GENERAL RELAY INFORMATION 

 

We accept no responsibility for injury, loss, or damage of any kind caused by or resulting from improper product assembly, testing, commissioning or use.

 

Warning! Risk of Electric Shock!

 

This information concerns kits and modules with relay outputs. TO USE THE RELAY OUTPUTS 
SAFELY YOU MUST OBSERVE THE MAXIMUM VOLTAGE AND CURRENT LIMITS QUOTED 
IN THE 

PRODUCT DOCUMENTATION 

(this is because the board design may not be rated to 

switch the maximum voltage and current limits printed on the relay itself or specified in the relay 
manufacturer’s data sheet). 
Controlling mains equipment with relay outputs must be treated with extreme caution. Electric 
shocks can cause severe and permanent injury or even death. Construction, installation, testing and commissioning 
should only be attempted by suitably qualified persons, or under the supervision of a suitably qualified person. These 
products are not suitable for children. Before connecting mains powered equipment to the relay outputs please check 
with the relevant authorities in order to ensure compliance with all current safety regulations.  
Many areas of the assembly may operate at mains voltage. A suitable isolating enclosure must be used. Exposed screw 
terminal blocks on some products must be insulated to prevent contact with exposed metallic parts at mains potential. 
Connected equipment should be suitably fused.

 

 
You will find relay outputs on many of the kits and modules that we sell. A relay is an electrically 
operated on/off switch. The voltage and current limits specified in the product documentation 
generally relate to resistive or light inductive loads. 
 

Relay Terminals 

Most boards have SPDT (Single Pole Double Throw) style relays. These have three outputs: 
 

C

 = Common 

NO

 = Normally-Open contacts connect the circuit when the relay is activated; the 

circuit is disconnected when the relay is inactive. It is also called a Form A 
contact or "make" contact. 

NC

 = Normally-Closed contacts disconnect the circuit when the relay is activated; 

the circuit is connected when the relay is inactive. It is also called a Form B 
contact or "break" contact. 
 
 

Connecting the Device you want to Control 

You must provide an external power source to the device you want to control. No voltage is present at 
the relay terminals (remember it is just a switch). The relay is normally connected in 

series

 with the 

positive (+) power wire of the device you want to control.  
 
In this case, the positive wire from the power source should be connected to Common. Then either 
the NO or NC terminal (as appropriate for your purpose) is connected to the positive (+) wire going to 
the device you want to control. The negative (-) wire does not connect to the relay at all. It goes 
directly from the power source negative output to the device negative (-) terminal. 
 

Typical SPDT Relay Connection Diagrams 

 

 

Anti-Spark SPDT Relay Connection Diagram 

Sometimes the connected equipment can cause arcing across the relay contacts. This must be 
corrected by installing a resistor and capacitor (not supplied) between the two contacts of the relay as 
shown below. Component values are for 230Vac mains. 

 

Summary of Contents for 3140

Page 1: ...perated equipment complies with these safety hints Use a suitable plastic enclosure If a metal enclosure is used make sure it is properly earthed Use a power switch if the device consumes more than 10...

Page 2: ...d DTMF digit is detected the 4 bit code is placed on pins 11 14 and a data avaliable output pin 15 is set to a logic high The output relays RL1 4 are controlled via the relay driver IC6 One output fro...

Page 3: ...w quasarelectronics com jpg 3140_2 jpg PRE TESTING Insert IC7 MAX666 and connect a 12 15Vdc power supply to the DC input jack Use a multimeter to check the 5V supply Easiest place to measure this is a...

Page 4: ...this feature is disabled the unit expects the the call to be answered externally eg by an answering machine Everything else works as normal including entering a valid password The only difference is...

Page 5: ...lder BT wiremen is often approaching art in its perfection The BT Drop Cable The cable coming from the outside world This often has Orange White Green and Black wires Usually but not always Orange and...

Page 6: ...5V electrolytic C9 1 Semiconductors 1N4004 diode D1 2 3 3 1N4148 D4 1 WO2 B1 2 3 3 Diode bridge MJE340 NPN transistor Q1 1 MPSA42 NPN transistor Q2 1 CM8870 datasheet from California Micro Devices www...

Page 7: ...t we sell A relay is an electrically operated on off switch The voltage and current limits specified in the product documentation generally relate to resistive or light inductive loads Relay Terminals...

Page 8: ...QUASAR CODES 3140 DTMF Telephone Relay Switcher Page 7...

Reviews: