780B Video Generator/Analyzer
– User Guide
Page 194
December 1, 2014
Revision A7
4. Connect the 780B to your host PC via an RS-232 cable.
You will have to use a standard RS-232 cable.
12.4
Procedures for Entering Commands
Use the following procedure to connect to the 780B through the USB port.
1. Open up a terminal program such as Hyperterm on your Windows PC. Configure the terminal session with
the following settings:
Bits per second = 2400, 4800 or 9600
Data bits = 8
Parity = none
Stop bits = 1
Flow control = Hardware
2. Press the Return key on your PC and you should receive the
R:\>
prompt.
Now you are ready to enter commands.
3. Use the following tables as a guideline for enter commands.
Note:
Changes you make through the command line will not be reflected on the 780B touch panel. For
example if you make a selection through the touch panel for the signal type, format and pattern and then
override these changes through the command line, the 780B touch screen will still show the selections you
made through the touch screen but the interface, format and pattern selections you made through the
command line will be active.
Table 11-1 below provides the list of commands supported or testing HDMI sink devices:
Note:
The commands are not case sensitive.
Table 11-1: List of Commands (alphabetical)
– For Testing HDMI Sink Devices
Command
Description
Syntax
Parameters
Command Example
ACRG
Enables or disables
(“Gates” on or off) the
ACR packets sent to a
sink.
ACRG
0, 1
ASSG?
<0, 1>
Where
1, 0
are one of:
0 – disable
1 - enable
To disable ACR packets:
ACRG 0
ALLU
ALLU
Activates a change to
the video output.
ALLU
Not applicable
To load and invoke a format
load command:
FMTL 1080i60
ALLU
ASSG
Enables or disables
adding composite sync
to all three analog
components.
ASSG
R, G, B
ASSG?
<R, G, B>
Where
R, G, B
are one of:
0 – disable
1 - enable
To enable composite sync on
green:
ASSG 0, 1, 0
FMTU
ASSS
Sets or queries the
analog sync signal
swing.
ASSS
<swing>
ASSS?
Where
swing
is between the
range of:
min = 0.000 volts
max = 0.500 volts
To set the analog sync signal
swing:
ASSS 0.286
ALLU
Summary of Contents for 780B
Page 1: ...780B Video Generator Analyzer User Guide Rev A7...
Page 72: ...780B Video Generator Analyzer User Guide Page 71 December 1 2014 Revision A7...
Page 106: ...780B Video Generator Analyzer User Guide Page 105 December 1 2014 Revision A7...
Page 126: ...780B Video Generator Analyzer User Guide Page 125 December 1 2014 Revision A7...
Page 183: ...780B Video Generator Analyzer User Guide Page 182 December 1 2014 Revision A7...
Page 191: ...780B Video Generator Analyzer User Guide Page 190 December 1 2014 Revision A7...