background image

PM9113-0-0  Revision 2

Product Manual

Model 9113-0-0

Ethernet Bridge

for Ultra 3000 Servo

Quartech Corporation

15923 Angelo Drive

Macomb Township, Michigan 48042-4050

Phone:  (586) 781-0373   FAX: (586) 781-0378

   www.QuartechCorp.com

PM9113-0-0 Revision 2

The product described in this document can have a variety of uses, the user and those responsible for applying this
equipment must satisfy themselves as to the acceptability of each application and the use of the unit.  Under no
circumstances will QUARTECH CORPORATION be responsible or liable for any damage, including indirect or
consequential losses resulting from the use, misuse, or application of the unit.

The text, illustrations, charts, and examples included in this document are intended solely to help explain applications
of the product.  Due to the many variables associated with specific uses or applications, QUARTECH CORPORATION
cannot assume responsibility or liability for actual use based upon the data provided in this document.

No patent liability is assumed by QUARTECH CORPORATION with respect to the use of circuits, information,
equipment, or software described in this document.

This document is subject to change without notice.

Summary of Contents for 9113-0-0

Page 1: ...UARTECH CORPORATION be responsible or liable for any damage including indirect or consequential losses resulting from the use misuse or application of the unit The text illustrations charts and exampl...

Page 2: ...ile Element numbers The 9113 can perform scaling that allows your PLC program to work in scaled values such as inches or RPMs Individual scale values exist for position velocity and acceleration type...

Page 3: ...ding Once a session is established between the 9113 and PLC it can remain indefinitely providing both devices remain wired powered and active Once a session is established the 9113 expects the PLC to...

Page 4: ...he network but must match the node set in the 9113 The 9113 is configured by the factory to access Ultra node zero which is the default for a new Ultra 3000 drive The node used by the 9113 can be modi...

Page 5: ...ord between a device and a hub or switche Crossover cables are used to connect two devices directly without a hub or switch Odd numbered pins are always striped even numbered pins are always solid col...

Page 6: ...d with 9113 9 Pin Male D Type Ultra 3000 Communication Parameters 38400 Baud 8 Data Bits No Parity One Stop Bit 2181 Cable 9113 to Personal Computer This cable is required when using serial port utili...

Page 7: ...has caused a session to expire The LED will flash green while at least one session is active Refer to the theory of operation topic for more information about sessions If switch four is on and switch...

Page 8: ...made through a specific port subsequent access will be allowed only through that port until the 9113 is re powered Fault LED The fault LED is valid only during normal run mode If the internal Fault Re...

Page 9: ...he clip to the bottom of the DIN rail Lift upward while tilting back then release so that the top of the clip catches the top of the DIN rail EN500 22 35 DIN Rail To remove lift upward tilt forward th...