Quandify CubicSecure LTCS01 User Manual & Datasheet Download Page 4

MOUNTING INFORMATION

The CubicSecure must be installed by a
plumber according to the Safe Water
Installation industry regulations.

Security systems such as residential sprinklers
and emergency cooling of solid fuel boilers or
similar must be connected before the device. If
they are installed afterwards, they risk running
out of water supply.

Install the device after supplying security
systems that require water.

Water filters that are backwashed should be
connected first so that their function is not
disturbed. The system prevents water damage
that may occur after the location of the device.

When installing metal pipes in the distributor
cabinet, the pipe must be provided with an
electrical protective equalization (earthing) which
must be installed by a qualified electrician if
there is not already an earth screw in the
cabinet.

To avoid scalding in apartments, two
CubicSecures can be paired. Pairing provides a
synchronized automatic shut-off between the
hot and cold water lines.

MOUNTING STEPS

1. Install the device on the incoming

water line directly after the water
meter’s shut-off valve and any
non-return valve.

2. Tighten connections without

damaging the plastic casing of the
device.

Correct installation of the device. The arrows

show the direction of water flow.

TIP!

The device is equipped with a counterhold

on the underside. Use an adjustable wrench on

the counterhold. It is also possible to use a

screwdriver in the slot to create a counterhold.

The device and incoming water line, (G20

Eurocone G20).

Details are subject to change, check the latest version

here

.

The company is not liable for possible errors and/or misprints.

4 of 11

Summary of Contents for CubicSecure LTCS01

Page 1: ...h that protects against leaks by continuously measuring water consumption water pressure and temperature The device alarms for both micro leakages and larger leaks When the device detects a leak it automatically shuts off the water flow The device can be installed in villas terraced houses and apartments ...

Page 2: ...ON OFF LED 6 CONNECT LED 7 LEAKAGE ALARMS 7 BUTTONS INDICATIONS 8 FUNCTION CHECK 8 WATER SHUT OFF CHECK 8 MICRO LEAKAGE DETECTION CHECK 8 LEAKAGE DETECTION CHECK 8 ACKNOWLEDGE ALARMS 9 DISABLE LEAKAGE DETECTION 9 RESET Wi Fi 9 FACTORY RESET 9 OPERATION 9 SERIAL NUMBER 9 TECHNICAL DATA 10 MAINTENANCE WARRANTY SERVICE 11 Details are subject to change check the latest version here The company is not ...

Page 3: ...duct needs to be connected to Wi Fi When the device is connected you can control CubicSecure remotely through our app CubicSecure is developed and manufactured in Sweden with advanced technology for water measurement INSTALLATION INFORMATION CubicSecure is a small device that is easy to install in tight spaces The device is easily mounted on main incoming water pipes in a villa or apartment The de...

Page 4: ...earthing which must be installed by a qualified electrician if there is not already an earth screw in the cabinet To avoid scalding in apartments two CubicSecures can be paired Pairing provides a synchronized automatic shut off between the hot and cold water lines MOUNTING STEPS 1 Install the device on the incoming water line directly after the water meter s shut off valve and any non return valve...

Page 5: ...e CubicSecures One for hot water and one for cold water 2 Hold down the CONNECT button for 5 seconds on the device installed for cold water The CONNECT LED starts flashing YELLOW and BLUE 3 Hold down the CONNECT button for 5 seconds on the device installed for hot water The CONNECT LED starts flashing YELLOW and RED You can also press once on CONNECT to switch the hot cold water designation 4 Make...

Page 6: ... has closed the valve in the meantime This process takes up to one minute after which the device opens the valve again RED The device is not working properly Contact technical support WATER ON OFF LED LED PATTERN LED MEANING ACTION OFF The valve is closed The water supply flow is off Turn on water supply by pressing WATER ON OFF WHITE The valve is open The water supply is on WHITE flashing Indicat...

Page 7: ...Hot cold water pairing has been successful and is completed RED flashing No internet or cloud connection Check router firewall or redo app setup LEAKAGE ALARMS LEAKAGE TYPE FLOW RATE l h DESCRIPTION Micro leakage 0 01 Detected by the valve being automatically closed daily to measure a pressure drop above 0 5 bar for a maximum of 45 seconds Medium leakage 6 The device alarms and shuts off the water...

Page 8: ...ap to simulate a very small leak A dripping stream of water will suffice 2 Press the WATER ON OFF button to close the valve When the valve is closed the STATUS LED will flash GREEN while the pressure sensor scans for small leaks for about 45 seconds If the pressure sensor manages to find a leak the STATUS LED starts flashing YELLOW If the pressure sensor does not find a leak redo the steps with a ...

Page 9: ... FACTORY RESET 1 Firstly insert a paperclip into the hole on the reset button while plugging in the power cable for 3 seconds 2 Wait for about three minutes After about three minutes the device has reset and the LEDs light up again Note that you will lose applied firmware updates and hot cold pairings when doing a factory reset OPERATION You can access the device data such as water usage temperatu...

Page 10: ...ed 0 5 bar pressure loss approx 0 01 l h Medium sized leakage detected 6 l h for at least 45 minutes Large leakage detected 1500 l h for at least 90 seconds Weight 720 grams Dimensions 71 mm height 85 mm width length 110 mm Power supply 5VDC 2A Power supply micro USB cable EU plug 1m cable Average device power usage 6 kWh year Wi Fi on Default transmission resolution 1 hour Valve open close time 1...

Page 11: ...eriod for replacement or repair of a product or spare part does not exceed the liability period for the original product Quandify is not responsible for faults resulting from accidents incorrect installation liquid damage incorrect care abuse or other irregular use Quandify is not responsible for any loss or damage caused by a non functioning product Its responsibility is strictly limited to the r...