 

 

6 - Smoke Alarm; Smoke detected, unknown loc. 

 

0 - Endpoint, I3 disabled

 

- sensor binary (9):

 GENERIC_TYPE_SENSOR_BINARY, 

SPECIFIC_TYPE_NOT_USED 

 

9 - Sensor binary  

NOTE1: After parameter change, first exclude module 
(without setting parameters to default value) then wait at 
least 30s and then re include the module! 
NOTE 2: W hen the parameter is set to value 9 the 
notifications are send for Home Security. 

Parameter no. 110 

– Temperature sensor offset settings 

Set value is added or  subtracted to actual  measured value 
by sensor.  Available configuration parameters (data type is 
2 Byte DEC): 

 

default value 32536 

 

32536 - offset is 0.0C 

 

From 1 to 100 - value from 0.1 °C to 10.0 °C is added 
to actual measured temperature.  

 

From 1001 to 1100  - value from -0.1 °C to -10.0 °C is 
subtracted to actual measured temperature. 

Parameter no. 120 

–Temperature sensor reporting 

If  digital  temperature  sensor  is  connected,  module  reports 
measured  temperature  on  temperature  change  defined  by 
this  parameter.  Available  configuration  parameters  (data 
type is 1 Byte DEC): 

 

default value 5 = 0,5°C change 

 

0 - reporting disabled 

 

1 - 127 = 0,1°C - 12,7°C, step is 0,1°C 

Parameter No. 250 

– Unsecure / Secure Inclusion 

Available configuration parameter (data type is 1 Byte Dec): 

 

default Value 0 

 

 Unsecure Inclusion 

 

 Secure Inclusion 

A  Flush  dimmer  supports  both,  the  secure  and  unsecure 
inclusion.  Even  if  the  controller  does  not  support  security 
command  classes,  a  dimmer  could  be  included  as 
unsecure and keep all the functionality. 

Technical Specifications    

Power supply 

110 - 230 VAC ±10% 

50 or 60Hz**,(24-30VDC) 

Rated load current of AC 

output  

0,6A / 230VAC 

Rated load current of DC 

output 

0,85A / 30VDC 

Output circuit power of AC 

output (resistive load)* 

140W (230VAC) 

Output circuit power of DC 

output (resistive load) 

21W (24VDC) 

Power measurement accuracy  +/-2W 

Digital temperature sensor 

range (sensor must be 

ordered separately) 

-50 ~ +125°C 

Operation temperature 

-10 ~ +40°C 

Distance 

up to 30 m indoors 

(depending on building 

materials) 

Dimensions (WxHxD) 

41,8x36,8x15,4mm 

(package) 

(79x52x22mm) 

Weight (Brutto with package) 

28g (34g) 

Electricity consumption 

0,7W 

For installation in boxes 

Ø ≥ 60mm or 2M, 

depth≥ 60mm 

Switching 

MOSFET (Trailing edge) 

*max  100W   mono-phase  asynchronous  fan  motor  can  be 
connected to Dimmer output.

 

** depend on ordering code 
Max Power Limit is automatically set by a software. If  max 
power  is  exceeded  for  more  than  5  seconds,  the  output  is 
turned  off  up  to  the  next  power  cycle  of  the  module.When 
overload  occurred,  Event  “Over-load  detected”  is  send  to 
the gateway. 
Consumption  in  kWh  is  reported  on  every  change  for 
0.1kWh. 

Description of switch function:  

Switch  toggles  (parameter  1 set  to  1)  the state  of  the  light 
bulb between the last dimming value and 0. If last dimming 
value  is  0  then  the  light  is  turned  100%  when  switch 
changes its state.  

Bulb types which support dimming function:  

 

The classical incandescent bulbs.  

 

Halogen bulbs operated by 230 V AC (High Voltage 
Halogen).  

 

Low voltage halogen bulbs with electronic or 
conventional transformer.  

 

Dimmable compact fluorescent bulb (CFL). If the bulb 
at low intensities flushes, it is recommended to set 
parameter 60 (minimum dimming value) to 30 or 
more.  

 

Dimmable LED bulbs.

 

Wave Device Class:  

ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_0N 

GENERIC_TYPE_SWITCH_MULTILEVEL 

SPECIFIC_TYPE_POWER_SWITCH_MULTILEVEL 

Z-Wave Supported Command Classes:  

COMMAND_CLASS_ZWAVEPLUS_INFO_V2, 

COMMAND_CLASS_VERSION_V2 

COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 

COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 

COMMAND_CLASS_POWERLEVEL_V1 

COMMAND_CLASS_SECURITY 

Securely Supported Command Classes: 

COMMAND_CLASS_BASIC_V1 

COMMAND_CLASS_SWITCH_ALL_V1 

COMMAND_CLASS_SWITCH_BINARY_V1 

COMMAND_CLASS_SENSOR_BINARY_V1 

COMMAND_CLASS_SWITCH_MULTILEVEL_V3 

COMMAND_CLASS_METER_V4 

COMMAND_CLASS_SENSOR_MULTILEVEl_V7 

COMMAND_CLASS_NOTIFICATION_V5 

COMMAND_CLASS_MULTI_CHANNEL_V4 

COMMAND_CLASS_ASSOCIATION_2 

COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 

COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 

COMMAND_CLASS_CONFIGURATION_V1 

COMMAND_CLASS_MARK 

COMMAND_CLASS_BASIC_V1 

COMMAND_CLASS_SWITCH_MULTILEVEL_V3 

Endpoint 1   

Device Class: 

ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_0N 

GENERIC_TYPE_SWITCH_MULTILEVEL 

SPE SPECIFIC_TYPE_POWER_SWITCH_MULTILEVEL 

Command Classes: 

COMMAND_CLASS_ZWAVEPLUS_INFO_V2 

COMMAND_CLASS_SECURITY 

COMMAND_CLASS_ASSOCIATION_2 

COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 

COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 

COMMAND_CLASS_BASIC_V1 

COMMAND_CLASS_SWITCH_ALL_V1 

COMMAND_CLASS_SWITCH_BINARY_V1 

COMMAND_CLASS_SWITCH_MULTILEVEL_V3 

COMMAND_CLASS_METER_V4 

COMMAND_CLASS_NOTIFICATION_V5 

COMMAND_CLASS_MARK 

COMMAND_CLASS_BASIC_V1 

Endpoint 2 (I2): 

Device Class: 

ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_0N 

GENERIC_TYPE_SENSOR_NOTIFICATION 

SPECIFIC_TYPE_NOTIFICATION_SENSOR 

Securely Supported Command Classes: 

COMMAND_CLASS_ZWAVEPLUS_INFO_V2 

COMMAND_CLASS_SECURITY 

COMMAND_CLASS_ASSOCIATION_V2 

COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 

COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 

COMMAND_CLASS_SENSOR_BINARY_V1 

COMMAND_CLASS_BASIC_V1 

COMMAND_CLASS_NOTIFICATION_V5 

COMMAND_CLASS_MARK 

COMMAND_CLASS_BASIC_V1 

Endpoint 3 (I3): 

Device Class: 

ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_0N 

GENERIC_TYPE_SENSOR_NOTIFICATION 

SPECIFIC_TYPE_NOTIFICATION_SENSOR 

Command Classes: 

COMMAND_CLASS_ZWAVEPLUS_INFO_V2 

COMMAND_CLASS_SECURITY 

COMMAND_CLASS_ASSOCIATION_V2 

COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 

COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 

COMMAND_CLASS_SENSOR_BINARY_V1 

COMMAND_CLASS_BASIC_V1 

COMMAND_CLASS_NOTIFICATION_V5 

COMMAND_CLASS_MARK 

COMMAND_CLASS_BASIC_V1 

Endpoint 4: 

Device Class: 

ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_0N 

GENERIC_TYPE_SENSOR_MULTILEVEL 

SPECIFIC_TYPE_ROUTING_SENSOR_MULTILEVEL 

Command Classes: 

COMMAND_CLASS_ZWAVEPLUS_INFO_V2 

COMMAND_CLASS_SECURITY 

COMMAND_CLASS_ASSOCIATION_V2 

COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 

COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 

COMMAND_CLASS_SENSOR_MULTILEVEL_V7 

NOTE

:

 The above list is valid for the product with a 

temperature sensor connected to TS terminal. In case the 
sensor is not connected then following command class isn’t 
supported: 

COMMAND_CLASS_SENSOR_MULTILEVEL_V7  

NOTE: The product supports the following  

COMMAND_CLASS_NOTIFICATION_V5

 events: 

-  Smoke Alarm v2 

– Smoke detected, unknown loc. (0x02) 

-  CO Alarm v2 

– CO detected, unknown location (0x02) 

-  CO2 Alarm 

– CO2 detected, unknown loc (0x02) 

-  Heat Alarm v2 

– Overheat detected, unknown location 

(0x02) 

-  Water Alarm v2 

– Water Leak detected, unknown 

location (0x02) 

-  Home Security 

– Motion Detection, unknown location 

(0x08) 

This product can be included and operated in any Z-Wave 
network with other Z-Wave certified devices from any other 
manufacturers. All constantly powered nodes in the same 
network will act as repeaters regardless of the vendor in 
order to increase reliability of the network.

 

Important disclaimer

 

Z-Wave wireless communication is inherently not always 
100% reliable, and as such, this product should not be used 
in situations in which life and/or valuables are solely 
dependent on its function. 

Warning! 

Do  not  dispose  of  electrical  appliances  as  unsorted 
municipal waste, use separate collection facilities.  
Contact your local government for information regarding the 
collection  systems  available.  If  electrical  appliances  are 
disposed  of  in  landfills  or  dumps,  hazardous  substances 
can  leak  into  the  groundwater  and  get  into  the  food  chain, 
damaging  your  health  and  well-being.  When  replacing  old 
appliances with new once, the retailer is legally obligated to 
take back your old appliance for disposal at least for free of 
charge. 
This user manual is subject to change and improvement 
without notice. 

NOTE

: User manual is valid for module with SW version S3 

(SW version is part of P/N)! Example: P/N: ZMNHDDx 
Hx

S3

Px 

Qubino

 

 

Goap d.o.o. Nova Gorica 

Ulica Klementa Juga 007 

5250 Solkan 

Slovenia 

E-mail:  

[email protected]

  

Tel:       +386 5 335 95 00 

Web:     

www.qubino.com

  

Date: 22.07.2016 

Document: Qubino_Flush Dimmer 

PLUS user manual_V1.6_eng

 

Reviews: