![Quanser QNET User Manual Download Page 8](http://html2.mh-extra.com/html/quanser/qnet/qnet_user-manual_3444397008.webp)
4
SPECIFICATIONS
The specifications of the MYOELECTRIC trainer are given in Table 2.
Symbol
Description
Value
Unit
Servo Motor:
Operating Range
4.8-6.0
V
M
H
Stall torque
3
kg
·
cm
Diemsions
29 x 13 x 30
mm
3
m
s
Weight
0.02
kg
EMG Sensor:
Analog output range
±
5
V
Gain
300
V/V
Upper cut-off frequency
500
Hz
Lower cut-off frequency
25
Hz
Common mode rejection ratio
80
dB
Supply voltage (typical)
5.00
V
Isolation Amplifier:
V
M AX
Recommended input voltage (accurate and linear)
±
0.200
V
|
V
IN
|
M AX
Maximum differential input voltage
0.308
V
G
Gain
8
V/V
V
OL
Output low voltage
1.29
V
V
OH
Output high voltage
3.8
V
Bandwidth
100
kHz
Supply Voltage
5.5
V
Table 2: MYOELECTRIC specifications
QNET MYOELECTRIC- User Manual
8