Voltage, Frequency and Power Characteristics 

Voltage 220-240V AC  

Frequency 40-50Hz   

Power characteristics 500mA Max

  

Environmental Conditions  

Temperature 

Operating (ambient) 

-10°C to +55°C (-65 to +65 op) 

Storage 

-40°C to +85°C 

Magnetic Field 

Sensitivity 

2x10

-11

/ Gauss 

Atmospheric Pressure 

-60m to 4000m 

 <1x10

-13

/ mbar 

Replaceable Fusing Characteristics 

800mA time-lag HBC 

Cleaning Instructions 

To ensure long and trouble operation, keep the unit free from dust and use care with liquids around the unit. 

Be careful not to spill liquids onto the unit. If the unit does get wet, turn the power off immediately and let the unit dry completely 
before turning it on again. 

Clean with a damp (with water) cloth. 

Never spray cleaner directly onto the unit or let liquid run into any part of it. Never use harsh or caustic products to clean the unit. 

Distribution Amplifier A5000 

Operating Procedure 

Introduction 

The Quartzlock model A5000 is a distribution amplifier designed for standard frequency distribution between 1 MHz and 100 MHz.  

Input 

One input is provided. This has input impedance of 50 . The input level should be between 0 and +13 dBm. 

Outputs 

Up to six outputs are provided. These have source impedance of 50 , and will provide between 0 and +13 dBm into a 50  load. 