background image

ActiveScale™ P100E3 Support Guide

22

4 System specifications

This section provides the specifications for the ActiveScale P100E3. 

Topics:

System specification summary

 on page 22

P100E3 Node specifications

 on page 22

Hard disk drive specifications (P100E3 Nodes)

 on page 23

Solid state drive specifications

 on page 24

4.1  System specification summary

The following table is a summary of specifications relevant to the ActiveScale P100E3 system.

4.2  P100E3 Node specifications

The following table lists the system specifications for an individual P100E3 Node.

Table 4

-

9. System specification summary

Condition (fully configured)

Non-operating

Operating

Altitude

-984 ft to 39,371 ft

(-300 m to 12,000 m)

-984 ft to 10,000 ft 

(-300 m to 3,048 m)

Height in rack units (U)

Base configuration

—3U

Power requirements (typical/ 

maximum)

N/A

Base configuration

—1.85 to 2.03 kW

Relative humidity

20% to 95% non-condensing

20% to 80% non-condensing

Relative humidity gradient

30% per hour maximum

30% per hour maximum

System width and depth

Width

—17.6 in (448.2 mm)

Depth

—35 in (881 mm)

Temperature

-40°F to 158°F (-40°C to 70°C)

50°F to 95°F (10°C to 35°C)

Temperature de-rating

33.8°F per 984.2 ft above 9842.5 ft 
(1°C per 300 m above 3000 m)

33.8°F per 984.2 ft above 3116.8 ft
(1°C per 300 m above 950 m)

Temperature gradient

86°F (30°C)/hour

68°F (20°C)/hour

Thermal output

N/A

3-node kit

—0.665 to 0.785 KBTU/hour

Weight

Base configuration

— 180 lbs (212.4 kg)

Summary of Contents for ActiveScale P100E3

Page 1: ...ActiveScale P100E3 Support Guide 6 68925 03 Rev A with ActiveScale OS 6 0 2 software...

Page 2: ...trademarks or trademarks of Quantum Corporation and its affiliates in the United States and or other countries All other trademarks are the property of their respective owners Quantum specifications a...

Page 3: ...100E3 node mounting kit 11 2 3 1 Replaceable parts for mounting kits 11 3 Parts replacement steps 12 3 1 P100E3 node part replacement instructions 12 3 1 1 Replacing 3 5 inch drives 12 3 1 1 1 Drive r...

Page 4: ...port Guide 2 4 System specifications 22 4 1 System specification summary 22 4 2 P100E3 Node specifications 22 4 3 Hard disk drive specifications P100E3 Nodes 23 4 4 Solid state drive specifications 24...

Page 5: ...ons 11 Table 3 5 3 5 HDD replacement overview 12 Table 3 6 2 5 inch drive replacement overview 15 Table 3 7 P100E3 node PSU replacement overview 17 Table 3 8 P100E3 Node replacement overview 18 Table...

Page 6: ...ActiveScale P100E3 Support Guide List of tables 4...

Page 7: ...system layout 6 Figure 2 2 P100E3 Node 8 Figure 3 3 Drive tray release lever 13 Figure 3 4 Drive tray pulled out 13 Figure 3 5 Drive handle operation 14 Figure 3 6 Removing the 2 5 inch drive 16 Figu...

Page 8: ...eds to make before integrating the system at the site where the system will be deployed This document should be used by the systems architect system planner and site manager and teams which plan the i...

Page 9: ...maximum N A 3 node system 1 85 to 2 03 kW Relative humidity 20 to 95 non condensing 20 to 80 non condensing Relative humidity gradient 30 per hour maximum 30 per hour maximum System width and depth Wi...

Page 10: ...Mounting kits on page 11 2 1 P100E3 Node The P100E3 node provides the bulk data object storage for the ActiveScale P100E3 system Each P100E3 node is equipped with 12 hard disk drives housed in a pull...

Page 11: ...tton descriptions Number Name Description LED action 1 Power button with LED Powers the system on or off LED indicates that the component is powered on Solid blue Powered on Off Powered off 2 ID butto...

Page 12: ...has been de asserted 6 LAN1 Indicates Link or LAN1 access Solid blue Link Blinking blue LAN access off when there is traffic 7 LAN2 Indicates Link or LAN2 access Solid blue Link Blinking Blue LAN acce...

Page 13: ...s have the words LEFT and RIGHT stamped on them The rails clip into the rack rails using a tool less design 2 3 1 Replaceable parts for mounting kits The following table lists all of the replaceable m...

Page 14: ...that is in the Decommissioned state Important The replacement drive must be the same model as the drive that you are replacing Also the disk must be completely empty with no data and no partition tabl...

Page 15: ...When it is safe to remove the drive the state will change to Decommissioned Important Do not remove drives in the Decommissioning state If the drive never reaches the Decommissioned state contact Qua...

Page 16: ...de replacement remove all of the drives If you are returning a faulty drive record the serial number for return purposes 3 1 1 3 Installing a 3 5 inch drive To install a replacement 3 5 inch drive 1 P...

Page 17: ...line retry the replacement process or contact Quantum Corporation Support 3 1 2 Replacing 2 5 inch drives Table 3 6 2 5 inch drive replacement overview 3 1 2 1 Removing a 2 5 inch drive To remove the...

Page 18: ...or more information about drive states refer to the ActiveScale OS Administrator Guide If the status is Degraded the drive has displayed problematic behavior and will undergo automatic repair If the p...

Page 19: ...overview 3 1 3 1 Removing a P100E3 Node PSU To remove the P100E3 node PSU 1 Unplug the AC power cord from the faulty PSU 2 Press the release lever in towards the handle to release the PSU 3 Grasp the...

Page 20: ...n for example because it has failed skip this step Important Do not shut down a node unless all other nodes are healthy Figure 3 8 Resources Rack Node Shutdown a Click Resources b On multi site system...

Page 21: ...have to decommission the drives 3 Remove the 2 5 inch drives from the P100E3 Node For more information refer to Removing a 2 5 inch drive on page 15 4 Remove the 3 5 inch drives from the P100E3 Node F...

Page 22: ...rporation support is not onsite contact customer support for the final post replacement procedures for bringing the P100E3 Node online 3 2 Mounting kit replacement instructions ActiveScale systems can...

Page 23: ...ort Guide 21 3 Align the mounting kit left rail with the rack rear vertical rail 4 Press the tab marked PUSH to secure the rail to the rack Repeat these steps to install the right mounting kit rail 5...

Page 24: ...ully configured Non operating Operating Altitude 984 ft to 39 371 ft 300 m to 12 000 m 984 ft to 10 000 ft 300 m to 3 048 m Height in rack units U Base configuration 3U Power requirements typical maxi...

Page 25: ...bs 26 3 kg 29 lbs 13 1 kg Weight total for all P100E3 Nodes 348 lbs 157 8 kg 174 lbs 118 38 kg Table 4 11 12 TB hard disk drive specification summary Condition Specification Model Ultrastar He12 Capac...

Page 26: ...art number 1EX1892 Replacement parts N A Replacement part number includes drive carrier drive and screws Type SAS 1 Only hot swappable after decommissioning Table 4 13 480 GB solid state drive specifi...

Page 27: ...ActiveScale P100E3 Support Guide 25...

Page 28: ...assistance contact the Quantum Corporation Support Center Region Support Contact North America 1 800 284 5101 toll free 1 720 249 5700 EMEA 1 800 7826 8888 toll free 49 6131 324 185 Asia Pacific 800 7...

Reviews: