MOUNTING INFORMATION
The CubicSecure must be installed by a
plumber according to the Safe Water
Installation industry regulations.
Security systems such as residential sprinklers
and emergency cooling of solid fuel boilers or
similar must be connected before the device. If
they are installed afterwards, they risk running
out of water supply.
Install the device after supplying security
systems that require water.
Water filters that are backwashed should be
connected first so that their function is not
disturbed. The system prevents water damage
that may occur after the location of the device.
When installing metal pipes in the distributor
cabinet, the pipe must be provided with an
electrical protective equalization (earthing) which
must be installed by a qualified electrician if
there is not already an earth screw in the
cabinet.
To avoid scalding in apartments, two
CubicSecures can be paired. Pairing provides a
synchronized automatic shut-off between the
hot and cold water lines.
MOUNTING STEPS
1. Install the device on the incoming
water line directly after the water
meter’s shut-off valve and any
non-return valve.
2. Tighten connections without
damaging the plastic casing of the
device.
Correct installation of the device. The arrows
show the direction of water flow.
TIP!
The device is equipped with a counterhold
on the underside. Use an adjustable wrench on
the counterhold. It is also possible to use a
screwdriver in the slot to create a counterhold.
The device and incoming water line, (G20
Eurocone G20).
Details are subject to change, check the latest version
.
The company is not liable for possible errors and/or misprints.
4 of 11