background image

Quantum Scalar LTFS Appliance: Power Supply Replacement

6-68095-01 Rev A

December 2013

Removing a Failed Power Supply

3

Removing a Failed Power Supply

To remove the failed power supply, complete the following steps:

1

Look at the LED indicators on the power supply: when an amber LED is 

displayed or the LED is OFF, that power supply has failed (see 

Figure

 

1

).

2

When disconnecting the power cable, remove the cable from the strap.

3

Remove the power supply cable from the failed power supply.

4

Press the release latch and use the power supply handle to help remove the 

power supply from the Scalar LTFS Appliance.

Caution:

The power supply may be hot. Use caution when removing the 

failed power supply.

Figure 1  Remove the Scalar 
LTFS Appliance Power Supply

Connector

Power
Supply

Release
Latch

Power
Supply
Handle

Status LED 

(Step 1)

Velcro strap 

(Step2)

(Step 4)

I

Replacing a Failed Power Supply

To replace the power supply, complete the following steps:

1

In the empty bay of the Scalar LTFS Appliance, insert the replacement power 

supply until the release latch snaps into place.

2

Reattach the power cable to the power supply.

Summary of Contents for Scalar LTFS

Page 1: ...e subject to change Quantum Scalar LTFS Appliance Power Supply Replacement The Scalar Linear Tape File System LTFS Appliance is powered by two redundant hot swappable power supplies located in the back of the unit Once the failed power supply is identified the power supply can be easily replaced and the Scalar LTFS Appliance returned to normal operation Always replace faulty power supplies to ensu...

Page 2: ...ng to Replace a Power Supply Before beginning the replacement procedure make sure that you have the required replacement kit s Refer to the following table for the replacement kit contents see Table 1 Table 1 Scalar LTFS Appliance Power Supply Kit Illustration Description Qty Replacement power supply 570 watt 1 Required Tools None ...

Page 3: ... from the failed power supply 4 Press the release latch and use the power supply handle to help remove the power supply from the Scalar LTFS Appliance Caution The power supply may be hot Use caution when removing the failed power supply Figure 1 Remove the Scalar LTFS Appliance Power Supply Connector Power Supply Release Latch Power Supply Handle Status LED Step 1 Velcro strap Step2 Step 4 I Repla...

Page 4: ...ing properly check the power supply s LED indicators A green light indicates that a valid AC source is connected to the power supply and that the power supply is operational When Scalar LTFS Appliance is on a green light also indicates that the power supply is providing DC power to the appliance 4 When connecting the power cable secure the cable with the strap ...