1  Safety Considerations 

1.1  General 

This product and related documentation must be reviewed for familiarisation 
before  operation.  If  the  equipment  is  used  in  a  manner  not  specified  by the 
manufacturer, the protection provided by the instrument may be impaired. 

1.1.1  Before Applying Power 

Verify that the product is set to match the available  charger and the correct 
fuse is installed. 

1.1.2  Before Cleaning 

Disconnect the product from operating power before cleaning. 

WARNING  

Bodily  injury  or  death  may  result  from  failure  to  heed  a 
warning.  Do  not  proceed  beyond  a  warning  until  the 
indicated conditions are fully understood and met. 

 

CAUTION 

Damage  to  equipment,  or  incorrect  measurement  data, 
may result from failure to heed a caution. Do not proceed 
beyond  a  caution  until  the  indicated  conditions  are  fully 
understood and met. 

1.2  Voltage, Frequency and Power Characteristics 

1.2.1  Universal Full Range AC Input Power Adaptor 

Class II power (no earth) 

Overvoltage, short circuit & over temperature protection 

GS, UL/cUL & CE approval 

Voltage 100 - 240V AC  

Summary of Contents for E10-GPS

Page 1: ...4 December 2013 Page 1 E10 GPS Disciplined Rubidium Frequency Reference USER S HANDBOOK Quartzlock UK Ltd Gothic Plymouth Road Totnes Devon TQ9 5LH England Tel 44 0 1803 862062 Fax 44 0 1803 867962 We...

Page 2: ...Model E10 GPS Operation Manual E10 GPS Manual A5 4 December 2013 Page 2 Revision Date Description By 1 1st Nov 2013 Initial Release N Law...

Page 3: ...ersal Full Range AC Input Power Adaptor 4 1 2 2 Unit Power Requirements 5 1 3 Environmental Conditions 5 1 3 1 Temperature 5 1 3 2 Magnetic Field 5 1 4 Cleaning Instructions 5 2 Rubidium Frequency Ref...

Page 4: ...1 2 Before Cleaning Disconnect the product from operating power before cleaning WARNING Bodily injury or death may result from failure to heed a warning Do not proceed beyond a warning until the indi...

Page 5: ...o C to 40o C 1 3 2 Magnetic Field Sensitivity 2x10 11 Gauss Atmospheric Pressure 60m to 4000m 1x10 13 mbar 1 4 Cleaning Instructions To ensure long and trouble free operation keep the unit free from d...

Page 6: ...as high on the researchers agenda This was mainly due to an understanding that such a device would have extremely good short term stability relative to size and price In 1964 Davidovits brought such r...

Page 7: ...operates differently and is not affected The thermal stability of Rubidium is inferior to that of Caesium or Hydrogen Masers and the Rubidium previously required frequency access to a primary referenc...

Page 8: ...y 3 2 Getting Started Check that the appropriate supply voltage is being used Connect the external supply to the unit at the rear and switch on Switch on the unit via the front panel switch the ON ind...

Page 9: ...me 100ns relative to GPS or Ext input 25 2 Holdover a no GPS Frequency 5E 12 day b Time 1 s 24 hours 3 Short Term Stability a 3E 11 1s b 1E 11 10s c 3E 12 100s 4 Phase Noise a 100dBc 10Hz b 130dBc 100...

Page 10: ...ing a Via Serial Port Software for PC Export UTC time b Export the location of the local place including longitude latitude and length c Export the model of the Atomic Oscillator d Export the version...

Page 11: ...Voltage 15V DC 1 7A 18 Warm Time 25o C 5 Minutes to lock 19 Retrace 2x10 11 20 Magnetic Field Sensitivity 2x10 11 21 Mechanical a Size 103 x 55 x 122 mm b Weight 500g 22 Warranty 24 months 23 Tempera...