Rack-Mount RDMS
TM
Telemetry Receiver
151
Quasonix, Inc.
5 Performance Specifications
5.1 RF Input
Each receiver channel is available in multiple band configurations, as shown in Table 11.
Table 11: Band Codes and Frequencies
Model Number
Code
Band
Minimum
Frequency
Maximum
Frequency
Default
Frequency
P
P band (UHF)
400.0 MHz
1150.0 MHz
400.0 MHz
L
Lower L
1435.5 MHz
1534.5 MHz
1435.5 MHz
U
Upper L
1755.0 MHz
1850.0 MHz
1755.0 MHz
S
S
2200.5 MHz
2394.5 MHz
2200.5 MHz
C
C “Low”
4400.0 MHz
5150.0 MHz
4400.0 MHz
G
P and S (Dual band)
400.0 MHz and
2200.5 MHz
1150.0 MHz and
2394.5 MHz
2200.5 MHz
F
S and C (Dual band)
2200.5 MHz and
4400.0 MHz
2394.5 MHz and
5150.0 MHz
2200.5 MHz
M
Lower L, Upper L, and
S (Tri-band)
1435.5 MHz
2394.5 MHz
1435.5 MHz
R
P, Full-L, and S
(Quad band)
400.0 MHz
2394.5 MHz
1435.5 MHz
Q
Full L, S, and C
(Quad band)
1435.5 MHz
5150.0 MHz
1435.5 MHz
E
P, Full L, S, and C
(Five band)
400.0 MHz
5150.0 MHz
400.0 MHz
The input impedance is 50 ohms.
5.2 Power
The rack-mount receiver requires 100 to 240 VAC, 50/60 Hz power.
5.3 RF Frequency Error
By default, the RDMS™ is capable of acquiring a signal with a frequency error of up to ±100 kHz.
5.4 Bit Error Rate
The RDMS™ meets the following BER limits, when tested with a signal source, which complies with IRIG 106-05.