Your Quantum heater is a completely sealed refrigeration system, similar to a household
refrigerator. The maintenance program to be employed on your Quantum is not much different to
that required for the maintenance of a standard electric water heater. However, the Quantum
warranty may be void if any of the following conditions are not
met
or if the refrigeration lines
or components are damaged or altered in any unauthorised way.
5a: Air Evaporator Coils
It is important that the air inlet and outlet vents are kept clear
. Restriction of air-inlet or outlet
vents may void warranty if the system has been damaged due to insufficient airflow. The Fin coil
must be checked regularly and any debris build up (such as leaves etc) removed.
The system uses an evaporator coil to extract heat from the air. The coil is extremely efficient in
warm humid weather; however, as temperatures drop to ten degrees or less the coil will begin to
collect ice. The coil has been designed with "heat injection" for defrosting. During the "heat
injection" process the fan may turn off, this is normal as the pool & building heaters are designed
to fight ice build up, in cold or freezing weather.
5b: Special Note On Heat Exchanger
The heat exchanger
MUST
be installed before (up stream from) the sanitisation system not after
(down stream) – see figures 3 & 4. This is to avoid high concentrations of sanitiser being passed
through the heat exchanger, which may corrode it and void the warranty.
SERVICE CAUTION
Before any electrical components are inspected
the System MUST
be turned off
at the power
point / mains supply. Do not touch wiring or any electrical components without supervision or
training to Australian (or equivalent) standards.