Chapter 3: DXi6902 FRU Removal and Replacement Procedures
Replacing a Node Processor and Heatsink
Quantum DXi6902 User’s Guide
137
7
Similarly, position your thumb firmly over the processor socket
release lever near the lock icon, and release the lever from the
locked position by pushing down and out from under the tab.
Rotate the lever 90 degrees upward
.
Figure 84 Processor Shield
Opening and Closing Lever
Sequence
10
Rotate the processor shield upward and out of the way (see
).
Caution:
The socket pins are fragile and can be permanently
damaged. Be careful not to bend the pins in the socket
when removing the processor out of the socket.
11
Lift the processor out of the socket and leave the release lever up so
that the socket is ready for the new processor.
Close lock symbol
Processor socket
release lever
Processor
Processor socket
release lever
Open lock symbol