MITX-DNV0 Series - User Guide, Rev. 1.2
www.quanmax.com
// 75
Figure 51: BIOS Advanced Menu - Serial Port Console Redirection - Out-of-Band Mgmt Port Console Redirection
Settings
BIOS SETUP UTILITY
Main
Advanced
Power
Boot
Security
Save & Exit
Out-of-Band Mgmt Port
[COM1]
Terminal Type
[VT-UTF8]
Bits per second
[115200]
→
←
: Select Screen
Flow Control
[None]
↑
↓
: Select Item
Data Bits
8
Enter: Select
Parity
None
+/-: Change Opt.
Stop Bits
1
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save & Exit
ESC: Exit
Version 2.19.1266. Copyright (C) 2018, American Megatrends, Inc.
Feature
Option
Description
Out-of-Band Mgmt
Port
[COM1], [COM2]
Select a COM port for Out-of-Band Management Port. Microsoft
Windows Emergency Management Services (EMS) allows
remote management of a Windows Server OS through a serial
port.
Terminal Type
[VT100], [VT100+],
[VT-UTF8], [ANSI]
Determine the terminal type. VT-UTF8 is the preferred terminal
type for out-of-band management. The next best choice is
VT100+ and then VT100.
Bits per second
[9600], [19200],
[57600], [115200]
Select serial port transmission speed. The speed must be
matched on the other side. Long or noisy lines may require
lower speeds.
Flow Control
[None], [Hardware
RTS/CTS], [Software
Xon/Xoff]
Flow control can prevent data loss from buffer overflow. When
sending data, if the receiving buffers are full, a 'stop' signal can
be sent to stop the data flow. You may select “None”, “Hardware
RTS/CTS” or "Software Xon/Xoff" depending on the
circumstances.