Quanser AMPAQ-PWM User Manual Download Page 2

© 2016 Quanser Inc., All rights reserved.

Quanser Inc.
119 Spy Court
Markham, Ontario
L3R 5H6
Canada
[email protected]
Phone: 1-905-940-3575
Fax: 1-905-940-3576

Printed in Markham, Ontario.

For more information on the solutions Quanser Inc. offers, please visit the web site at:

http://www.quanser.com

This document and the software described in it are provided subject to a license agreement. Neither the software nor this document may be
used or copied except as specified under the terms of that license agreement. All rights are reserved and no part may be reproduced, stored in
a retrieval system or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior
written permission of Quanser Inc.

Waste Electrical and Electronic Equipment (WEEE)

This symbol indicates that waste products must be disposed of separately from municipal household waste, according to Directive
2002/96/EC of the European Parliament and the Council on waste electrical and electronic equipment (WEEE). All products at the
end of their life cycle must be sent to a WEEE collection and recycling center. Proper WEEE disposal reduces the environmental
impact and the risk to human health due to potentially hazardous substances used in such equipment. Your cooperation in proper
WEEE disposal will contribute to the effective usage of natural resources. For information about the available collection and
recycling scheme in a particular country, go to

ni.com/citizenship/weee

.

电子信息产品污染控制管理办法

 

(中国

 

RoHS

中国客户

  

Na

ti

onal Instruments 

符合中国电子信息产品中限制使用某些有害物质命令

 

RoHS

)。

关于

Na

ti

onal Instruments 

中国

 

RoHS

合规性信息,请登录

 

ni.com/environment/rohs_china

 

(For informa

ti

on about China RoHS compliance, go to ni.com/environment/rohs_china)

 

This product meets the essential requirements of applicable European Directives as follows:

• 2006/95/EC; Low-Voltage Directive (safety)

• 2004/108/EC; Electromagnetic Compatibility Directive (EMC)

FCC NOTICE

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Industry Canada Notice

This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

AMPAQ-PWM User Manual

2

Summary of Contents for AMPAQ-PWM

Page 1: ...USER MANUAL AMPAQ PWM Amplifier Set Up and Configuration CAPTIVATE MOTIVATE GRADUATE...

Page 2: ...cycle must be sent to a WEEE collection and recycling center Proper WEEE disposal reduces the environmental impact and the risk to human health due to potentially hazardous substances used in such eq...

Page 3: ...escription 4 2 Components 5 3 Specifications 7 4 Fuse Installation 8 5 Wiring Procedure 10 5 1 Cable Nomenclature 10 5 2 Typical Connections 11 6 Troubleshooting 12 7 Technical Support 12 AMPAQ PWM Us...

Page 4: ...ace for increased flexibility current sensing capability and an auxiliary E Stop connector to allow a single E Stop button to stop multiple devices Figure 1 1 Quanser AMPAQ PWM Caution This equipment...

Page 5: ...ibration status of the connected device i e Shake Table II 6 E Stop connector The AMPAQ PWM requires an E Stop emergency stop button to be connected If no E Stop button is connected the AMPAQ PWM is d...

Page 6: ...a Front b Back Figure 2 1 AMPAQ PWM components a Front b Back Figure 2 2 AMPAQ PWM analog and digital sensor connectors AMPAQ PWM User Manual 6...

Page 7: ...ing 3 75 A Fuses 3 5 A 250 V 3AG Slow Blow Protection Class Class I Table 3 1 AC Input Specifications PWM Output Specifications Value Maximum Continuous Output Current 3 75 A Maximum Peak Output Curre...

Page 8: ...to prevent premature thermal shutdown of the amplifier Caution Do not position the equipment so that it is difficult to operate the on off switch Caution The AMPAQ PWM devices are made to be used wit...

Page 9: ...holders and insert the new ones Figure 4 2 Replacing the fuse in the fuse holder 5 Ensure the fuse being installed is a 3 5 A 250 V 3AG Slow Blow fuse For example the following fuses are acceptable r...

Page 10: ...AMPAQ PWM to the desired load c E Stop E Stop The E Stop must be connected to the AMPAQ PWM for proper operation The E Stop button locks in the dis abled position when pressed To release the E Stop t...

Page 11: ...n Ca ble This cable connects the Digital I O connector on the AMPAQ PWM to a Q2 USB or QPIDe terminal board h Split Digital I O Cable Split 16 pin Ribbon Cable This cable connects the Digital I O conn...

Page 12: ...he User Manual for that Quanser product have been made correctly If the Emergency stop switch is connected to the amplifier make sure the red button is in the upper position to enable the amplifier Th...

Page 13: ...range of control peripherals includes amplifiers and data acquisition boards They can be purchased separately to control educational or research grade plants Mix and match these peripherals with Quan...

Reviews: