Quatro SPH Vac Series Instruction & Maintenance Manual Download Page 8

QUATRO    

Air Technologies Inc. 

 

Replacement Filter Part Numbers 

Qty 

Description 

Part No. 

Filter Stage 

Optional Pre Filter Pad Kit (6 Pack) 

F069-220 

Stage 1 

Optional Pre Filter Pad Kit (12 Pack) 

F069-71 

Stage 1 

Optional Knock Out Pad Kit (12 Pack) 

AG168 

Stage 1 

Optional Knock Out Pad Kit (25 Pack) 

AG169 

Stage 1 

Dust Filter (6 Pack) 

F071-BX 

Stage 2 

HEPA Filter 

F074 

Stage 3 

Odour Filter (Most Applications) 

AG097 

Stage 4 

Odour Filter Refill Kit 

AG119 

Stage 4 

Gel Repair/Replacement Kit 

AR020 

N/A 

Filter Gasket (40’ Roll) 

H296 

N/A 

 
The Quatro System can be equipped with many filter sequences. The filters shown on the above table are the most popular 
general filter sequence that work in most applications. Verify the filter(s) in your Quatro System for the correct part numbers 
before ordering.  

 

General Filter Maintainence Guide:  

Stage 

Filter 

Reccomended Filter Change Interval 

iSeries Control Panel 

Dust Or KO Pad 

Every 3 Months 

None 

Dust 

Every 6 Months 

None 

HEPA 

Every 6-18 Months 

“Service Filters” Flashing 

Odour 

Every 6-18 Months 

“Service Filters” ON 

  

7- MOTOR SERVICE & REPLACEMENT  

LED Diagnostic Table - 

“Service Motor(s)” Alerts  

If “Service Filter(s)” alert is ON SOLID the motor(s) need to be serviced or replaced.  

 

MOTOR ACCESS

 

WARNING:  Switch unit off and unplug power cord from wall before servicing the motor(s). 
The motor(s) are accessed through the bottom access pane.   
REMOVE ALL FILTERS BEFORE TURNING THE UNIT OVER TO ACCESS THE MOTORS.  

 

 

 

 

 

 

 

 

 

“Quick Change” Brush Motor 

 

 

“Infinity” Brush Motor   

 

 

Brushless Motor  

 
 

Determine which type of motor your system has installed and follow the service or replacement instructions. 
ONLY the “Quick Change” Motor Brushes can be replaced in the field (motor brushes can be replaced).   

 

IMPORTANT NOTE FOR UNITS EQUIPPED WITH 

“INFINITY” MOTORS:

 In cases of heavy production 

(continuous 

hours of daily operation)

, the brushes on the INFINITY Motors may wear before the warranty is over.  

Please note this is NOT considered a warranty issue. Motor life is a function of hours used and filter maintenance. 
They are designed to operate 1500-2000 hours and then replaced.  

In some extreme cases motor life can even be less than 1500 hours and this is usually due to the system being run at a 
high pressure (dirty filters) for extended periods of time. 

 

Quick Change 
Brush 
 
  

Infinity Curved 
Motor Brush 
 
  

Motor Access 
Panel 
 
 
  

Summary of Contents for SPH Vac Series

Page 1: ...tors Instruction Maintenance Manual READ AND UNDERSTAND THIS MANUAL BEFORE OPERATING THE SYSTEM STORE THE MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE THIS MANUAL CONTAINS CRITICAL OPERATING INFORMATION WHICH IF NOT FOLLOWED COULD CAUSE DAMAGE TO THE SYSTEM NOT COVERED BY WARRANTY ...

Page 2: ...isture water or rain Use only on a grounded electrical circuit Do not install or operate the system in an enclosed space or against a wall Unit may overheat shut down Keep all objects at least 6 away from the casing especially the discharge grill All filters must be in place whenever this machine is in operation ALWAYS turn system on off switch to off and disconnect power prior to accessing unit r...

Page 3: ...ollowing page to understand the meanings of the LEDs and the alarms Alarms Status Conditions Alarm Mute Feature All alarms can be muted for a period of 8 hours OPERATING TIME After 8 hours the alarm will return and can be muted again When mute is enabled L1 Flashes the muted alarms stay SOLID The level of the alert will not be displayed until the 8 hour mute period is over To mute Press SPD UP DN ...

Page 4: ...g Slowly Beep Every Hour Filter Pressure Near Critical Service Becoming Urgent Replace Filters Continued Operation May Result In Unit Shutdown High Pressure Causes Excess Motor Heat Accelerates Brush Wear See Filter Service Replacement Section For More Info Filter Service Replacement Instructions Flashing Slowly Beep Every Second Critical Pressure Unit Has Shutdown To Prevent Damage From Excess Pr...

Page 5: ... the AE427 QUATRO Universal Remote Cable QUATRO has some custom remote cables for specific applications Contact us for more info on available applications and part numbers The Quatro System supports Closed Contact 1 30V AC or DC remote operation as well as Remote Status signals Switching power to control the QUATRO System system remotely WILL NOT WORK and can damage the unit Temporary ON Mode Allo...

Page 6: ...ipment must be set or programmed to shut itself off when the Quatro Run signal is OPENED Contact your equipment manufacturer to verify if your equipment supports that function The status signals can either return a signal provided by your equipment or output a 12VDC or 12VDC depending on how the AE427 remote cable is wired The Quatro System uses a single common for both the Run Fault Signals To re...

Page 7: ...ollow the filter order on the inside of the access door This filter sequence can be customized for your application Disposal of both odour and particulate filters is the responsibility of the end user Please contact local authorities for proper and legal disposal of spent filters Odour Filter Refilling The odor filter does not have to be replaced It can be refilled with new filtration media FOR SY...

Page 8: ...ON 7 MOTOR SERVICE REPLACEMENT LED Diagnostic Table Service Motor s Alerts If Service Filter s alert is ON SOLID the motor s need to be serviced or replaced MOTOR ACCESS WARNING Switch unit off and unplug power cord from wall before servicing the motor s The motor s are accessed through the bottom access pane REMOVE ALL FILTERS BEFORE TURNING THE UNIT OVER TO ACCESS THE MOTORS Quick Change Brush M...

Page 9: ...ads located both sides of the motor access panel This should be done every time the brushes are changed for 2 motor units of ever second time for single motor units 6 Close motor access panel 7 For units with Basic Controls plug in power cord and run the unit with the hose disconnected for 20 minutes at minimum speed This is a break in period for the brushes and is required to properly seat the br...

Page 10: ...ASHING QUICKLY 6 Press SPEED DN 1 Time until Service Motor s LED is FLASHING 7 Press HOLD POWER button while Service Motor s LED is FLASHING unit is BEEPING continuously 8 Release when LED stops FLASHING stops BEEPING Replacement Motors Part 120V Quick Change SPH416 SPH426 AF416 AF426 Single AB001 230V Quick Change SPH415 SPH425 AF415 AF425 Single AB002 120V Infinity SPH426L AF426L Kit 2 Motors AB...

Page 11: ...ble for any loss or damage No person firm or corporation is authorised to assume for QUATRO any other liability in connection with the sale of these goods Equipment parts and material manufactured by others and incorporated in QUATRO s equipment are warranted by QUATRO only to the extent of the original manufacturer s liability to QUATRO Air Technologies Inc Conditions and Limitations This warrant...

Page 12: ...QUATRO Air Technologies Inc 12 ...

Page 13: ...QUATRO Air Technologies Inc 13 ...

Page 14: ...QUATRO Air Technologies Inc 14 ...

Reviews: