12
Quartet Battery Adapter
Copyright © 2001 QTI
Safety Features
Introduction
The
Battery Adapter
contains two internal
non-replaceable
fuses to protect from:
•
Reverse input protection
•
Over voltage input
•
Catastrophic failure
•
Shorted Outputs
•
Battery Adapter Input Power Cable Fuse
Reverse Input Protection
The
Battery Adapter
features a reverse input protection circuit in the event the input
from the
Battery Adapter Input Power Cable
is connected improperly.
Over Voltage Input
The
Battery Adapter
has been designed to withstand transient voltages up +60VDC
that last up to a millisecond in length.
Catastrophic Failure
In the event the
Battery Adapter
fails, the internal fuse will “blow” to protect the
Battery Adapter
. If this happens, the unit will have to be returned for repair.
Shorted Outputs
In the event the +12VDC and/or the +9VDC outputs becomes shorted, the
Battery
Adapter
will automatically trip an internal fuse and shut the outputs down.
If this happens, you
must
remove the +24VDC input by disconnecting the
Battery
Adapter Input Power Cable
for
at least
1 minute. Be sure to remove the “short”
before reattaching the
Battery Adapter Input Power Cable.
Battery Adapter Input Power Cable Fuse
The
Battery Adapter Input Power Cable
includes a built-in replaceable fuse shown
as (A) below:
Use only a Littlefuse 2A Mini Fuse type if replacement is needed.