Firmware Update Procedure 

for the 

3

rd

 Generation Rack-Mount RDMS™ Telemetry Receiver 

 

 

 

 

 

 

Quasonix, Inc. 

6025 Schumacher Park Dr. 

West Chester, OH 45069 

04 October 2018 

 

Revision 1.1.2 

 
 
 

Specifications subject to change without notice. 

All Quasonix products are under U.S. Department of Commerce jurisdiction; not covered by ITAR 

 

Summary of Contents for RDMS

Page 1: ...pyright Quasonix Inc All Rights Reserved Firmware Update Procedure for the 3rd Generation Rack Mount RDMS Telemetry Receiver Quasonix Inc 6025 Schumacher Park Dr West Chester OH 45069 04 October 2018...

Page 2: ...6 Browser Interface About 3 Figure 7 About System Version Firmware Update Link 4 Figure 8 Firmware Update Procedure and Notes 4 Figure 9 Firmware Update Upload Status 5 Figure 10 Firmware Update File...

Page 3: ...completely powered down remove the cover from the front panel to access the USB Micro SD ports as shown in Figure 1 Figure 1 Front Panel USB Micro SD Port Access 2 Insert the programming card supplied...

Page 4: ...a 3U receiver to start the programming cycle Programming will take about 45 minutes At the end of the programming cycle you will be prompted to remove the SD card and cycle power on the RDMS 6 Turn th...

Page 5: ...elease of all versions after R15 Note The R15 update is a gatekeeper release and must be performed prior to updating to R16 or beyond If required please contact Quasonix to request an R15 update card...

Page 6: ...dure and Notes as shown in Figure 8 5 Click on the Browse button to select the update file provided by Quasonix Figure 8 Firmware Update Procedure and Notes 6 After the selected filename displays clic...

Page 7: ...ate Upload Status 7 After the file has been transferred review the updated Notes as shown in Figure 10 8 Click on the Begin Update button to start the update No further input will be required unless a...

Page 8: ...ogress Status The RDMS front panel indicates that an update is currently being performed as shown in Figure 12 Figure 12 Front Panel Network Update Status Messages The RDMS will reboot twice during th...

Page 9: ...en on the front panel then select System Info as shown in Figure 14 to verify that the System Version matches the firmware update version Figure 14 System Settings System Info If the update fails for...

Page 10: ...beyond If required please contact Quasonix to request an R15 update card To perform a local update 1 Obtain a firmware update file from Quasonix 2 Transfer the update file to the root directory of a...

Page 11: ...he front panel displays the Perform Local Update screen as shown in Figure 18 Figure 17 Perform Local Update Screen 5 Select OK then press Enter to start the update The front panel displays the RDMS3...

Page 12: ...e During the update a status displays as shown in Figure 20 The RDMS will reboot twice during the update After the first reboot the front panel displays are automatically updated first This update may...

Page 13: ...Firmware Update Procedure for RM Receivers 11 Quasonix Inc Figure 21 System Settings System Info...

Page 14: ...Firmware Update Procedure for RM Receivers 12 Quasonix Inc 2 Maintenance Instructions The Rack Mount Receiver requires no regular maintenance and there are no user serviceable parts inside...

Page 15: ...Firmware Update Procedure for RM Receivers 13 Quasonix Inc 3 Product Warranty The Rack Mount Receiver carries a standard parts and labor warranty of one 1 year from the date of delivery...

Page 16: ...hipment Authorized return shipments must be addressed in the following manner Quasonix Inc ATTN Repair RMA 6025 Schumacher Park Drive West Chester OH 45069 To ensure that your shipment is processed mo...

Reviews: