Appendix A Library Specifications
Environmental Specifications
82
Quantum|ATL P3000 Series User’s Guide
Electrical connection
to power
IEC 320 C19 male
connector inside back door
Climatic Environment
Temperature
(operating)
Dry Bulb
15
o
C to 32
o
C (59
o
F to 90
o
F)
Wet bulb
25
o
C (77
o
F) maximum
Thermal transition
11
o
C per hour
Temperature
(shipping and
storage)
Dry bulb
-40
o
C to 66
o
C (-40
o
F to
151
o
F)
Wet bulb
46
o
C (115
o
F) maximum
Thermal transition
30
o
C (54
o
F) per hour
Relative
humidity
Operating
20% to 80%, non-
condensing
Shipping and storage
5% to 95%, non-condensing
Electromagnetic/Electrostatic Susceptibility
Altitude
Operating
Sea Level to 10,000 ft.
(3,048 m)
Shipping and storage
Sea Level to 12,000 ft.
(3,657 m)
Heat dissipation
Operating
5500 BTU/hr (1400 KCal/
hr or 1600 watts)
Direct ESD
Contact discharge
@ 2.0, 4.0, 6.0, 8.0 kV to all
external metal panels and
doors
Air discharge
@ 2.0, 4.0, 6.0, 8.0, 10.0, 12.0,
15.0 kV to the front GUI
display
Indirect ESD
Contact discharge
@ 2.0, 4.0, 6.0, 8.0 kV to the
VCP
Summary of Contents for P3000 Series
Page 1: ...Quantum ATL P3000 Series Automated Tape Library User s Guide 6311601 05 Ver 5 Rel 0...
Page 8: ...Contents viii Quantum ATL P3000 Series User s Guide...
Page 12: ...Figures xii Quantum ATL P3000 Series User s Guide...
Page 20: ...xx Quantum ATL P3000 Series User s Guide...
Page 34: ...Chapter 1 Library Description Library Components 14 Quantum ATL P3000 Series User s Guide...