Quantum DXi6802 and DXi690x: Rack Mount Rails Replacement
6-68446-01
April 2016
Replacing the DXi6802 or DXi690x Node Rails
7
Figure 6 Installing the Node
2
Locate the rear rail standoff on each side of the system and lower them into
the rear J-slots on the slide assemblies.
3
Rotate the system downward until all the rail standoffs are seated in all four
of the J-slots.
4
Slide the system inward until the lock levers click into place.
5
Press the slide-release lock buttons on both rails and slide the system into
the rack.
6
Reconnect all power, SAS, Ethernet, and Fibre Channel cables on the rear of
the Node.
Note:
For cabling diagrams, see the
DXi6800 Installation and
Configuration Guide
(6-67757) at
or the
DXi690x Installation and Configuration Guide
(6-68160) at
7
Turn on the system (
8
If applicable, replace the front bezel. Insert the right side of the bezel into
the slots on the right side of the Node, then snap the left side of the bezel
into place.
Inner slide rails
Rear rail standoffs
Rear rail J-slots
Slide-release lock button
Lock lever
Locking tab
Locking tab