Quark-Elec QK-AS07-0183 Quick Start Manual Download Page 2

QK

-

AS07

-

0183

 

AS07

-

0183 INSTALLATION

 

 
 

                     

 

                       

 

 
 
 

The AS07 connects directly to your 12v power and NMEA 0183 device. No other connections or 
configuration is generally required.

 

 

1.   Mounting: Consider your locations

 

• 

Sturdy outdoor location, with 

line of sight

’ 

to the sky.

 

• 

The AS07

-

0183 has a standard G3/4 thread and is supplied with a corresponding base.

 

• 

If drilling holes for screws and cabling, seal around any holes to prevent damage to your 
vessel or equipment.

 

 

2.   Installation

 

 

The AS07

-

0183 is designed to be used out of the box, for instant positional data to other NMEA 

0183 devices. The default baud rate has been set as 4800bps, at 1Hz updating frequency.

 

 

2.1   Connections

 

 

 

Ensure power is turned OFF when connecting any wire of your device

 

 
 

The AS07

-

0183 sensor has the following five wires.  Connect the yellow wire (RX) 

with the Black (thin one, GND) one, if it isn

t used.  

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Wire

 

Function

 

Red

 

12V

-

24V POWER

 

Black (thin)

 

GND

 

Black (thick)

 

GND (shield)

 

Green

 

NMEA OUT / RS232 TX

 

Yellow

 

NMEA IN / RS232 RX

 

This is an overview only. Always familiarize yourself with the product manual and 
the  manuals  of  any  connecting  devices  before  installation.  Designed  to  be 
connected by an experienced installer.

 

USING THE OPTIONAL USB OUTPUT

 

QK

-

AS07 –

0183 

 

 

  

2.2 Connecting to NMEA 0183 (RS232) devices

 

The AS07

-

0183 sends positional sentences, in the NMEA 0183

-

RS232 (single

-

ended) protocol.

 

For RS232 interface devices , these wires need to be connected.

 

 

 
 
 
 
 
 
 
 
 

TAKE CARE: There may be two GND connections on your connecting NMEA 0183

-

RS232 device. One is GND for the NMEA Connection and one is GND for Power.

 

Ensure you check the above table and your device

s documentation carefully before 

connection.

 

 

2.3  Connecting to NMEA 0183 (RS422) devices

 

Although AS07

-

0183 sends out NMEA 0183 sentences via single end RS232 interface, it also sup-

ports RS422 (differential signal) for RS232 interface devices, these wires need to be connected

 

 
 
 
 
 
 
 

 

QK

-

AS07

-

0183 

wire

 

Connection needed on RS232 

device

 

NMEA0183

 

Green: TX (NMEA 
OUT)

 

RX (NMEA IN)

 

 

Black (thick): GND 
shield

 

GND (sometimes called COM)

 

POWER

 

Black (thin): GND

 

GND (for Power)

 

 

Red: Power

 

12v—

14.4

v Power

 

 

QK

-

AS07

-

0183 

wire

 

Connection needed on RS422 

device

 

NMEA0183

 

Green: TX (NMEA 
OUT)

 

NMEA IN

-

 (sometimes called 

NMEA/B or 

-

Ve)

 

 

Black (thick): GND 
shield

 

NMEA IN+ (sometimes called 
NMEA/A or +Ve)

 

POWER

 

Black (thin): GND

 

GND (for Power)

 

 

Red: Power

 

12v—

14.4

v  Power

 

Reviews: