Quatro CollectALL MedEVAC MultiPure PowerStation... Operation & Maintenance Manual Download Page 6

QUATRO        

Air Technologies Inc. 

----------------------------------------------------------------

 Engineers Of Clean Air

 ----------------------------------------------------------------

 

30 Hymus Boulevard, Montreal, Quebec, H9R 1C9     Tel.: (514) 630-4444   Fax: (514) 630-4454   website: 

www.quatroair.com

   [email protected] 

Suction varies from workstation to 
workstation 

  Hose lengths between stations vary 

 

Adjust damper or blast gate at each station equalizing suction 

WARRANTY 

QUATRO Air Technologies (QUATRO) warrants its equipment to be free from defect in material and workmanship under 
normal use and service for a period of one year from date of shipment.  QUATRO's obligation under this warranty shall be 
limited to replacing any parts, thereof, which shall be demonstrated to have been defective.  This is expressly in lieu of all 
other warranties, express or implied, including the warranties of merchantability and fitness. 
QUATRO claims no warranty as to merchantability or as to the fitness of the merchandise for any particular use and shall not 
be liable for any loss or damage.  No person, firm or corporation is authorised to assume for QUATRO any other liability in 
connection with the sale of these goods.  Equipment, parts and material manufactured by others and incorporated in 
QUATRO's equipment are warranted by QUATRO only to the extent of the original manufacturer's liability to QUATRO. 
Conditions and Limitations:    

This warranty does not cover

 abuse, misuse, maintenance negligence, improper assembly, 

acts of vandalism, acts of God, fear wear, modifications of the equipment or installation of a part not recommended by 
QUATRO, as well as operation of the equipment at voltages other than those specified by QUATRO

REPLACEMENT PARTS LIST 

 

CollectALL 

MedEVAC MultiPure 

PowerStation2 

Description 

CA- 

MMP- 

PS216- 

HEPA Filter  

F074 

F074 

F074 

Filter Bags (2/pak) 

AG259-02 

AG259-02 

Filter Bags (6/pak) 

AG149 

AG259-06 

AG259-06 

Filter Bags (12/pak) 

AG259-12 

AG259-12 

Odor Container Refill  

 

NC-GPC 

Rhodium Odor Refill 

NC-BPC 

Solder Fume Odor Refill 

NC-GPC 

 

 

Rhodium & Solder Fume Odor Refill 

F109 

Blower Turbine Assy 120V 

(2) AR175 

(2) AR175 

(2) AR175 

Blower Turbine Assy 230V 

(2) AR176 

(2) AR176 

(2) AR176 

Brushless Turbine Assy (120v) 

(1)AB045-16 

(1)AB045-16 

(1)AB045-16 

Brushless Turbine Assy (230v) 

(1)AB045-25 

(1)AB045-25 

(1)AB045-25 

 

 

 

 
 
 
 
 

Summary of Contents for CollectALL MedEVAC MultiPure PowerStation...

Page 1: ...unit 6 ft long hose INSTALLATION 1 Open filter door remove plastic around HEPA filter and Odor Filter if applicable 2 Ensure filter bags are properly installed fit into 2 tubes beneath the top of fil...

Page 2: ...companies shipping documents Single box c w all components required either on or inside the unit PRE START UP CHECKLIST a Check that all internal components are present and are adequately supported b...

Page 3: ...t stops BEEPING 8 Led will be OFF and unit will be ready to operate again BLOWER MAINTENANCE INFINITY MOTORS NO BRUSH CHANGE REQUIRED This unit is equipped with an Automatic Motor Optimization System...

Page 4: ...et design See the beginning of the Motor Service Replacement Section 5 Install the bracket on the new motor If the bracket is installed incorrectly it may result in a short to ground for the brush con...

Page 5: ...r s Led stays SOLID 4 While motor is operating press hold SPEED UP DN simultaneously until unit BEEPS hold for 10 seconds when beeping continuously release 5 In this condition System ON Led is FLASHIN...

Page 6: ...sed to assume for QUATRO any other liability in connection with the sale of these goods Equipment parts and material manufactured by others and incorporated in QUATRO s equipment are warranted by QUAT...

Page 7: ...ming Urgent Replace Filters See Filter Service Replacement For More Info Continued Operation May Result In Unit Shutdown High Pressure Causes Excess Motor Heat Accelerates Brush Wear Flashing Slowly B...

Page 8: ...n removed Remote has a shutdown delay of approximately 5 10 seconds Flashing None Unit is in Standby mode waiting for remote signal or mc2 signal if provided to start unit Low System Pressure Flashing...

Reviews: