Note that just turning the RF output on does not guarantee that RF is output. If there is not a valid clock (or in clock
free, if there is no valid data (transitions) from which to derive a clock), then the RF output is Off (unless the unit
has the AC option and the AC command is enabled, in which case a carrier on the current center frequency is
output).
Also, if the unit has an RF On/Off pin that is pulled into the Off state (determined by the current setting of RZ), then
there is no RF output.
Also refer to Appendix C – Understanding Clock/Data, AC, and BR.
4.2.1.1.14 RF Output State
– RFS
The RFS command may display the following information, depending on available options, about the connected
transmitter:
RFS
ModCtrlReg shdw = 00007003h
GPIO_In_reg = 5C02FF37h
BB_ctl_reg = 00000890h
CF_auto_ctl_reg = 00000000h
pa_ctrl_shadow = 00000006h
RF pin = 1
RZ 1 (high = RF on) PA Intfc NOT detected
DP opt 0
PL 1 bb interface: RS422
CF opt 1
CF Normal
EN option 0 EN state 0
AC opt 1
ACS opt 0
AC Off
FO opt 1
AI opt 0
AI state disabled
SC 2
CE opt 1
RH opt 0
NRF opt 0
LD opt 1
LD6 opt 1
BB rate: 5.000 Mbps
OTA rate: 5.000 Mbps
MO 0 FR 1812.5 MHz FO 0.068 MHz SD 100
CS 0 DS 0 IC 5.000
ID pattern currently: PN23
BR 5.000 Mbps (Auto)
RF 1 CC 0 MC 0 MS 1.000
LP 0.0
HP 31.5
DE 0 RA 0 CP A DP 0 SI 0 VP 31.5
bb_clk_okay: 1
clock free bitrate: N/A
Power Level = 31.5 dB
DL: 4400
i dac: 5075 q dac: 11362 iqr: -7.0 dB
Tmpcmp Enabled
DL chk Enabled
Synth locked
RF State: On
Desired RF: On
Last Dsrd RF: On
LDPC Off code 2
BB rate: 5.000 Mbps
OTA rate: 5.000 Mbps
PA_RF_state = 0
TX Enable : 1
Bias Enable: 1
24V Run: 0
Synth_en = TRUE
Mod_en = TRUE
Vin_fault_detected = 0
T4 Atten 0.0 dB
PA Atten2 31.5 dB
4.2.1.1.15 Set Configuration Priority
– SC
The SC command sets or shows the current configuration priority setting. When the transmitter is first powered on,
it loads the default configuration from preset 0. Based on the setting of the SC parameter, the transmitter may look
for a digital switch box sign-on and then attempt to read the frequency, mode, and LDPC settings from the switch
box. This command requires the DSWBX (digital switch box) option to be valid.
Valid SC settings are:
•
1 – Read the switch box (frequency plug) on power up; thereafter, changes from either the switch box or
Terminal interface are allowed.
•
2 – Ignore the switch box (frequency plug) ALWAYS; Only the Terminal interface works until the SC
setting changes.
The default value is SC 1 if the DSWBX option is present on the transmitter.
The default value is SC 2 if the DSWBX option is NOT present on the transmitter.