Quantum Pure Aire LC - 5500 Owner'S Manual Download Page 4

Contaminant Level

Contaminant Status

High

Medium

Low

1

5

10

MANUAL

AUTO

Contaminant Neutralize

Contaminant Present

03 Active

OFF

ON

Light Commercial

control

 

panel

 

for

 

light

 

commercial

 

with

 

sensor

1. 

Contaminant Neutralized

: This Green Light indicates that the 

    contaminants are neutralized and the sensor is in standby mode.
    In this mode, the fan will run continuously and the unit will monitor the 
    levels of impurities in the air.  When the air contains very little or no 
    contaminant the light remains on. 

NOTE

:  when the unit is first turned on,

    this light will blink on and off for about 3 minutes as the unit warms up. 
    It will remain ON when the unit is ready to operate.
2. 

Contaminant Present

: This Red Light indicates the presence of sufficient 

     impurities in the air to signal the system to begin the cleaning process.
3. 

O3 Active

: This Green Light will turn ON whenever ozone is generated.

4. 

Contaminant Levels

: These Yellow Lights indicate the levels of impurities

    as HIGH, MEDIUM & LOW. When the purification process is complete, 
    all Yellow  Lights will turn off.
5. 

ON/OFF Control Knob

: This Knob must be in the ON position to operate

    the unit in either mode.
6. 

Auto/Manual Control Knob

: You have a choice of one of two modes. 

   
    

Auto Mode

: In this mode, the unit will operate under the control of the 

   

puri-stat. The air quality will be monitored and treated by the unit  

    automatically. 
    

Manual Mode

: In this mode, the unit will by-pass the sensor 

    circuit and

 

allows the user to operate the unit manually. By turning this 

    knob clockwise

the fan speed is decreased.

    

NOTE: 

On this mode the unit will generate ozone continuously.

UNDERSTANDING HOW YOUR UNIT WORKS

control

 

panel

 

for

 

light

 

commercial

 

with

 

out

 

sensor

air treatment system

with puri-

Light Commercial

air treatment system

POWER ON

03 Active

   

1  

 2

  

  

3

  

  

4

  

 5

    6   7   8

   

9

   

1

0

    

    

  

OFF

ON

UNDERSTANDING HOW YOUR UNIT WORKS

 

1.  

On / Off knob

:  Turning the knob clockwise to the ON position will turn

     the machine on. Turning this knob clockwise will also control the fan speed.
     A higher speed will  produce more Ozone. 
2.  

O3 Active

: This green light will turn ON to indicate that Ozone is 

     generated.
3.  

Power On:

  This Red light will remain on when the machine is operating

    Ozone

1. Place your air purifier at counter height or higher. This placement will give
   you the best possible results. This is an electrical device. To reduce the risk
   of electric shock, never plug the air purifier into an outlet while your hands
   are wet. Never expose to rain or place the unit in standing water.
2. Plug the AC power cord to an 110Vac or 240Vac outlet.
3. Place unit at least 3" to 6" from a wall or bulkhead, this allows for proper
    ventilation.
4. Chose Auto or Manual Mode 
5. Turn the unit ON by turning the ON/OFF Control Knob  to the ON position.
    

NOTE:

 If Manual mode is selected, then fan speed control will be available.

HOW TO OPERATE

Page -4-

Page -5-

Summary of Contents for LC - 5500

Page 1: ...unit and the AC adapter prepaid to the address below It is recommended that the RA be prominently placed on the outside of the shipping carton Failure to follow these steps may lead to unnecessary delay and expense in processing your request If the unit is beyond the warranty period we will repair retrofit or otherwise return the unit to an operational state You will be given the cost of the repai...

Page 2: ...or Sales Dept Units must be returned within thirty 30 days of date received All returned merchandise must be in excellent condition or a fee will be assessed Freight charges are non refundable on any returned or refused delivery Refunds will be issued approximately ten 10 days after unit is received in our facility Failure to follow these steps may lead to unnecessary delay and expense in processi...

Page 3: ...cases the area being treated may require additional cleaning methods as well as operating the unit Page 6 Page 3 An Ozone AirTreatment System Ozone is a very powerful oxidant that is produced naturally It is created in the stratosphere by ultraviolet rays from the sun reacting with oxygen The Ozone Layer The resultant photochemical process forms ozone Ozone protects us from exposure to the harmful...

Page 4: ...ll be monitored and treated by the unit automatically Manual Mode In this mode the unit will by pass the sensor circuit and allows the user to operate the unit manually By turning this knob clockwise the fan speed is decreased NOTE On this mode the unit will generate ozone continuously UNDERSTANDING HOW YOUR UNIT WORKS control panel for light commercial with out sensor air treatment system with pu...

Reviews: