background image

INSTALLATION AND PROGRAMMING MAN

file:///C|/.../PACH-CO.COM%202010-1/products/quantum%20series/quantum%20qc1/manual/system%20programming.htm[6/24/2010 10:04:59 AM]

Summary of Contents for QC1

Page 1: ...INSTALLATION AND PROGRAMMING MAN file C O COM PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual Quantum 20QC1 htm 6 24 2010 10 04 56 AM INSTALLATION AND PROGRAMMING MANUAL Rev 1 0...

Page 2: ...m the selling dealer and or installer as to the nature of the dealer s warranty if any All contact to Pach Co from the end user consumer will be referred to the consumer s selling dealer and or instal...

Page 3: ...k and bottom panel Dimension 9 3 4 L x 6 3 8 W x 1 3 4 D Features 100 access codes 4 5 6 7 8 digit and 200 cards 10 temporary access codes valid 1 10 times 10 special access codes to hold open and clo...

Page 4: ...N AND PROGRAMMING MAN file C O COM PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual Quantum 20QC1 htm 6 24 2010 10 04 56 AM Back View WIRING DIAGRAM Click on the label for more deta...

Page 5: ...4 2010 10 04 56 AM INPUT POWER BATTERY BACKUP CAMERA Input Power 12 18 VAC DC 12VAC transformer is supplied Type of wires 2 conductors 18 gauge stranded Battery Backup 12VDC 4Ahr Type of wires 2 condu...

Page 6: ...doors independently Each relay supports NO normally open and NC Normally Closed contact No power is supplied by the relays therefore you MUST supply separate power for door strike Check the voltage re...

Page 7: ...RAMMING MAN file C O COM PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual Quantum 20QC1 htm 6 24 2010 10 04 56 AM TELEPHONE WIRING DIAGRAM 1 Standard Telephone Line Wiring requireme...

Page 8: ...LLATION AND PROGRAMMING MAN file C O COM PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual Quantum 20QC1 htm 6 24 2010 10 04 56 AM 2 Using a DSL line Wiring requirements 18 gauge str...

Page 9: ...products quantum 20series quantum 20qc1 manual Quantum 20QC1 htm 6 24 2010 10 04 56 AM AUXILIARY INPUT DOOR SENSOR RS 485 AND WIEGAND DIAGRAM Wiring requirements See manufacturers specification RS 485...

Page 10: ...however if you need to use different card reader you may do so by disconnecting the existing card reader and replace with your own 26 bit wiegand card reader as shown on the diagram Warning Compatibi...

Page 11: ...og on to programming the screen will show as below SPEAKER AND MICROPHONE Speaker 8 7 ohm Microphone 1 542 kOhm RADIO RECEIVER The Quantum QR5 has built in Radio Frequency RF Receiver The transmitter...

Page 12: ...c1 manual Quantum 20QC1 htm 6 24 2010 10 04 56 AM EARTH GROUND Wiring requirement 16 18 gauge wire Connect the earth ground wire into one of the door hinge stud KEYPAD LAYOUT AND FUNCTIONALITY The Qua...

Page 13: ...INSTALLATION AND PROGRAMMING MAN file C O COM PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual Quantum 20QC1 htm 6 24 2010 10 04 56 AM...

Page 14: ...y 19 Directory Digit 38 System answer mode 04 Delete all directories 20 Aux in 1 39 Enable disable remote access 05 Enable or Disable Scroll 21 Aux in 2 40 Remote access number door1 06 New access cod...

Page 15: ...c1 manual system 20programming htm 6 24 2010 10 04 59 AM In case the master code is not available refer to Master code retrieval button then click wiring diagram link 00 Change master code It is recom...

Page 16: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 17: ...01 Call forwarding directory 10 call forwarding directories can be programmed in the system The call forwarding can be used to call direct or as an automatic call forwarding based on the programming o...

Page 18: ...e C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 02 Edit existing directory In case of making mistake on Function Code 01 then use...

Page 19: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 20: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 03 Delete a directory...

Page 21: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 04 Delete all directories...

Page 22: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 23: ...ntum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 05 Enable or Disable Scroll The and to scroll up and down will be disabled if this function code is set to Disable 0 The visitor can st...

Page 24: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 06 New access code...

Page 25: ...rogramming htm 6 24 2010 10 04 59 AM A maximum of 100 access codes can be programmed in the system The access code can be set in 4 5 6 7 and 8 digit see function code 09 default setting is 4 digit For...

Page 26: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 27: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 07 Delete access code...

Page 28: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 29: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 08 Delete all access codes...

Page 30: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 09 Access code digit...

Page 31: ...s quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM The access code can be set to 4 default setting 5 6 7 or 8 digit thru the programming once the number of digit ha...

Page 32: ...ing htm 6 24 2010 10 04 59 AM 10 New card or transmitter enrollment The Quantum QR5 has built in 26 bit Wiegand Card Reader and Radio Receiver A maximum of 100 combination of cards and transmitters ca...

Page 33: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 34: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 35: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 11 Delete card or transmitter...

Page 36: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 12 Delete all cards and transmitters...

Page 37: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 13 Set time...

Page 38: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 39: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 14 Set date...

Page 40: ...anual system 20programming htm 6 24 2010 10 04 59 AM 15 Initializing event buffer The quantum QR5 has event recording tracking capability You must use Internet Explorer browser and optional TCP IP box...

Page 41: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 42: ...e Auto unlock schedules are used to open and close the door according to the time schedules programmed in the system A maximum 10 Auto unlock schedules can be programmed in the system For example Sche...

Page 43: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 44: ...010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 17 Time Zones The Quantum QR5 has 10 time zones Time Zone 00 is 24 hours access not programmable Tim...

Page 45: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 46: ...ual system 20programming htm 6 24 2010 10 04 59 AM 18 Holiday Time Zones The quantum QR5 has 20 Holiday Time Zones It is your responsibility to maintain the holiday time zones since the holidays are n...

Page 47: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 48: ...24 2010 10 04 59 AM 19 Directory Digit The directory is a unique number that must be assigned to each tenant unit number last 4 digit of telephone number etc By default the directory digit is 2 digit...

Page 49: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 50: ...20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 20 AUX IN 1 The Auxiliary Input 1 AUXIN 1 can be use for exit switch loop detector or any dry contact input devices The AU...

Page 51: ...20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 21 AUXIN 2 The Auxiliary Input 2 AUXIN 2 can be use for exit switch loop detector or any dry contact input devices The AUX...

Page 52: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 53: ...eries quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 22 Do Not Disturb Do Not Disturb will disable the call feature on the Quantum QR5 just incase if you do not want to be disturb...

Page 54: ...uantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 23 Lock Out Count The Lock Out Count can be set 1 9 The system will be locked if invalid access master code access c...

Page 55: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 56: ...series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 24 Alarm Mode Alarm mode is associated with invalid access set on function code 23 Alarm mode can be set to DISABLE LOCAL CAL...

Page 57: ...OGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 25 Keypad Press Beep The keypad press beep can be turned On enab...

Page 58: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 26 Door Beep...

Page 59: ...AN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM The system will beep if granting access to door 1 door 2 or both doors The...

Page 60: ...m 6 24 2010 10 04 59 AM 27 Talk Time The length of time for the two party to communicate using the system The system will disconnect the call if the talk time is expired A minute before the talk time...

Page 61: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 28 Door 1 Open Time...

Page 62: ...NSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM The length of time the door 1 relay 1 will ope...

Page 63: ...N AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 29 Door 2 Open Time The length of time the door 2 relay...

Page 64: ...010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 33 Temporary Codes Up to 10 temporary codes can be programmed for limited number of used 01 10 times...

Page 65: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 66: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 67: ...manual system 20programming htm 6 24 2010 10 04 59 AM 34 Unlock Hold Door Using Special Access Code Door 1 and door 2 can be open and hold open and close using a special code A valid code must be ente...

Page 68: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 69: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 70: ...0series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 35 Temporary Card or Transmitter Up to 10 temporary cards or transmitters can be programmed for limited number of used 01 10...

Page 71: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 72: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 73: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 74: ...al system 20programming htm 6 24 2010 10 04 59 AM 36 Unlock Hold Using Card Fob or Transmitter Door 1 and door 2 can be open and hold open and close using card fob or transmitter A valid code must be...

Page 75: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 76: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 77: ...ogramming htm 6 24 2010 10 04 59 AM 38 System Answer Mode The Quantum QR5 will answer incoming call from an outside line The system answer mode must be enabled by selecting the number of ring The numb...

Page 78: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 79: ...antum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 39 Enable or Disable Remote Access The tenant can press associated keypad key to release the door or gate By default is number 9 key t...

Page 80: ...O COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 40 DTMF Opening Door 1 By default DTMF number 9 key is used to open the door 1 remotely by...

Page 81: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 41 DTMF Opening Door 2...

Page 82: ...ile C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM By default DTMF number 8 key is used to open the door 2 remotely by the tenant...

Page 83: ...ies quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 42 Relay 2 Mode Relay 2 is programmable There are four mode 1 Door Control default 2 Relay 2 triggers simultaneously as relay 1...

Page 84: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 43 Do not Disturb Time Zones...

Page 85: ...1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM It is to disable a call button according to the time zone programmed No one can call from the system 10...

Page 86: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 87: ...um 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 45 Manual Unlock Timer Using the timer door 1 and door 2 can be unlock according for an increment of one hour 01 98 hour...

Page 88: ...20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 50 Erase Memory to Default This function code will erase the memory to factory default All the programming cannot be recove...

Page 89: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...

Page 90: ...ING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM 51 Edit Welcome Screen Welcome screen consists of 3 segment and each s...

Page 91: ...INSTALLATION AND PROGRAMMING MAN file C PACH CO COM 202010 1 products quantum 20series quantum 20qc1 manual system 20programming htm 6 24 2010 10 04 59 AM...