3.2.1Viewing Resource Settings with Device Manager
1. Start the Windows
95/98/ME
Device Manager
.
2. Double click on the hardware class
Quatech Comm Adapters
to list hardware
devices in the class.
3. The SSP-200/300 “parent device” belongs to this hardware class. The device name
for the SSP-200/300 is
Quatech SSP-200/300: RS-422/RS-485 Serial Port PC
Card.
4. Open the
Properties
dialog for the SSP-200/300 device, then click the
Resources
tab
to view the Input/Output Range and Interrupt Request resource allocations.
5. Double click the hardware class
Ports (Com and LPT)
. The
Quatech
Communications Port
listed in this class is a “child device” of the SSP-200/300
“parent device.”
6. Open the
Properties
dialog for the COM port, then click the
Resources
tab to view
the Input/Output Range and Interrupt Request resource allocations. These will match
those of the “parent device.”
7. Record the COM Port device name (COM1, COM2, etc.) for the SSP-200/300. This
name is required by a Windows
95/98/ME
application when accessing a particular
port.
3.2.2Changing Resource Settings with Device Manager
1. Start the Windows 95/98/ME
Device Manager
.
2. Double click on the hardware class
Quatech Comm Adapters
to list hardware
devices in the class.
3. The SSP-200/300 “parent device” belongs to this hardware class. The device name
for the SSP-200/300 is
Quatech SSP-200/300: RS-422/RS-485 Serial Port PC
Card.
4. Open the
Properties
dialog for the SSP-200/300 device, then click the
Resources
tab
to view the Input/Output Range and Interrupt Request resource allocations.
5. Several predefined
Basic Configurations
have been included for the SSP-200/300
(see Figure 5. SSP-200/300 Basic Configuration Table). The Basic Configurations
provide many combinations of the operating modes and options listed below. See the
Hardware Information
section of this manual for complete descriptions.
RS-422/485 output drivers enable option: The SSP-200/300’s ports may be
configured for either full duplex or half duplex operation with this option. The
default setting is the RS-422/485 ports are configured for full duplex operation with
the RS-422/485 output drivers always enabled. In half duplex mode, the RS-422/485
3-3
SSP-200/300 (Rev. I and later) User's Manual
Summary of Contents for SSP-200
Page 6: ...This page intentionally left blank 2 1 SSP 200 300 Rev I and later User s Manual ...
Page 18: ...This page intentionally left blank 3 1 SSP 200 300 Rev I and later User s Manual ...
Page 24: ...This page intentionally left blank 4 1 SSP 200 300 Rev I and later User s Manual ...
Page 31: ...Windows 2000 4 8 ...
Page 33: ...Windows 2000 4 10 ...
Page 38: ...This page intentionally left blank 5 1 SSP 200 300 Rev I and later User s Manual ...
Page 48: ...This page intentionally left blank 7 1 SSP 200 300 Rev I and later User s Manual ...
Page 50: ...This page intentionally left blank 8 1 SSP 200 300 Rev I and later User s Manual ...
Page 52: ...SSP 200 300 User s Manual Revision 3 12 March 2004 P N 940 0075 312 Quatech Inc ...