background image

 

 

 

Quark-elec Manual                                                     

 

 

 

https://www.quark-elec.com

 

4  of  8 

2018 

V2.0 

4. Connecting via USB port 

AT011 is supplied with a USB connector. This connector provides power supply and data input for 
configuration. This USB connector can be linked directly to a USB port on the PC.   

 
Windows:

 To enable the USB data connection of AT011 to other devices, related hardware drivers 

may be needed dependent on your system requirements. 

Windows 7,8,10

 the driver can be found on the CD in the packing box or be downloaded from 

https://www.quark-elec.com 
The AT011 registers itself to the computer as a virtual serial com port.   
The drivers usually install automatically to your device if it is running an original Windows 10 version. 
A new COM port will automatically show up in the device manager after plug in. 
 

Mac:

 For Mac OS X, the AT011 will be recognized and shown as a USB modem. The ID can be 

checked with the following steps: 
1.  Plug the AT011 into a USB port and launch Terminal.app.   
2.  Type: less /dev/*sub* 
3.  The Mac system will return a list of USB devices. AT011 will display as - 

“/dev/tty.usbmodemXYZ” 

where XYZ is a number. Nothing further needs to be done if it is listed. 

 

Linux:

 No driver is required for Linux. When plugged into the computer, AT011 will show up as a USB 

CDC device on /dev/ttyACM0. 
 

4.1. 

Checking the USB connection (Windows) 

After the driver is installed, run the Device Manager and check the 

COM number

 (this is the number 

associated with the USB port you are using. The port number is the number that Windows assigns as 
an input device. These can be generated randomly by 
your computer). Your chart software may require your 
COM number in order to access the data.   
 
The port number for the AT011 can be found in 
Windows ‘Control Panel->System->Device Manager’ 
under ‘Ports (COM & LPT)’. Find the AT011 in the list 
for the USB variant. To change this number, double 
click the AT011 

and select the ‘Port Settings’ tab. Click 

the ‘Advanced’ button and change the port number to 
the one required. 
 
 
 

Checking the USB data flow:

 If desired, the USB data can always be checked with a terminal 

monitor application, like Putty or HyperTerminal. To do this, enter the following into the COM port 
settings: 

Bits per second: 38400bps

Data bits: 8

Parity: None

, and 

Stop bits: 1

 as shown below 

using HyperTerminal on Windows as an example 
 
 
 
 

 

Summary of Contents for QK-AT011

Page 1: ...K AT011 AIS Transmit Simulation Terminal Manual Features USB 2 0 powered 5 0V Working on two AIS frequencies 161 975MHz 162 025MHz BNC output Configurable location information Configurable transmit me...

Page 2: ...om 2 of 8 2018 V2 0 1 Contents 1 Contents 2 2 Introduction 3 3 Connecting 3 4 Connecting via USB port 4 4 1 Checking the USB connection Windows 4 5 Configuration 5 6 Status LED S 5 7 Operating 6 8 Lim...

Page 3: ...ing an AIS transmission simulator The unit needs a 5V power supply and can be controlled using a PC USB interface Once the unit has been programmed it can be disconnected from the PC to be used in sit...

Page 4: ...ll display as dev tty usbmodemXYZ where XYZ is a number Nothing further needs to be done if it is listed Linux No driver is required for Linux When plugged into the computer AT011 will show up as a US...

Page 5: ...eded and can be downloaded from the Quark elec website at same as A021 023 https www quark elec com product a023 ais wireless receiver For Windows 10 the system will recognize and install the driver a...

Page 6: ...e repeat message has been send out By un plugging from the USB and plugging it back in again The terminal will reset and continue the repeat message again The red LED will turn on after power up The g...

Page 7: ...com 7 of 8 2018 V2 0 Figure 3 An example on OpenCPN For more technical information and other enquiries please go to the Quark elec forum at https quark elec com forum For sales and purchasing informat...

Page 8: ...the products user or their estate for any accident loss injury or damage whatsoever arising out of the use or of liability to use this product Quark products may be upgraded from time to time and fut...