© Quatro Air Technologies| MAY 2019 | All rights reserved |
iVAC Premium Series Operation and Maintenence Manual
Page 25
Motor Service and Replacement
•
Hold for 10+ seconds, when panel is beeping continuously, release buttons.
•
You are now in RESET MENU, in this condition, “System ON” Led is FLASHING QUICKLY.
•
Press SPEED DN
(1 Time) until
“Service Motor(s)
” LED is FLASHING.
•
Press and HOLD POWER
button while
“Service Motor(s)
LED is FLASHING and unit is BEEPING
continuously.
•
Release, when LED stops FLASHING and stops BEEPING.
Replacement Motors
Part #
Quantity Required
iVac Compact & iVac1
Quantity Required
iVac 2
120V “Infinity” (iVCL, iV1L, iV2L)*
AR175
1
*2
230V “Infinity” (iVCL, iV1L, iV2L)*
AR176
1
*2
120v Brushless Motor
AB045-16
--
1
230v Brushless Motor
AB045-26
--
1
*ALWAYS Replace Both Motors At The Same Time In An iV2 so the brush wear rates stay in sync.
* In cases of heavy production
: (continuous hours of daily operation)
, the brushes on the INFINITY motors may wear
before the 1 year of warranty is over. Please note this is NOT considered a warranty issue. Motor life is a function of hours
used and filter maintenance. They are designed to operate 2000-2500 hours and then replaced.
In some extreme cases motor life can even be less than 2000 hours and this is usually due to the system being run at a
high pressure (dirty filters) for extended periods of time.