Quantum|ATL StackLink™ Installation Instructions
Document 6421009-03, Ver. 3, Rel. 0
November 2001
Cabling the Library
23
2
Connect the power cable (provided in the library accessories kit) to
the power inlet on the back of the library (see
) and to the
AC distribution unit.
Figure 18 Power Inlet
6-9
Select one of the following options:
• Connect no more than 5 libraries to each of
two AC distribution units rated minimum
10A, minimum 1.00mm
2
<HAR> cord with
minimum 10A plug. Must be 3 wire
grounding plug and wall outlet. The AC
distribution units must be plugged into
separate outlets served by separate circuit
breakers or fuses.
• Connect all libraries to one AC distribution
unit rated minimum 10A, minimum
1.00mm
2
<HAR> 3 wire cord with 3 wire
IEC60309 rated 16A. Must be 3 wire
grounding plug and wall outlet and have a
ground warning label.
• Connect all libraries to one AC distribution
unit rated minimum 10A, minimum 1.00
mm
2
<HAR> 3 wire cord permanently
wired to the electrical supply. Must be
connected with a 3 wire cable and have a
ground warning label.
Select one of the following options:
• Connect no more than 5 libraries to each of
two AC distribution units rated 15A or
20A, with a minimum 14AWG 3 wire cord,
and a 15A or 20A plug. Must be 3 wire
grounding plug and wall outlet. The AC
distribution units must be plugged into
separate outlets served by separate circuit
breakers or fuses.
• Connect all libraries to one AC distribution
unit rated 20A, with a minimum 14AWG 3
wire cord, with a 20A plug. Must be 3 wire
grounding plug and wall outlet.
• Connect all libraries to one AC distribution
unit rated minimum 20A, with a minimum
14AWG 3 wire cord, permanently wired to
the electrical supply.
10
Same requirements as 6-9 above.
Same requirements as 6-9 above, but the AC
power distribution unit must also have a
ground warning label.
# of
Library
Modules
Distribution Unit Requirements
200-240V 50-60Hz supply voltage (Europe
& international, etc.)
100-120V 50-60Hz supply voltage (USA,
Canada, Japan, etc.)
Power inlet