LED Diagnostics Table, R18  

Light 

(LED) 

Status 

Audible 

Alert 

Condition 

Description/Action 

 

System  SOLID 

 

Unit is ON 

 

LED 1 

(L1) 

Flashing 

Slowly 

 

AUDIBLE ALERT 

MUTED 

Alarm Condition MUTED, See L2, L3 Or L4 for specific alarm condition

 

Service 

Motors 

LED 2 

(L2) 

SOLID 

Beep 

Every 

4 Hrs 

Motor(s) Will Soon 

 Need Service 

“Quick Change” Brush Motors WILL SOON Require Brush Replacement 

INFINITY motor Brush WILL SOON Require Complete Replacement 

Brushless Motors Are Almost At The End Of The Predicted Service Life 

RESET ALERT After Service!!

 

See “Motor Service & Replacement” Section For More Motor Info & Reset Alert 

Instructions

 

 

SOLID 

Beep 

Every 

15 Min 

Motor(s) Service 

Becoming Urgent 

“Quick Change” Brush Motors ONLY: Replace Brushes ASAP And 

RESET 

ALERT, 

See “Motor Service & Replacement” Section For More Info & Reset 

Alert Instructions 

 

SOLID 

Beep 

Every 5 

Min 

Motor(s) Service 

Required 

IMMEDIATELY 

“Quick Change” Brush Motors ONLY: Replace Brushes IMMEDIATELY And 

RESET ALERT

 

See “Motor Service & Replacement” Section For More Info & Reset Alert 

Instructions 

 

SOLID 

 

Motor Alarm Muted 

L1 Flashing Slowly

 

Replace Brushes OR Motor(s) ASAP And RESET ALERT 

Alarm Mute Details On Previous Page 

See “Motor Service & Replacement” Section For More Motor Info & Reset Alert 

Instructions 

Service 
Filter(s) 

LED 3 

Flashing 

Slowly 

 

*Filter Pressure High 

Prepare To Replace/Service Filters 

See “Filter Service & Replacement” Section For More Info & Filter 

Service/Replacement Instructions 

 (L3) 

Flashing 

Slowly 

Beep 

Every 

Hour 

*Filter Pressure Near 

Critical, Service 

Becoming Urgent 

Replace Filters. See Filter Service/Replacement For More Info. 

Continued Operation May Result In Unit Shutdown. 

High Pressure Causes Excess Motor Heat & Accelerates Brush Wear. 

 

Flashing 

Slowly 

Beep 

Every 

Second 

*Critical Pressure 

Unit Has Shutdown

 To Prevent Damage From Excess Pressure 

Verify Blockage – Remove Blockage 

Verify All Filters – Clean/Replace Filters Accordingly 

See “Filter Service & Replacement” Section For More Info 

 

SOLID 

Beep 

Every 

Hour 

Filter(s) Service Life 

Expired 

Replace Filter(s) ASAP And RESET ALERT 

See “Filter Service & Replacement” Section For More Info & Reset Alert 

Instructions 

 

SOLID 

 

Filter Alarm Muted 

L1 Flashing Slowly

 

Replace Filter(s) ASAP And RESET ALERT 

Alarm Mute Details On Previous Page 

See “Filter Service & Replacement” Section For More Info & Reset Alert 

Instructions 

Remote 

Standby 

SOLID 

 

Receiving Remote 

Signal 

Remote Switch Closed (On) OR Receiving Remote Signal From Another Piece 

Of Equipment 

LED 5 

(L5) 

Fading 

IN-OUT 

 

Shutdown Delay 

Quatro System Continues To Run For A Short Period To Remove All Debris 

From Work Area 

 

Flashing 

Slowly 

 

Unit Is In Standby 

Waiting For Remote Switch To Close (Turn On) OR To Receiving Remote 

Signal From Another Piece Of Equipment 

ALL 

LEDS 

Flashing 

Slowly 

Beep 

Every 

Second 

* Low System Pressure 

Abnormally Low Pressure, Unit will BEEP & 

Shutdown In 5 Seconds

 

Unit Will Continue To Shutdown Unit Until The Issue Is Addressed 

-Motor(s) Not Operating Due To Service Required Or Failure  

Service (Change Brushes) Or Replace Motor(s) & RESET ALERT Alert 

 See “Motor Service & Replacement” Section For More Motor Info & Reset Alert 

Instructions 

-Motors Not Operating Due To Excess Heat.  

Check For Line Blockage, Service/Replace Filters. Let Motor(s) Cool For 

30Min.  

See “Filter Service & Replacement” Section For More Info & Reset Alert 

instructions, -Access Door(s) Open. Close All Access Doors 

-Filters Not Or Improperly Installed. Verify Filters 

Summary of Contents for PowerStation PS6 Series

Page 1: ... dia use thick gaskets around Rubber hose Fittigns to make up the dimension Your option to install unit on 6 stationery rubber feet or 4 mobile casters install 2 lockable casters in front 1 Install Rubber feet or casters 2 Open filter door remove plastic around HEPA filter install HEPA filter Grating and filter bags 3 Plug Power Cord to a grounded 240 volt wall outlet 4 Connect to individual works...

Page 2: ...ck Easy Remote Start Stop Valves that reduce Dust Collector power consumption ASVs allow more suction to the active workstations by diverting air from the idle ones Principle of Operation 1 START STOP dust collector when you OPEN CLOSE valve 2 CLOSE valve when not using workstation OPEN valve when using dust collector 3 Install as many ASVs as you like Dust collector STARTS automatically if AT LEA...

Page 3: ...pect concealed damages inside the box indicate so on the transport companies shipping documents Single box c w all components required either on or inside the unit PRE START UP CHECKLIST a Check that all internal components are present and are adequately supported b Check that labels and serial numbers are present for future identification c Verify power supply compatibility with equipment 120 vol...

Page 4: ... will be OFF and unit will be ready to operate again Resetting Microprocessor After Filter Replacement WHILE Service Filters Led is OFF 1 Ensure motor access door is closed 2 Plug power back to the unit 3 When you Press POWER MOTOR WILL START 4 While motor is operating press hold SPEED UP DN simultaneously until unit BEEPS hold for 10 seconds when beeping continuously release 5 In this condition S...

Page 5: ...ower supply Circuit breaker popped Motor burnt Brushes worn Check breaker box RESET circuit breaker on unit panel Replace motor PN AB001 Replace Brushes PN AB112 Excessive noise Turbine impeller contacting housing Replace motor PN AB001 Insufficient airflow Obstruction in system Clogged filter Remove obstruction Replace filter Motor shuts off Input amperage too high Graphite crystal rods are consu...

Page 6: ...oming Urgent Replace Filters See Filter Service Replacement For More Info Continued Operation May Result In Unit Shutdown High Pressure Causes Excess Motor Heat Accelerates Brush Wear Flashing Slowly Beep Every Second Critical Pressure Unit Has Shutdown To Prevent Damage From Excess Pressure Verify Blockage Remove Blockage Verify All Filters Clean Replace Filters Accordingly See Filter Service Rep...

Reviews: