Quark-Elec AS06 User Manual Download Page 9

 

 

 

QK-AS06 Manual                                                     

 

 

 

V 1.0 

9  of  11 

2021 

 

1.  Open the configuration tool 

2.  Select your COM port number, which can be found in your 

‘Device Manager’ 

on your computer 

3. 

Click ‘

Open

’.

 In case of successful connection, the 

‘Connected’ 

status will appear in the bottom left 

corner of the configuration window and the current firmware will be displayed in the bottom right 
corner. Now, the configuration tool is read to be used. 

4. 

Click ‘

Read

’ to read the device’s current settings

5. 

Configure the settings as required: 
 

 

NMEA 0183 Baud Rates

.

 

‘Baud rate’

 refers to the data transfer speed. The AS06

’s

 output 

port’s default baud

 rate is 4800bps. However, the baud rate can be changed to 

9600bps,38400bps,115200bps if required. 

When connecting two NMEA 0183 devices, both devices’ baud rates must be set to the 

same speed. Select the baud rate to match 

the other device’s (e.g. chart plotter, multiplexer, 

etc.) baud rate. 

 

Wind angle deviation. 

The AS06 anemometer must be 

oriented forward, towards the bow of the boat and the displayed 
wind angle value should be 0° in order to obtain meaningful 
data. Due to the position of the wind sensor after installation and 
the slight discrepancy between the arm and the 0° position of 
the wind angle sensor, the reading might show a slight 
difference compared to the true value. This value can be 
adjusted if required, to get accurate wind angle data. 

 

Wind speed calibration code. 

PL

EASE DON’T change this 

value, unless instructed by a Quark-elec technical team 
member or an authorized distributor. The AS06 comes with a 
calibrated wind speed sensor. 

 

Output messages(reserved). 

The current version of the AS06 outputs wind speed data in 

‘MWV’ sentence

 format, however the updated 

version will support heading data in ‘HDM’ and 

‘HDG’

 sentence format. The new AS06 will have a data filtering function, so it will be possible 

to filter out unwanted NMEA0183 messages. 

 

 

6. 

Click ‘

Config

 and please wait for a few seconds to ensure the new setting have been saved. 

7. 

Click ‘

Read

’ to 

check if the settings have been 

saved correctly before clicking ‘

Exit

’.

 

8.  Disconnect the AS06 from the power supply. 

9.  Disconnect the AS06 from the PC. 

10. 

Re-power the AS06 to activate the new settings. 

Summary of Contents for AS06

Page 1: ... 107 knots 0 to 55m sec direction from 0 to 359 Waterproof enclosure IP66 rating Designed for harsh conditions Pre calibrated and configured Quick and simple installation Data output in NMEA 0183 MWV sentence format NMEA 2000 data interface AS01 NMEA 2000 gateway required not included in the box Robust fixing bracket Low power consumption 27mA Re calibration possible if required ...

Page 2: ... features a cup anemometer with 3 cups for speed and a pre balanced vane for direction measurement providing a reliable and robust solution for marine applications The AS06 has been pre calibrated and can be used out of the box to provide instant wind speed and direction data to NMEA 0183 devices or to the NMEA 2000 backbone AS01 NMEA 2000 mini gateway required not included With the ceramic bearin...

Page 3: ...unted at least 2 m 7 ft above the ground and consistent with meteorological conditions for the application The AS06 cable should be secured with cable ties to protect it from damage Secure the mast the AS06 is mounted on so that it does not vibrate Installing a lightning rod nearby can reduce the risk of damage caused by lightning The sensor can be damaged by improper handling Store the sensor in ...

Page 4: ...e damage to the AS06 2 The AS06 must be substantially horizontal and the arm should be pointing straight forward Spirit level not included can be used to obtain the right position Position can also be adjusted from the two screws on the D bracket After the installation is complete please ensure fixing screws are tightened and the D bracket is well fixed and secured to the mast 3 3 Secure the cable...

Page 5: ...he above table and your device s documentation carefully before powering up 4 3 Connecting QK AS06 to NMEA 0183 RS422 devices Although AS06 uses single ended RS232 interface it also supports RS422 differential signal interface devices In this case devices have to be connected in the following way 2 Swap NMEA input and NMEA input wires if the communication does not work The following is an example ...

Page 6: ...le 0 to 359 degrees 2 Reference R Relative T True 3 Wind Speed 4 Wind Speed Units K M N 5 Status A Data Valid V Invalid 6 Checksum Example sentence IIMWV 214 8 R 5 1 K A 33 6 Maintenance The AS06 was designed to be maintenance free for the first 4 years of use While the outer surface could show some signs of surface corrosion with time in salty maritime or harsh environments the inner bearings mec...

Page 7: ...bearing resistance due to dirt entering the anemometer s bearing or the bearing is possibly worn out if it has been in use for several years Please be advised calibration service and bearing replacement should be performed only by Quark elec authorized distributors and trained personnel to maintain warranty validity 7 Configuration via USB The AS06 is designed to be used out of the box If required...

Page 8: ...return a list of USB devices The AS06 will be displayed as dev tty usbmodemXYZ where XYZ is a number Nothing further needs to be done if your device is listed Linux No driver is required for Linux When plugged into the computer the AS06 will show up as a USB CDC device on dev ttyACM0 Windows 7 8 10 Drivers usually are installed automatically if your computer is running an original Windows 10 versi...

Page 9: ...and the displayed wind angle value should be 0 in order to obtain meaningful data Due to the position of the wind sensor after installation and the slight discrepancy between the arm and the 0 position of the wind angle sensor the reading might show a slight difference compared to the true value This value can be adjusted if required to get accurate wind angle data Wind speed calibration code PLEA...

Page 10: ...utput data rate 4 8k to 38 4kbps RS 422 galvanically isolated Operating Temperature 35 C to 65 C Environmental Rating Weatherproof IP66 Storage Temperature 30 C to 70 C Recommended Humidity 0 93 RH 9 Limited warranty and notices Quark elec warrants this product to be free from defects in materials and manufacture for two years from the date of purchase Quark elec will at its sole option repair or ...

Page 11: ...vided with this product Document history Issue Date Changes Comments 1 0 02 12 2021 Initial release 08 01 2022 10 Glossary NMEA 0183 is a serial data interface operating at 4 8 Kbit second utilizing standard asynchronous communications It is an electrical and data standard for communication between marine electronics NMEA2000 N2K is a serial data network operating at 250 Kbit second utilizing the ...

Reviews: