Figure 66: I and Q Data Streams Independently Encoded
The appropriate decoder for this method is selected by setting Convolutional Symbol to Disabled (unchecked), as
shown in Figure 65. In older releases without the Convolutional Symbol control, this was the only method
supported.
The second method is for I and Q data to be created from the G1 and G2 generators, respectively, of a single
convolutional encoder. In this method, only one convolutional encoder is used for both the I and Q data.
Figure 67: I and Q Data from Single Convolutional Encoder
The appropriate decoder for this method is selected by setting Convolutional Symbol to Enabled (checked), as
shown in Figure 68.