QubicaAMF Bowler Entertainment System Installation Manual Download Page 1

PRE

-INST

ALLA

TION

MANUAL

Bowler

Entertainment

System

Bowler

Entertainment

System

M a r c h 2 0 0 7

r e v. 2 B

QUBICAAMF Europe

Bologna - ITALY

Phone: +39 051 - 4192611

Fax: +39 051 - 4192602

web: www.QubicaAMF.com

e-mail: [email protected]

Summary of Contents for Bowler Entertainment System

Page 1: ...N MANUAL Bowler Entertainment System Bowler Entertainment System M a r c h 2 0 0 7 r e v 2 B QUBICAAMF Europe Bologna ITALY Phone 39 051 4192611 Fax 39 051 4192602 web www QubicaAMF com e mail mailbox...

Page 2: ...ion 2 Ground 1 2 3 connection 10 Section A Tables 11 Table A1 RDB Power Supply 11 Table A2 RDB with LCD Consoles Power Supply 12 Table A3 Front Desk and Back Office PC Power Supply 13 Table A4 XS Bump...

Page 3: ...th Infrared Micro II Console 31 Table B13 Overhead Monitors with Infrared Micro I Console One Receiver 32 Table B14 Overhead Monitors with Infrared Micro I Console Two Receivers 33 C Structural Requir...

Page 4: ...t The electrical safety of the equipment is obtained only when the equipment is connected to an effective GROUNDING SYSTEM in accordance with the existing electrical codes and safety regulations It is...

Page 5: ...for the remainder A 1 System Components A 1 1 RDB Graphic Unit A dedicated 120V 20A 240V 10A 50 60 Hz circuit for each couple of RDB units 4 lanes is required US Only Three wire circuit with continuou...

Page 6: ...f Front Desk PC plus Monitor is 500 Watts A single power line must be set up for each Front Desk or Back Office Computer A 1 6 Back Office Computer Provisions are required in the back office to locate...

Page 7: ...Hz circuit with a continuous insulated third wire Green equipment ground connecting to the service entrance positive earth ground is required A single power line must be set up every 60 lanes Q DAC Un...

Page 8: ...oblems with the monitor images mainly due to a bad ground During the score installation on the pair of lanes there can be different connections to ground which depend on the electrical wiring of the b...

Page 9: ...the ground of the bowling building is in bad condition You must take into account an incorrect connection of the neutral on the metal support structure through the chains or any other possible bad gr...

Page 10: ...ng the chains of the metal structure one obtains a separation of grounds 1 and 2 3 The isolating of ground 1 allows the system to be worked upon with only grounds 2 3 In this way the RDB the monitor e...

Page 11: ...HIC UNIT MAX 100W INRUSH CURRENT 20A 120V 10A 220V FRONT DESK OR BACK OFFICE COMPUTER MAX 400W INRUSH CURRENT 20A 120V 10A 220V RDB NETWORK HUB INRUSH CURRENT 20A 120V 10A 220V INDICATIVE POWER CONSUM...

Page 12: ...MAX 100W INRUSH CURRENT 20A 120V 10A 220V FRONT DESK OR BACK OFFICE COMPUTER MAX 400W INRUSH CURRENT 20A 120V 10A 220V RDB NETWORK HUB INRUSH CURRENT 20A 120V 10A 220V INDICATIVE POWER CONSUMPTIONS R...

Page 13: ...ack Office Table A3 B E S Pre Installation March 2007 INDICATIVE POWER CONSUMPTIONS FRONT DESK PC MAX 400W INRUSH CURRENT 20A 120V 10A 220V TO ADDITIONAL STATION POWER SOURCE N L Front Desk Optional D...

Page 14: ...CONSUMPTIONS BUMPER INTERFACE INRUSH CURRENT 20A 120V 10A 220V AIR COMPRESSOR INRUSH CURRENT 20A 120V 10A 220V POWER SOURCE N L Air Compressor not supplied by Qubica Transformer supplied by Qubica 1 t...

Page 15: ...B E S Pre Installation March 2007 TO NEXT FOUL LIGHT UNITS TRANSFORMERS POWER SOURCE N L INDICATIVE POWER CONSUMPTIONS FOUL LIGHT INRUSH CURRENT 20A 120V 10A 220V RDB RDB Curtain W all Each transform...

Page 16: ...TCS Q DAC Table A6 B E S Pre Installation Curtain W all March 2007 TCS Q DAC MAX 100W INRUSH CURRENT 20A 120V 10A 220V INDICATIVE POWER CONSUMPTIONS POWER SOURCE N L TCS Q DAC Unit Q DAC...

Page 17: ...Q COM Q DAC Table A7 B E S Pre Installation Curtain W all March 2007 Q COM Q DAC MAX 100W INRUSH CURRENT 20A 120V 10A 220V INDICATIVE POWER CONSUMPTIONS POWER SOURCE N L Q COM Q DAC Unit Q DAC...

Page 18: ...Qubica supplies the Main RDB Switch the two additional slave switches one kit of cables for a 18 lanes center one kit for a 16 lanes center and three Cat 5 300 feet 90m cable coils one for each switch...

Page 19: ...etter interfaces and bumper interfaces are mounted on the curtain wall or in other locations near the RDB there is no need for long cable connection between them The connection between RDB and Tvision...

Page 20: ...e Installation March 2007 2 PVC Conduit 2 PVC Conduit 2 PVC Conduit Electrical Conduit along the Curtain Wall Curtain W all 2 PVC Conduit Tvision Foul Light RDB Console Pinspotter Front Desk Audio Vid...

Page 21: ...Conduits for Separated Groups Table B2 B E S Pre Installation March 2007 2 PVC Conduit 2 PVC Conduit Front Desk Audio Video Source Main RDB Switch Slave RDB Switch Slave RDB Switch...

Page 22: ...RDB Network Table B3 B E S Pre Installation March 2007 MAIN RDB SWITCH POWER SOURCE N L 98 4 ft 82 ft 82 ft 65 6 ft 49 2 ft 32 8 ft 32 8 ft 9 8 ft 9 8 ft 32 8 ft 32 8 ft 49 2 ft 65 6 ft 82 ft 82 ft...

Page 23: ...than 30 lanes Table B4 B E S Pre Installation March 2007 SLAVE RDB SWITCH MAIN RDB SWITCH SLAVE RDB SWITCH FRONT DESK Terminal 1 POWER SOURCE N L POWER SOURCE N L POWER SOURCE N L TO NEXT GROUPS MAX...

Page 24: ...e Table B5 B E S Pre Installation To RDB Main Netw rk Switch o RDB N L t Audio Ou Vide Out o M1 M2 M3 H X O R H X O R M1 M2 M3 Monitor Cables M1 Red M2 Green M3 Blue L O M C V ION T IS tt Pinse er I a...

Page 25: ...M A E T B WL NG O I I S E V E C S R E LAN V R E E S IC S B K C A SPA E C R D E K Y E O S P T L E H P IT W C S H Y E R NT C ES R O T C C E R R S E O C C R R CT E O E L B W R O T E R R O C C EAM T I G W...

Page 26: ...es M1 Red M2 Green M3 Blue ESC C E T R C O R C S R O E R C E C T R O W O R B E L O C E T C RR M EA T W N B I O G L S E R E C S VI N A L E E E C R S S VI C BA K C SP E A R D E Y KE OP T S E H LP T I SW...

Page 27: ...W N B I G O L S E R E C S VI N A L E E E C R S S VI C BA K C SP E A R D E Y KE OP T S E H LP T S I W CH T N E Y R SC E CT OR C RE S OR C E T RR C O C E E B L W O R R T C R O C E A T M E B N O I G L W...

Page 28: ...L t Audio Ou Vide Out o M1 M2 M3 H X O R H X O R M1 M2 M3 Monitor Cables M1 Red M2 Green M3 Blue PWR QA PW C R D2 M5 W P R D2 Yellow M5 Blue PWR Gray LCD Console Cables L O M C V ION T IS tt Pinse er...

Page 29: ...ut o M1 M2 M3 H X O R H X O R M1 M2 M3 Monitor Cables M1 Red M2 Green M3 Blue L W R P R PW R QA PW C R D1 M4 W L P R D2 M5 RPWR D1 Grey D2 Yellow M4 Red M5 Blue PWR Gray LCD Console Cables L O M C V I...

Page 30: ...M A E T B WL NG O I I S E V E C S R E LAN V R E E S IC S B K C A SPA E C R D E K Y E O S P T L E H P IT W C S H Y E R NT C ES R O T C C E R R S E O C C R R CT E O E L B W R O T E R R O C C EAM T I G...

Page 31: ...M1 Red M2 Green M3 Blue ESC C E T R C O R C S R O E R C E C T R O W O R B E L O C E T C RR M EA T W N B I O G L S E R E C S VI N A L E E E C R S S VI C BA K C SP E A R D E Y KE OP T S E H LP T I SW C...

Page 32: ...E B N O I G L W I R E S V S E C AN L E R C S I S V E E BA K C S A E P C D E R KEY OP T S LP E H SW CH T I T N E Y R ESC C E T R C O R C S R O E C RE C T R O W O R B E L O C E T C RR M EA T W N B I G O...

Page 33: ...W N B I G O L S E R E C S VI N A L E E E C R S S VI C BA K C SP E A R D E Y KE OP T S E H LP T I SW CH T N E Y R E C S C E T R C O R C S R O E R C E C T R O W O R B E L O C E T C RR M EA T W N B I G O...

Page 34: ...iddle of the lanes When more groups of lanes are present the hubs are each placed at the middle of groups on the curtain wall C 1 3 OHRX OHRGB OHVGA Interface The OH interfaces are located on the fals...

Page 35: ...B E S BOWLER ENTERTAINMENT SYSTEM Pre Installation Manual Copyright 2007 Qubica S p A March 2007 rev 2B 35 C 1 5 Front Desk PC C 1 6 Micro Console...

Page 36: ...B E S BOWLER ENTERTAINMENT SYSTEM Pre Installation Manual Copyright 2007 Qubica S p A March 2007 rev 2B 36 C 1 7 Fly Console C 1 8 LCD Arch Console...

Page 37: ...7 87 1470mm 28 28 47 95 1218mm 52 36 1330mm 56 69 1440mm 43 39 1102mm 42 04 1068mm 36 06 916mm 34 80 884mm 1 9 4 9 4 9 5 m m 3rd POINT REQUESTED SAFETY CHAIN 300 Lbs 300 Lbs FRONT BACK 10 24 260mm 11...

Page 38: ...290mm 65 67 1668mm 59 76 1518mm 53 86 1368mm 47 95 1218mm 43 39 1102mm 42 04 1068mm 36 14 918mm 71 57 1818mm 85 82 2180mm 10 23 260mm 11 42 290mm 28 28 28 1 9 4 9 4 9 5 m m 90 75 2305mm 19 69 500m m 3...

Page 39: ...1600mm 13 330mm 14 17 360mm 68 11 1730mm 59 76 1518mm 53 86 1368mm 47 95 1218mm 43 62 1108mm 42 05 1068mm 36 14 918mm 34 80 884mm 2 3 0 3 5 8 5 m m 69 29 1760mm 24 40 620m m 3rd POINT REQUESTED SAFET...

Page 40: ...1102mm 47 95 1218mm 53 86 1368mm 59 76 1518mm 65 67 1668mm 71 57 1818mm 77 48 1968mm 83 39 2118mm 89 29 2268mm 103 15 2620mm 13 330mm 14 17 360mm 34 34 34 109 25 2775mm 2 3 0 3 5 8 5 m m 24 41 620m m...

Page 41: ...14 60 371mm 14 97 380mm 79 53 2020mm 59 76 1518mm 53 86 1368mm 47 95 1218mm 43 62 1108mm 42 05 1068mm 36 14 918mm 34 80 884mm 2 5 7 9 6 5 5 m m 79 53 2020mm 28 34 720m m 3rd POINT REQUESTED SAFETY CH...

Page 42: ...le C6 B E S Pre Installation CHAINS ARE NOT SUPPLIED BY QUBICA FOR POST INSTALLATION SERVICE DUTIES PLEASE ALLOW SUFFICIENT GAP ABOVE MONITORS FOR SERVICE PERSONNEL SIDE UP ANGLE ADJUSTMENT 3rd POINT...

Page 43: ...Double Plasma Screens Table C7 B E S Pre Installation 300 Lbs 300 Lbs 136 Kg 136 Kg March 2007...

Page 44: ...154 36 11 16 931 MAX 36 11 16 931 MAX 28 13 16 732 MIN 28 13 16 732 MIN SPECIFICATION SPECIFICATION FRAME WEIGHT 3TV 185Lb 84Kg FRAME WEIGHT 3TV 185Lb 84Kg MAX WEIGHT CAPACITY 170Lb 77Kg PER TV MAX WE...