Prism FC420 Blink Codes
Table 3 Blink Code
Summary
First
Blink
Digit
Second
Blink
Digit
Error
Code
Classification
Failure
Recommended
Action
Comments
1
1
Fatal
SCSI FW POST
failure
Reboot board and
record error log
1
2
Fatal
CPU POST failure
Reboot board and
record error log
1
3
Fatal
RAM POST failure
Reboot board and
record error log
2
1
Fatal
SCSI chip POST
failure
Reboot board and
record error log
2
2
Fatal
SRAM POST failure
Reboot board and
record error log
2
3
Fatal
Extended SRAM
failure
Reboot board and
record error log
3
3
Fatal
DRAM POST
failure
Reboot board and
record error log
3
4
Fatal
Extended DRAM
failure
Reboot board and
record error log
4
1
Fatal
Fibre Channel
controller
Reboot board and
record error log
4
2
Fatal/Non-
fatal/Critical
Fibre Channel
controller chip
failure
Reboot board and
record error log
Non-fatal in the
case of port failover
- if applicable (error
code BC)
Critical internal
software incident,
not a hardware
defect (error code
B3)
Fatal internal
software incident,
not a hardware
defect (error code
B4)
4
3
Fatal
Fibre Channel
controller chip
initialization failure
Reboot board and
record error log
5
2
Fatal
SCSI controller chip
1 failure
Reboot board and
record error log