7. Troubleshooting
Error
Possible cause
Error correction
The unit
does not
start
No mains connection
No water in the tank
Thermostat is disconnected
Thermostat does not close circuit
Starting device at the compressor is
defect
Interference of the compressor
(interwinding fault)
Establish main connection
(plug the unit)
Fill in water
Switch on the Thermostat
Change the Thermostat
Exchange the starting
device (relay and
condenser)
Change the compressor
Unit is
running,
but does
not cool
The condenser is blocked with dirt
Failure of the condenser fan
Leakage in the refrigeration system
Compressor interference
Clean the condense
Exchange the fan
Repair the leakage,
evacuate gas, and fill with
the refrigerant gas
(R134a)
Exchange the compressor
Unit does
not switch
off
Thermostat defect
Leakage in the refrigeration system
Cooling demand is to large
Exchange Thermostat
Repair the leakage, and fill with
the refrigerent (R134a)
Control the cooling
demand and if necessary
reduce the cooling load
All these works have to be carried out by skilled and qualified personnel!
Should it not be possible to take care of the failure, please contact the responsible
service.
8. Noise emission
70 dB (A) data according to EN 292 part 2 A1
At level, which are lower as or equal 70 dB (A), the inscription "70 dB (A)" is adequate.