Parameter no. 65
– Dimming time (soft on/off)
Set value means time of moving the Dimmer between min.
and max. dimming values by short press of push button I1
or controlled through UI (BasicSet). Available configuration
parameters (data type is 2 Byte DEC):
default value 100 = 1s
50 - 255 = 500 mseconds - 2550 mseconds (2,55s),
step is 10 mseconds
Parameter no. 66
– Dimming time when key pressed
Time of moving the Dimmer between min. and max
dimming values by continues hold of push button I1 or
associated device. Available configuration parameters (data
type is 2 Byte DEC):
default value 3 = 3s
1- 255 = 1 second
– 255 seconds
Parameter no. 67
– Ignore start level
This parameter is used with association group 3.
A receiving device SHOULD respect the start level if the
Ignore Start Level bit is 0. A receiving device MUST ignore
the start level if the Ignore Start Level bit is 1. Available
configuration parameters (data type is 1 Byte DEC):
default value 0
0 - respect start level
1 - ignore start level
Parameter no. 68
– Dimming duration
This parameter is used with association group 3.
The Duration field MUST specify the time that the transition
should take from the current value to the new target value.
A supporting device SHOULD respect the specified
Duration value. Available configuration parameters (data
type is 1 Byte DEC):
default value 0 (dimming duration according to
parameter 66)
1 - 127 (from 1 to 127 seconds)
Parameter no. 100
– Enable / Disable Endpoints I2 or
select Notification Type and Event
Enabling I2 means that Endpoint (I2) will be present on UI.
Disabling it will result in hiding the endpoint according to the
parameter set value. Additionally, a Notification Type and
Event can be selected for the endpoint. Available
configuration parameters (data type is 1 Byte DEC):
Endpoint device type selection:
- notification sensor (1 - 6):
GENERIC_TYPE_SENSOR_NOTIFICATION,
SPECIFIC_TYPE_NOTIFICATION_SENSOR
default value 0
1 - Home Security; Motion Detection, unknown loc.
2 - CO; Carbon Monoxide detected, unknown loc.
3 - CO2; Carbon Dioxide detected, unknown loc.
4 - Water Alarm; Water Leak detected, unknown loc.
5 - Heat Alarm; Overheat detected, unknown loc.
6 - Smoke Alarm; Smoke detected, unknown loc.
0 - Endpoint, I2 disabled
- sensor binary (9):
GENERIC_TYPE_SENSOR_BINARY,
SPECIFIC_TYPE_NOT_USED
9 - Sensor binary
NOTE1: After parameter change, first exclude module
(without setting parameters to default value) then wait at
least 30s and then re include the module!
NOTE 2: W hen the parameter is set to value 9 the
notifications are send for Home Security.
Parameter no. 101
– Enable / Disable Endpoints I3 or
select Notification Type and Event
Enabling I3 means that Endpoint (I3) will be present on UI.
Disabling it will result in hiding the endpoint according to the
parameter set value. Additionally, a Notification Type and
Event can be selected for the endpoint. Available
configuration parameters (data type is 1 Byte DEC):
Endpoint device type selection:
- notification sensor (1 - 6):
GENERIC_TYPE_SENSOR_NOTIFICATION,
SPECIFIC_TYPE_NOTIFICATION_SENSOR
default value 0
1 - Home Security; Motion Detection, unknown loc.
2 - CO; Carbon Monoxide detected, unknown loc..
3 - CO2; Carbon Dioxide detected, unknown loc.
4 - Water Alarm; Water Leak detected, unknown loc.
5 - Heat Alarm; Overheat detected, unknown loc.
6 - Smoke Alarm; Smoke detected, unknown loc.
0 - Endpoint, I3 disabled
- sensor binary (9):
GENERIC_TYPE_SENSOR_BINARY,
SPECIFIC_TYPE_NOT_USED
9 - Sensor binary
NOTE1: After parameter change, first exclude module
(without setting parameters to default value) then wait at
least 30s and then re include the module!
NOTE 2: W hen the parameter is set to value 9 the
notifications are send for Home Security.
Parameter no. 110
– Temperature sensor offset settings
Set value is added or subtracted to actual measured value
by sensor. Available configuration parameters (data type is
2 Byte DEC):
default value 32536
32536 - offset is 0.0C
From 1 to 100 - value from 0.1 °C to 10.0 °C is added
to actual measured temperature.
From 1001 to 1100 - value from -0.1 °C to -10.0 °C is
subtracted to actual measured temperature.
Parameter no. 120
–Temperature sensor reporting
If digital temperature sensor is connected, module reports
measured temperature on temperature change defined by
this parameter. Available configuration parameters (data
type is 1 Byte DEC):
default value 5 = 0,5°C change
0 - reporting disabled
1 - 127 = 0,1°C - 12,7°C, step is 0,1°C
Parameter No. 250
– Unsecure / Secure Inclusion
Available configuration parameter (data type is 1 Byte Dec):
default Value 0
0
–
Unsecure Inclusion
1
–
Secure Inclusion
A Flush dimmer supports both, the secure and unsecure
inclusion. Even if the controller does not support security
command classes, a dimmer could be included as
unsecure and keep all the functionality.
Technical Specifications
Power supply
110 - 230 VAC ±10%
50 or 60Hz**,(24-30VDC)
Rated load current of AC
output
0,6A / 230VAC
Rated load current of DC
output
0,85A / 30VDC
Output circuit power of AC
output (resistive load)*
140W (230VAC)
Output circuit power of DC
output (resistive load)
21W (24VDC)
Power measurement accuracy +/-2W
Digital temperature sensor
range (sensor must be
ordered separately)
-50 ~ +125°C
Operation temperature
-10 ~ +40°C
Distance
up to 30 m indoors
(depending on building
materials)
Dimensions (WxHxD)
41,8x36,8x15,4mm
(package)
(79x52x22mm)
Weight (Brutto with package)
28g (34g)
Electricity consumption
0,7W
For installation in boxes
Ø ≥ 60mm or 2M,
depth≥ 60mm
Switching
MOSFET (Trailing edge)
*max 100W mono-phase asynchronous fan motor can be
connected to Dimmer output.
** depend on ordering code
Max Power Limit is automatically set by a software. If max
power is exceeded for more than 5 seconds, the output is
turned off up to the next power cycle of the module.When
overload occurred, Event “Over-load detected” is send to
the gateway.
Consumption in kWh is reported on every change for
0.1kWh.
Description of switch function:
Switch toggles (parameter 1 set to 1) the state of the light
bulb between the last dimming value and 0. If last dimming
value is 0 then the light is turned 100% when switch
changes its state.
Bulb types which support dimming function:
The classical incandescent bulbs.
Halogen bulbs operated by 230 V AC (High Voltage
Halogen).
Low voltage halogen bulbs with electronic or
conventional transformer.
Dimmable compact fluorescent bulb (CFL). If the bulb
at low intensities flushes, it is recommended to set
parameter 60 (minimum dimming value) to 30 or
more.
Dimmable LED bulbs.
Wave Device Class:
ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_0N
GENERIC_TYPE_SWITCH_MULTILEVEL
SPECIFIC_TYPE_POWER_SWITCH_MULTILEVEL
Z-Wave Supported Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO_V2,
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_SECURITY
Securely Supported Command Classes:
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SENSOR_BINARY_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_METER_V4
COMMAND_CLASS_SENSOR_MULTILEVEl_V7
COMMAND_CLASS_NOTIFICATION_V5
COMMAND_CLASS_MULTI_CHANNEL_V4
COMMAND_CLASS_ASSOCIATION_2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MARK
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
Endpoint 1
Device Class:
ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_0N
GENERIC_TYPE_SWITCH_MULTILEVEL
SPE SPECIFIC_TYPE_POWER_SWITCH_MULTILEVEL
Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_SECURITY
COMMAND_CLASS_ASSOCIATION_2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_METER_V4
COMMAND_CLASS_NOTIFICATION_V5
COMMAND_CLASS_MARK
COMMAND_CLASS_BASIC_V1
Endpoint 2 (I2):
Device Class:
ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_0N
GENERIC_TYPE_SENSOR_NOTIFICATION
SPECIFIC_TYPE_NOTIFICATION_SENSOR
Securely Supported Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_SECURITY
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2
COMMAND_CLASS_SENSOR_BINARY_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_NOTIFICATION_V5
COMMAND_CLASS_MARK
COMMAND_CLASS_BASIC_V1
Endpoint 3 (I3):
Device Class:
ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_0N
GENERIC_TYPE_SENSOR_NOTIFICATION
SPECIFIC_TYPE_NOTIFICATION_SENSOR
Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_SECURITY
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2
COMMAND_CLASS_SENSOR_BINARY_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_NOTIFICATION_V5
COMMAND_CLASS_MARK
COMMAND_CLASS_BASIC_V1
Endpoint 4:
Device Class:
ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_0N
GENERIC_TYPE_SENSOR_MULTILEVEL
SPECIFIC_TYPE_ROUTING_SENSOR_MULTILEVEL
Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_SECURITY
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
NOTE
:
The above list is valid for the product with a
temperature sensor connected to TS terminal. In case the
sensor is not connected then following command class isn’t
supported:
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
NOTE: The product supports the following
COMMAND_CLASS_NOTIFICATION_V5
events:
- Smoke Alarm v2
– Smoke detected, unknown loc. (0x02)
- CO Alarm v2
– CO detected, unknown location (0x02)
- CO2 Alarm
– CO2 detected, unknown loc (0x02)
- Heat Alarm v2
– Overheat detected, unknown location
(0x02)
- Water Alarm v2
– Water Leak detected, unknown
location (0x02)
- Home Security
– Motion Detection, unknown location
(0x08)
This product can be included and operated in any Z-Wave
network with other Z-Wave certified devices from any other
manufacturers. All constantly powered nodes in the same
network will act as repeaters regardless of the vendor in
order to increase reliability of the network.
Important disclaimer
Z-Wave wireless communication is inherently not always
100% reliable, and as such, this product should not be used
in situations in which life and/or valuables are solely
dependent on its function.
Warning!
Do not dispose of electrical appliances as unsorted
municipal waste, use separate collection facilities.
Contact your local government for information regarding the
collection systems available. If electrical appliances are
disposed of in landfills or dumps, hazardous substances
can leak into the groundwater and get into the food chain,
damaging your health and well-being. When replacing old
appliances with new once, the retailer is legally obligated to
take back your old appliance for disposal at least for free of
charge.
This user manual is subject to change and improvement
without notice.
NOTE
: User manual is valid for module with SW version S3
(SW version is part of P/N)! Example: P/N: ZMNHDDx
Hx
S3
Px
Qubino
Goap d.o.o. Nova Gorica
Ulica Klementa Juga 007
5250 Solkan
Slovenia
E-mail:
Tel: +386 5 335 95 00
Web:
www.qubino.com
Date: 22.07.2016
Document: Qubino_Flush Dimmer
PLUS user manual_V1.6_eng